Contact‐Free Screening of Atrial Fibrillation by a Smartphone Using Facial Pulsatile Photoplethysmographic Signals
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Background: We aimed to evaluate a novel method of atrial fibrillation ( AF ) screening using an iP hone camera to detect and analyze photoplethysmographic signals from the face without physical contact by extracting subtle beat‐to‐beat variations of skin color that reflect the cardiac pulsatile signal. Methods and Results: Patients admitted to the cardiology ward of the hospital for clinical reasons were recruited. Simultaneous facial and fingertip photoplethysmographic measurements were obtained from 217 hospital inpatients (mean age, 70.3±13.9 years; 71.4% men) facing the front camera and with an index finger covering the back camera of 2 independent iP hones before a 12‐lead ECG was recorded. Backdrop and background light intensity was monitored during signal acquisition. Three successive 20‐second (total, 60 seconds) recordings were acquired per patient and analyzed for heart rate regularity by Cardiio Rhythm (Cardiio Inc, Cambridge, MA ) smartphone application. Pulse irregularity in ≥1 photoplethysmographic readings or 3 uninterpretable photoplethysmographic readings were considered a positive AF screening result. AF was present on 12‐lead ECG in 34.6% (n=75/217) patients. The Cardiio Rhythm facial photoplethysmographic application demonstrated high sensitivity (95%; 95% confidence interval, 87%–98%) and specificity (96%; 95% confidence interval, 91%–98%) in discriminating AF from sinus rhythm compared with 12‐lead ECG . The positive and negative predictive values were 92% (95% confidence interval, 84%–96%) and 97% (95% confidence interval, 93%–99%), respectively. Conclusions: Detection of a facial photoplethysmographic signal to determine pulse irregularity attributable to AF is feasible. The Cardiio Rhythm smartphone application showed high sensitivity and specificity, with low negative likelihood ratio for AF from facial photoplethysmographic signals. The convenience of a contact‐free approach is attractive for community screening and has the potential to be useful for distant AF screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388 · cited 10×
“DOI: 10.1161/JAHA.118.008585 Journal of the American Heart Association 6 Contact-Free Screening of Atrial Fibrillation Yan et al O R IG IN A L R E S E A R C H sphygmomanometers have a pooled sensitivity of 98% and specificity of 92%, whereas non–12-lead ECGs have a sensitivity of 91% and a specificity of 95% in detect…”
BackgroundInfluential2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Prevalence, incidence and lifetime risk of atrial fibrillation: the Rotterdam study
Heeringa, J., van der Kuip, D. A. M., Hofman, A., Kors, J. A., van Herpen, G., Stricker, B. H. C., Stijnen, T., Lip, G. Y. H., & Witteman, J. C. M. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi825 · Cited by 1,939 · cited 1×
“Prevalence of AF sharply increases with age, and with our rapidly aging population, prevalence of AF is expected to double by 2060.(2,3) Cardioembolic stroke is one of the most common complications of AF, and at least 1 in 3 strokes is directly attributable to AF.”
BackgroundGlobal epidemiology of atrial fibrillation
Rahman, F., Kwan, G. F., & Benjamin, E. J. (2014) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.118 · Cited by 731
Lowres, N., Neubeck, L., Salkeld, G., Krass, I., McLachlan, A. J., Redfern, J., Bennett, A. A., Briffa, T., Bauman, A., Martinez, C., et al. (2014) · Thrombosis and Haemostasis · doi:10.1160/th14-03-0231 · Cited by 458
Hobbs, F., Fitzmaurice, D., Mant, J., Murray, E., Jowett, S., Bryan, S., Raftery, J., Davies, M., & Lip, G. (2005) · Health Technology Assessment · doi:10.3310/hta9400 · Cited by 437 · cited 1×
“Pulse palpation has a sensitivity of 92% but only a modest specificity of 82%, which means more false-positive results.(26) A recent systematic review and meta-analysis found that modified Table 1.”
BackgroundLau, J. K., Lowres, N., Neubeck, L., Brieger, D. B., Sy, R. W., Galloway, C. D., Albert, D. E., & Freedman, S. B. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.220 · Cited by 326
McManus, D. D., Lee, J., Maitas, O., Esa, N., Pidikiti, R., Carlucci, A., Harrington, J., Mick, E., & Chon, K. H. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2012.12.001 · Cited by 253
Chan, P., Wong, C., Poh, Y. C., Pun, L., Leung, W. W., Wong, Y., Wong, M. M., Poh, M., Chu, D. W., & Siu, C. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.116.003428 · Cited by 240 · cited 3×
“Recently, several studies have reported the use of smartphone cameras to differentiate between AF and sinus rhythm using fingertip photoplethysmographic signals.(16,28,29) In a study by McManus et al, fingertip photoplethysmographic signal recorded using an iPhone 4S in 76 patients before and after cardioversion had a…”
BackgroundMethodSelf-citationPULSE‐SMART: Pulse‐Based Arrhythmia Discrimination Using a Novel Smartphone Application
McMANUS, D. D., CHONG, J. W., SONI, A., SACZYNSKI, J. S., ESA, N., NAPOLITANO, C., DARLING, C. E., BOYER, E., ROSEN, R. K., FLOYD, K. C., et al. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12842 · Cited by 156
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
How to use digital devices to detect and manage arrhythmias: an EHRA practical guide
Svennberg, E., Tjong, F., Goette, A., Akoum, N., Di Biase, L., Bordachar, P., Boriani, G., Burri, H., Conte, G., Deharo, J. C., et al. (2022) · Europace · doi:10.1093/europace/euac038 · Cited by 261
High-Throughput, Contact-Free Detection of Atrial Fibrillation From Video With Deep Learning
Yan, B. P., Lai, W. H. S., Chan, C. K. Y., Au, A. C. K., Freedman, B., Poh, Y. C., & Poh, M.-Z. (2020) · JAMA Cardiology · doi:10.1001/jamacardio.2019.4004 · Cited by 94
Self-citationMobile health applications for the detection of atrial fibrillation: a systematic review
Lopez Perales, C. R., Van Spall, H. G. C., Maeda, S., Jimenez, A., Laţcu, D. G., Milman, A., Kirakoya-Samadoulougou, F., Mamas, M. A., Muser, D., & Casado Arroyo, R. (2021) · EP Europace · doi:10.1093/europace/euaa139 · Cited by 77
“6% in a 70 years old Chinese population.(21) The AliveCor device had a sensitivity from 64.”
Background
Metadata
- Authors
- Yan, B. P., Lai, W. H. S., Chan, C. K. Y., Chan, S. C., Chan, L., Lam, K., Lau, H., Ng, C., Tai, L., Yip, K., To, O. T. L., Freedman, B., Poh, Y. C., & Poh, M.
- Venue
- Journal of the American Heart Association
- Published
- 2018-04-17
- Volume
- 7
- Issue
- 8
- ISSN
- 2047-9980 (ISSN-L)
- OpenAlex
- W2796199091
- Cited by
- 110
- References
- 12
- FWCI
- 5.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contact‐Free Screening of Atrial Fibrillation by a Smartphone Using Facial Pulsatile Photoplethysmographic Signals. https://app.cochat.ai/papers/10.1161/jaha.118.008585
- The paper
- Yan, B. P., Lai, W. H. S., Chan, C. K. Y., Chan, S. C., Chan, L., Lam, K., Lau, H., Ng, C., Tai, L., Yip, K., To, O. T. L., Freedman, B., Poh, Y. C., & Poh, M. (2018). Contact‐Free Screening of Atrial Fibrillation by a Smartphone Using Facial Pulsatile Photoplethysmographic Signals. Journal of the American Heart Association. https://doi.org/10.1161/jaha.118.008585
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.