Deep Learning–Based Algorithm for Detecting Aortic Stenosis Using Electrocardiography
Open accessAbstract
Background: Severe, symptomatic aortic stenosis ( AS ) is associated with poor prognoses. However, early detection of AS is difficult because of the long asymptomatic period experienced by many patients, during which screening tools are ineffective. The aim of this study was to develop and validate a deep learning–based algorithm, combining a multilayer perceptron and convolutional neural network, for detecting significant AS using ECGs. Methods and Results: This retrospective cohort study included adult patients who had undergone both ECG and echocardiography. A deep learning–based algorithm was developed using 39 371 ECG s. Internal validation of the algorithm was performed with 6453 ECG s from one hospital, and external validation was performed with 10 865 ECG s from another hospital. The end point was significant AS (beyond moderate). We used demographic information, features, and 500‐Hz, 12‐lead ECG raw data as predictive variables. In addition, we identified which region had the most significant effect on the decision‐making of the algorithm using a sensitivity map. During internal and external validation, the areas under the receiver operating characteristic curve of the deep learning–based algorithm using 12‐lead ECG for detecting significant AS were 0.884 (95% CI, 0.880–0.887) and 0.861 (95% CI, 0.858–0.863), respectively; those using a single‐lead ECG signal were 0.845 (95% CI, 0.841–0.848) and 0.821 (95% CI, 0.816–0.825), respectively. The sensitivity map showed the algorithm focused on the T wave of the precordial lead to determine the presence of significant AS . Conclusions: The deep learning–based algorithm demonstrated high accuracy for significant AS detection using both 12‐lead and single‐lead ECG s.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Valvular and composite SHD AI-ECG models are promising for referral enrichment.
“Valvular and composite SHD models are promising for referral enrichment”
From AI-ECG for Echocardiography Triage in Structural Heart Disease: Evidence, Implementation, and Future Directions (2026) · cites this paper as [20]
The Methods (Statistical Analysis; page unavailable) describe the AI-ECG algorithm as a screen for aortic stenosis before confirmatory echocardiography, supporting its potential to help select patients for referral. The paper studies aortic stenosis, however, and does not support the claim about composite structural heart disease (SHD) models. (LLM, conf=0.87)
Experimental — accuracy not yet measuredKwon et al. independently reported AUCs of 0.884 in internal validation and 0.861 in external validation using a combined multilayer perceptron-convolutional neural network architecture.
“Kwon et al independently reported AUCs of 0.884 in internal validation and 0.861 in external validation using a combined multilayer perceptron–convolutional neural network architecture.20”
From AI-ECG for Echocardiography Triage in Structural Heart Disease: Evidence, Implementation, and Future Directions (2026) · cites this paper as [20]
Valvular disease may produce electrical signatures detectable beyond standard ECG criteria.
“Kwon et al. developed a deep learning algorithm to detect aortic stenosis from ECGs, demonstrating that valvular disease may produce electrical signatures detectable beyond standard ECG criteria [29].”
From Deep Learning Applied to 12-Lead ECGs for Detection of Structural, Metabolic and Systemic Disease (2026) · cites this paper as [29]
A deep learning algorithm detected aortic stenosis from ECGs.
“Kwon et al. developed a deep learning algorithm to detect aortic stenosis from ECGs, demonstrating that valvular disease may produce electrical signatures detectable beyond standard ECG criteria [29].”
From Deep Learning Applied to 12-Lead ECGs for Detection of Structural, Metabolic and Systemic Disease (2026) · cites this paper as [29]
Deep learning has been shown to be beneficial in detecting specific heart diseases from the 12-lead ECG, including aortic stenosis, low LVEF, low left ventricular hypertrophy and composites of valvular diseases.
“The application of deep learning, a subset of artificial intelligence (AI), has been shown to be beneficial in the detection of specific heart diseases from the 12-lead electrocardiogram (ECG). This includes conditions such as aortic stenosis, low left ventricular ejection fraction (LVEF) and low left ventricular hypertrophy, as well as composites of many valvular diseases3,17–21.”
From Detecting structural heart disease from electrocardiograms using AI (2025) · cites this paper as [18]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474 · see citing works
Ensemble methods in machine learning
Dietterich, T. G. (2000) · Lecture Notes in Computer Science · doi:10.1007/3-540-45014-9_1 · Cited by 8,408 · see citing works
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205 · see citing works
Kuhn, M., & Johnson, K. (2013) · doi:10.1007/978-1-4614-6849-3 · Cited by 6,788 · see citing works
Prevalence of Diabetic Retinopathy in the United States, 2005-2008
Zhang, X., Saaddine, J. B., Chou, C.-F., Cotch, M. F., Cheng, Y. J., Geiss, L. S., Gregg, E. W., Albright, A. L., Klein, B. E. K., & Klein, R. (2010) · JAMA · doi:10.1001/jama.2010.1111 · Cited by 1,196 · see citing works
Analysis of machine learning techniques for heart failure readmissions
Mortazavi, B. J., Downing, N. S., Bucholz, E. M., Dharmarajan, K., Manhapra, A., Li, S.-X., Negahban, S. N., & Krumholz, H. M. (2016) · Circulation: Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.116.003039 · Cited by 401 · see citing works
Flagged first, then by citations
Research works printed but not linked: 40
- [1]Kodali SK, Velagapudi P, Hahn RT, Abbott D, Leon MB. Valvular heart disease in patients ≥80 years of age. J Am Coll Cardiol. 2018; 71: 2058– 2072. 29724358
- [2]Carabello BA, Paulus WJ. Aortic stenosis. Lancet. 2009; 373: 956– 966. 19232707
- [3]Lancellotti P, Magne J, Dulgheru R, Clavel M‐A, Donal E, Vannan MA, Chambers J, Rosenhek R, Habib G, Lloyd G, et al. Outcomes of patients with asymptomatic aortic stenosis followed up in heart valve clinics. JAMA Cardiol. 2018; 3: 1060. 30285058 PMC6583052
- [4]Bonow RO. Exercise hemodynamics and risk assessment in asymptomatic aortic stenosis. Circulation. 2012; 126: 803– 805. 22832785
- [6]Ben‐Dor I, Pichard AD, Gonzalez MA, Weissman G, Li Y, Goldstein SA, Okubagzi P, Syed AI, Maluenda G, Collins SD, et al. Correlates and causes of death in patients with severe symptomatic aortic stenosis who are not eligible to participate in a clinical trial of transcatheter aortic valve implantation. Circulation. 2010; 122: S37– S42. 20837923
- [7]Maes F, Lerakis S, Barbosa Ribeiro H, Gilard M, Cavalcante JL, Makkar R, Herrmann HC, Windecker S, Enriquez‐Sarano M, Cheema AN, et al. Outcomes from transcatheter aortic valve replacement in patients with low‐flow, low‐gradient aortic stenosis and left ventricular ejection fraction less than 30%. JAMA Cardiol. 2019; 4: 64. 30566185 PMC6439680
- [8]Baumgartner H, Falk V, Bax JJ, De Bonis M, Hamm C, Holm PJ, Iung B, Lancellotti P, Lansac E, Rodriguez Muñoz D, et al. 2017 ESC/EACTS guidelines for the management of valvular heart disease. Eur Heart J. 2017; 38: 2739– 2791. 28886619
- [9]Saikrishnan N, Kumar G, Sawaya FJ, Lerakis S, Yoganathan AP. Accurate assessment of aortic stenosis. Circulation. 2014; 129: 244– 253. 24421359
- [10]Maganti K, Rigolin VH, Sarano ME, Bonow RO. Valvular heart disease: diagnosis and management. Mayo Clin Proc. 2010; 85: 483– 500. 20435842 PMC2861980
- [11]Alley W, Mahler S. Chapter 54: valvular emergency In: Tintinalli JE, Stapczynski JS, Ma OJ, Yealy DM, Meckler GD, Cline D, eds. Tintinalli's Emergency Medicine: A Comprehensive Study Guide. New York, NY: McGraw Hill Education; 2016; 373– 380.
- [12]LeCun Y, Bengio Y, Hinton G. Deep learning. Nature. 2015; 521: 436– 444. 26017442
- [13]Gulshan V, Peng L, Coram M, Stumpe MC, Wu D, Narayanaswamy A, Venugopalan S, Widner K, Madams T, Cuadros J, et al. Development and validation of a deep learning algorithm for detection of diabetic retinopathy in retinal fundus photographs. JAMA. 2016; 304: 649– 656. 27898976
- [14]Attia ZI, Kapa S, Lopez‐Jimenez F, McKie PM, Ladewig DJ, Satam G, Pellikka PA, Enriquez‐Sarano M, Noseworthy PA, Munger TM, et al. Screening for cardiac contractile dysfunction using an artificial intelligence–enabled electrocardiogram. Nat Med. 2019; 25: 70– 74. 30617318
- [15]Kwon J‐M, Lee Y, Lee Y, Lee S, Park J. An algorithm based on deep learning for predicting in‐hospital cardiac arrest. J Am Heart Assoc. 2018; 7: e008678 DOI: 10.1161/JAHA.118.008678. 29945914 PMC6064911 · DOI · Paper page
- [16]Attia ZI, Noseworthy PA, Lopez‐Jimenez F, Asirvatham SJ, Deshmukh AJ, Gersh BJ, Carter RE, Yao X, Rabinstein AA, Erickson BJ, et al. An artificial intelligence‐enabled ECG algorithm for the identification of patients with atrial fibrillation during sinus rhythm: a retrospective analysis of outcome prediction. Lancet. 2019; 394: 861– 867. 31378392
- [17]Bonow RO, Brown AS, Gillam LD, Kapadia SR, Kavinsky CJ, Lindman BR, Mack MJ, Thourani VH. ACC/AATS/AHA/ASE/EACTS/HVS/SCA/SCAI/SCCT/SCMR/STS 2017 appropriate use criteria for the treatment of patients with severe aortic stenosis. J Am Coll Cardiol. 2017; 70: 2566– 2598. 29054308
- [18]Bengio Y, Courville A, Vincent P. Representation learning: a review and new perspectives. IEEE Trans Pattern Anal Mach Intell. 2013; 35: 1798– 1828. 23787338
- [19]Schmidhuber J. Deep learning in neural networks: an overview. Neural Networks. 2015; 61: 85– 117. 25462637
- [20]Hannun AY, Rajpurkar P, Haghpanahi M, Tison GH, Bourn C, Turakhia MP, Ng AY. Cardiologist‐level arrhythmia detection and classification in ambulatory electrocardiograms using a deep neural network. Nat Med. 2019; 25: 65– 69. 30617320 PMC6784839
- [22]LeCun Y, Boser B, Denker JS, Howard RE, Habbard W, Jackel LD. Handwritten digit recognition with a back‐propagation network. Adv Neural Inf Process Syst. 1990; 1: 396– 404.
- [23]LeCun Y, Bottou L, Bengio Y, Haffner P. Gradient‐based learning applied to document recognition. Proc IEEE. 1998; 1: 2278– 2324.
- [25]Abadi M, Barham P, Chen J, Chen Z, Davis A, Dean J, Devin M, Ghemawat S, Irving G, Isard M, et al. TensorFlow: a system for large‐scale machine learning TensorFlow: a system for large‐scale machine learning. 12th USENIX Symp Oper Syst Des Implement (OSDI ‘16). 2016; 265– 284.
- [26]Pandit SV. ECG baseline drift removal through STFT. In: Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE; 1: 1405– 1406.
- [29]Frizzell JD, Liang L, Schulte PJ, Yancy CW, Heidenreich PA, Hernandez AF, Bhatt DL, Fonarow GC, Laskey WK. Prediction of 30‐day all‐cause readmissions in patients hospitalized for heart failure. JAMA Cardiol. 2017; 2: 204. 27784047
- [30]Selvaraju RR, Cogswell M, Das A, Vedantam R, Parikh D, Batra D. Grad‐CAM: visual explanations from deep networks via gradient‐based localization. Proc IEEE Int Conf Comput Vis. 2017; 1: 618– 626.
- [31]Fawcett T. An introduction to ROC analysis. Pattern Recognit Lett. 2006; 27: 861– 874.
- [32]Carpenter J, Bithell J. Bootstrap confidence intervals: when, which, what? A practical guide for medical statisticians. Stat Med. 2000; 19: 1141– 1164. 10797513
- [33]Russo R, Rizzoli G, Stritoni P, Seminara G, Rubino M, Brumana T. T‐wave changes in patients with hemodynamic evidence of systolic or diastolic overload of the left ventricle: a retrospective study on 168 patients with isolated chronic aortic valve disease. Int J Cardiol. 1987; 14: 137– 143. 2950064
- [34]Xin D, Zheng W, Xuyu J, Yuemin S, Wenjuan Z, Bo B, Xuefang Y, Canliang H. Changes of the electrocardiographic strain pattern in patients with aortic stenosis and its underling mechanisms. Heart. 2011; 97: A239– A240.
- [35]Greve AM, Gerdts E, Boman K, Gohlke‐Baerwolf C, Rossebø AB, Hammer‐Hansen S, Køber L, Willenheimer R, Wachtell K. Differences in cardiovascular risk profile between electrocardiographic hypertrophy versus strain in asymptomatic patients with aortic stenosis (from SEAS Data). Am J Cardiol. 2011; 108: 541– 547. 21624542
- [36]Greve AM, Boman K, Gohlke‐Baerwolf C, Kesäniemi YA, Nienaber C, Ray S, Egstrup K, Rossebø AB, Devereux RB, Køber L, et al. Clinical implications of electrocardiographic left ventricular strain and hypertrophy in asymptomatic patients with aortic stenosis. Circulation. 2012; 125: 346– 353. 22147903
- [37]Hering D, Piper C, Horstkotte D. Influence of atypical symptoms and electrocardiographic signs of left ventricular hypertrophy or ST‐segment/T‐wave abnormalities on the natural history of otherwise asymptomatic adults with moderate to severe aortic stenosis: preliminary communication. J Heart Valve Dis. 2004; 13: 182– 187. 15086255
- [38]Vranic II. Electrocardiographic appearance of aortic stenosis before and after aortic valve replacement. Ann Noninvasive Electrocardiol. 2017; 22: e12457. PMC6931855 28429500
- [39]Xiao HB, Ramzy IS, Bowker TJ, Dancy M. Electrocardiographic associations of right precordial Q waves help to distinguish anterior myocardial infarction from aortic stenosis. Int J Cardiol. 2002; 82: 159– 166. 11853902
- [40]Taniguchi T, Shiomi H, Kosuge M, Morimoto T, Nakatsuma K, Nishiga M, Sasa T, Saito N, Kimura T. Prognostic significance of ST‐segment elevation in leads V1–2 in patients with severe aortic stenosis. Circ J. 2016; 80: 526– 534. 26742587
- [41]Pisano ED, Gatsonis C, Hendrick E, Yaffe M, Baum JK, Acharyya S, Conant EF, Fajardo LL, Bassett L, D'Orsi C, et al. Diagnostic performance of digital versus film mammography for breast‐cancer screening. N Engl J Med. 2005; 353: 1773– 1783. 16169887
- [42]Haug U, Kuntz KM, Knudsen AB, Hundt S, Brenner H. Sensitivity of immunochemical faecal occult blood testing for detecting left‐ vs right‐sided colorectal neoplasia. Br J Cancer. 2011; 104: 1779– 1785. 21559011 PMC3111170
- [43]Schlegel TT, Kulecz WB, Feiveson AH, Greco EC, DePalma JL, Starc V, Vrtovec B, Rahman MA, Bungo MW, Hayat MJ, et al. Accuracy of advanced versus strictly conventional 12‐lead ECG for detection and screening of coronary artery disease, left ventricular hypertrophy and left ventricular systolic dysfunction. BMC Cardiovasc Disord. 2010; 10: 28. 20565702 PMC2894002
- [44]Chen X, Duan Y, Houthooft R, Schulman J, Sutskever I, Abbeel P. InfoGAN: interpretable representation learning by information maximizing generative adversarial nets. Neural Inf Process Syst. 2016; 1: 2172– 2180.
- [45]Fong RC, Vedaldi A. Interpretable explanations of black boxes by meaningful perturbation. Proc IEEE Int Conf Comput Vis. 2017; 1: 3449– 3457.
Cited by
Sorted by citations
Detecting structural heart disease from electrocardiograms using AI
Poterucha, T. J., Jing, L., Ricart, R. P., Adjei-Mosi, M., Finer, J., Hartzel, D., Kelsey, C., Long, A., Rocha, D., Ruhl, J. A., et al. (2025) · Nature · doi:10.1038/s41586-025-09227-0 · Cited by 116 · see citing works
Lee, S., Chu, Y., Ryu, J., Park, Y. J., Yang, S., & Koh, S. B. (2022) · Yonsei Medical Journal · doi:10.3349/ymj.2022.63.s93 · Cited by 88 · see citing works
Self-citationKaur, D., Hughes, J. W., Rogers, A. J., Kang, G., Narayan, S. M., Ashley, E. A., & Perez, M. V. (2024) · Circulation: Heart Failure · doi:10.1161/circheartfailure.123.010879 · Cited by 58 · see citing works
Explaining Deep Learning for ECG Analysis: Building Blocks for Auditing and Knowledge Discovery
Wagner, P., Mehari, T., Haverkamp, W., & Strodthoff, N. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108525 · Cited by 48 · see citing works
Deep-Learning Model for Screening Sepsis Using Electrocardiography
Kwon, J.-M., Lee, Y. R., Jung, M.-S., Lee, Y.-J., Jo, Y.-Y., Kang, D.-Y., Lee, S. Y., Cho, Y.-H., Shin, J.-H., Ban, J.-H., et al. (2021) · Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine · doi:10.1186/s13049-021-00953-8 · Cited by 28 · see citing works
Self-citationLiang, Y., Sau, A., Zeidaabadi, B., Barker, J., Patlatzoglou, K., Pastika, L., Sieliwonczyk, E., Whinnett, Z., Peters, N. S., Yu, Z., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf448 · Cited by 26 · see citing works
Segar, M. W., Lambeth, K. D., Postalian, A., Coulter, S., Gilge, J., Razvi, N., Saeed, M., Paisley, R. D., Pandey, A., & Razavi, M. (2026) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztag018 · Cited by 2 · see citing works
Tang, Q., Deng, K., Cui, Y., Liu, H., & Qian, B. (2026) · International Journal of General Medicine · doi:10.2147/ijgm.s610298
Deep Learning Applied to 12-Lead ECGs for Detection of Structural, Metabolic and Systemic Disease
Shaulian, S., Zeltser, R., & Makaryus, A. N. (2026) · Diagnostics · doi:10.3390/diagnostics16172834
- Authors
- Kwon, J., Lee, S. Y., Jeon, K., Lee, Y., Kim, K., Park, J., Oh, B., & Lee, M.
- Affiliations
- Sejong Institute (KR)
- Sejong General Hospital (KR)
- VUNO Seoul Korea
- Division of Cardiology Cardiovascular Center Incheon Korea
- Corresponding author
- Lee, Soo Youn
- Venue
- Journal of the American Heart Association
- Published
- 2020-04-09
- Volume
- 9
- Issue
- 7
- Pages
- e014717-e014717
- ISSN
- 2047-9980 (ISSN-L)
- PMC
- PMC7428650
- OpenAlex
- W3012755169
- Cited by
- 224
- References
- 6
- Citations by year
- 2026: 23 · 2025: 45 · 2024: 39 · 2023: 36 · 2022: 42 · 2021: 29 · 2020: 10
- FWCI
- 18.09
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Journal of the American Heart Association (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Keywords
- aortic stenosis, electrocardiogram, deep learning, convolutional neural networks, multilayer perceptron, 12-lead ECG, single-lead ECG, early detection, echocardiography, sensitivity maps, T wave, algorithm validation
- MeSH terms
- Deep Learning, Aged, Aged, 80 and over, Aortic Valve, Aortic Valve Stenosis, Electrocardiography, Female, Humans, Male, Middle Aged, Predictive Value of Tests, Retrospective Studies, Severity of Illness Index, Signal Processing, Computer-Assisted, Reproducibility of Results, Early Diagnosis, Republic of Korea
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review