Deep Learning Applied to 12-Lead ECGs for Detection of Structural, Metabolic and Systemic Disease
Open accessAbstract
The 12-lead electrocardiogram (ECG) is inexpensive, noninvasive, and widely available, but conventional interpretation may not capture subtle signals related to cardiac structure, systemic physiology, and future risk. This review examines the use of deep learning–enabled ECG analysis beyond conventional arrhythmia detection and evaluates the maturity, clinical relevance, and implementation challenges of these applications. This narrative review synthesizes landmark studies, external validation cohorts, pragmatic implementation trials, and recent investigations of artificial intelligence–enabled ECG (AI-ECG) models for structural, metabolic, systemic, and prognostic assessment. Particular attention is given to model performance, validation, clinical actionability, and barriers to translation. AI-ECG models have demonstrated the ability to detect reduced left ventricular ejection fraction, hypertrophic cardiomyopathy, valvular disease, cardiac amyloidosis, pulmonary hypertension, hyperkalemia and other dyskalemias, hyperthyroidism, anemia, and sepsis, and to estimate biologic age and mortality risk. Evidence is most mature for screening for reduced left ventricular ejection fraction, supported by large derivation cohorts, external validation, prognostic follow-up, and the EAGLE pragmatic trial. Evidence for many other applications remains retrospective or exploratory, with limitations related to reference standards, generalizability, calibration, disease prevalence, interpretability, and the absence of clearly defined clinical pathways. AI-ECG has the potential to expand the ECG from a conventional diagnostic test into a screening and decision-support platform. Its near-term role is to identify patients who may benefit from confirmatory imaging, laboratory testing, rhythm monitoring, or specialist evaluation. Broader adoption will require prospective validation, workflow integration, subgroup assessment, post-deployment monitoring, regulatory oversight, and evidence that AI-guided care improves outcomes.
AI snapshot
Written from the paper’s full text.
TL;DR
This narrative review surveys deep learning–enabled 12-lead ECG (AI-ECG) applications beyond arrhythmia detection, covering structural, metabolic, systemic, and prognostic targets. It concludes that evidence is most mature for screening reduced left ventricular ejection fraction, while most other applications remain retrospective or exploratory and lack prospective proof of clinical benefit.
Key findings
- Reduced LVEF detection is the most mature application: Attia et al. trained a CNN on >44,000 patients and tested on >52,000, achieving AUC 0.93, sensitivity 86.3%, specificity 85.7%; the EAGLE pragmatic cluster-randomized trial showed AI-guided screening increased new low-ejection-fraction diagnoses within 90 days and targeted echocardiography in AI-positive patients without substantially increasing overall echocardiography use.
- Structural heart disease models show high discrimination: HCM detection AUC 0.96 (sensitivity 87%, specificity 90%), with international external validation AUC 0.922; aortic stenosis screening sensitivity 78% and specificity 74%; cardiac amyloidosis post-development validation AUC 0.84 (lower in Hispanic patients and those with LVH or LBBB).
- Metabolic/systemic models report strong performance: hyperkalemia AUC 0.853–0.883 across validation sites (trained on >1.5 million ECGs from >449,000 patients); point-of-care potassium AUC >0.95 for moderate-to-severe hyperkalemia and >0.85 for hypokalemia; hyperthyroidism AUC 0.926 internal/0.883 external; anemia 0.854/0.824; sepsis 0.901/0.863.
- Prognostic models: one-year all-cause mortality AUC 0.88 overall and 0.85 among ECGs read as normal by physicians; ECG-age >8 years above chronological age was associated with higher mortality, and >8 years younger with lower mortality, even among apparently normal ECGs.
Methods
- Narrative (not systematic) review; targeted literature search of PubMed/MEDLINE and Google Scholar for English-language articles from January 2015 through August 2026, with the final search on 21 August 2026.
- Search combined terms for AI/deep learning/machine learning with ECG terms and condition-specific terms (ventricular dysfunction, heart failure, structural heart disease, HCM, valvular disease, amyloidosis, pulmonary hypertension, hyperkalemia, biologic age, mortality, implementation); reference lists were also screened.
- Priority given to peer-reviewed original studies, external validation studies, prospective/pragmatic implementation studies, and consensus/reporting guidelines; arrhythmia-classification-only studies generally excluded. No formal risk-of-bias assessment or quantitative meta-analysis was performed.
Limitations
- Stated by the paper: as a narrative review, it performed no formal risk-of-bias assessment or meta-analysis; evidence for most applications beyond reduced ejection fraction remains retrospective or exploratory, with limitations in reference standards, generalizability, calibration, disease prevalence, interpretability, and absent defined clinical pathways.
- Stated by the paper: many studies use echocardiographic estimates rather than gold-standard right heart catheterization (pulmonary hypertension) or derive labels from EHR/imaging/billing data, risking selection and verification bias; high discrimination in uncommon conditions does not guarantee high positive predictive value.
- Evident from the text: reported performance metrics are drawn from heterogeneous studies differing in target condition, dataset composition, sample size, preprocessing, and validation strategy, so the review notes performance cannot be directly compared across architectures or studies, and no universally superior architecture is established.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
73 of 116 cited sources checked · 59 supported · 0 flagged · accuracy not yet measured
- Premisecitation
ECG waveforms contain latent signatures of metabolic abnormalities.
“Emerging evidence suggests that ECG waveforms contain latent signatures of ventricular dysfunction [4], structural heart disease [5], metabolic abnormalities [6], and broader physiologic characteristics such as biological age [7] and future mortality risk [8].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [6] Galloway, 2019, Development and Validation of a Deep-Learning Model to Screen for Hyperkalemia From the Electrocardiogram, JAMA Cardiol. source
- Premisecitation
ECG waveforms contain latent signatures of structural heart disease.
“Emerging evidence suggests that ECG waveforms contain latent signatures of ventricular dysfunction [4], structural heart disease [5], metabolic abnormalities [6], and broader physiologic characteristics such as biological age [7] and future mortality risk [8].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [5] Tison, 2019, Automated and Interpretable Patient ECG Profiles for Disease Detection, Tracking, and Discovery, Circ. Cardiovasc. Qual. Outcomes source
- Premisecitation
ECG waveforms contain latent signatures of biological age.
“Emerging evidence suggests that ECG waveforms contain latent signatures of ventricular dysfunction [4], structural heart disease [5], metabolic abnormalities [6], and broader physiologic characteristics such as biological age [7] and future mortality risk [8].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [7] Lima, 2021, Deep Neural Network-Estimated Electrocardiographic Age as a Mortality Predictor, Nat. Commun. source
- Premisecitation
AI-ECG has been applied to point-of-care potassium estimation.
“Later work carried the approach to 12-lead detection of both hypokalemia and hyperkalemia [11] and point-of-care potassium estimation [15].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [15] Lin, 2022, Point-of-Care Artificial Intelligence-Enabled ECG for Dyskalemia: A Retrospective Cohort Analysis for Accuracy and Outcome Prediction, npj Digit. Med. source
- Premisecitation
An AI-ECG model had stable performance across time and demographic subgroups.
“Harmon et al. reported stable performance of an AI-ECG model across time and demographic subgroups, addressing concerns about temporal drift and subgroup bias [20].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [20] Harmon, 2022, Real-World Performance, Long-Term Efficacy, and Absence of Bias in the Artificial Intelligence Enhanced Electrocardiogram to Detect Left Ventricular Systolic Dysfunction, Eur. Heart J.-Digit. Health source
- Premisecitation
An existing AI-ECG algorithm externally validated in a European cohort had good overall discrimination for left ventricular systolic dysfunction.
“König et al. externally validated an existing AI-ECG algorithm in a European cohort and found good overall discrimination for left ventricular systolic dysfunction, although performance was lower in certain subgroups, including patients with tachycardia, atrial fibrillation, or wide QRS complexes [21].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [21] Hohenstein, 2024, Artificial Intelligence-Based Identification of Left Ventricular Systolic Dysfunction from 12-Lead Electrocardiograms: External Validation and Advanced Application of an Existing Model, Eur. Heart J.-Digit. Health source
- Premisecitation
Both human and computerized ECG interpretation may overlook subtle or distributed signals related to cardiac structure, function, and systemic physiology.
“Consequently, both human and computerized interpretation may overlook subtle or distributed signals related to cardiac structure, function, and systemic physiology [5].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [5] Tison, 2019, Automated and Interpretable Patient ECG Profiles for Disease Detection, Tracking, and Discovery, Circ. Cardiovasc. Qual. Outcomes source
- Interpretationcitation
AI-ECG has a broader role for left-sided valvular dysfunction.
“Vaid et al. applied deep learning to more than 600,000 ECG-echocardiogram pairs across five hospitals and externally validated models for both mitral regurgitation and aortic stenosis, supporting the broader role of AI-ECG for left-sided valvular dysfunction [31].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [31] Vaid, 2023, Multi-Center Retrospective Cohort Study Applying Deep Learning to Electrocardiograms to Identify Left Heart Valvular Dysfunction, Commun. Med. source
- Interpretationcitation
AI-ECG may identify a broader latent cardiac phenotype rather than merely detect current low ejection fraction.
“This suggests that AI-ECG may identify a broader latent cardiac phenotype rather than merely detect current low ejection fraction.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [22] Naser, 2024, Artificial Intelligence–Enhanced Electrocardiography Identifies Patients with Normal Ejection Fraction at Risk of Worse Outcomes, JACC Adv. source
- Premisecitation
AI-ECG has been used to predict HFpEF-related risk.
“More recent studies have extended this concept by using AI-ECG to predict left ventricular diastolic dysfunction and increased filling pressures [25] and HFpEF-related risk [26].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [26] Hong, 2025, Artificial Intelligence-Enabled Electrocardiogram Model for Predicting Heart Failure with Preserved Ejection Fraction: A Single-Center Study, Eur. Heart J.-Digit. Health source
- Premisecitation
The AI-ECG model for cardiac amyloidosis had lower performance in some subgroups, including Hispanic patients and patients with left ventricular hypertrophy or left bundle branch block.
“A subsequent post-development validation study found that the AI-ECG model retained good overall discrimination, with an AUC of 0.84, although performance was lower in some subgroups, including Hispanic patients and patients with left ventricular hypertrophy or left bundle branch block [34].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [34] Harmon, 2023, Postdevelopment Performance and Validation of the Artificial Intelligence-Enhanced Electrocardiogram for Detection of Cardiac Amyloidosis, JACC Adv. source
- Interpretationcitation
ECG waveforms could support noninvasive screening for a metabolic abnormality ordinarily diagnosed through laboratory testing.
“This study expanded AI-ECG by suggesting that ECG waveforms could support noninvasive screening for a metabolic abnormality ordinarily diagnosed through laboratory testing.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [6] Galloway, 2019, Development and Validation of a Deep-Learning Model to Screen for Hyperkalemia From the Electrocardiogram, JAMA Cardiol. source
- Rests on an assumption: Conventional ECG changes in hyperkalemia can be inconsistent and may be absent even when serum potassium is dangerously elevated.
- Interpretationreasoning
AI-ECG may help enrich the population selected for further evaluation with echocardiography, cardiac magnetic resonance imaging, nuclear scintigraphy, or serum and urine testing when clinical suspicion is present.
“AI-ECG may therefore help enrich the population selected for further evaluation with echocardiography, cardiac magnetic resonance imaging, nuclear scintigraphy, or serum and urine testing when clinical suspicion is present.”
Quote in the paperSubstantial claim2 of 3 sources checked- cites [32] Grogan, 2021, Artificial Intelligence–Enhanced Electrocardiogram for the Early Detection of Cardiac Amyloidosis, Mayo Clin. Proc. source
- cites [33] Goto, 2021, Artificial Intelligence-Enabled Fully Automated Detection of Cardiac Amyloidosis Using Electrocardiograms and Echocardiograms, Nat. Commun. source
The Discussion (page unavailable) proposes AI-based detection followed by echocardiography and confirmatory testing with free-light-chain measurement and scintigraphy. The Methods (page unavailable) also identifies cardiac MRI as a diagnostic modality. The paper does not specify urine testing in this pathway, and its proposed approach deliberately limits the need for prior clinical suspicion rather than making suspicion a condition for selection. (LLM, conf=0.84)
Experimental — accuracy not yet measured - cites [34] Harmon, 2023, Postdevelopment Performance and Validation of the Artificial Intelligence-Enhanced Electrocardiogram for Detection of Cardiac Amyloidosis, JACC Adv. source
The Discussion (‘AI-ECG performance and ECG features’; page unavailable) says the screening tool could elevate clinical suspicion for cardiac amyloidosis, supporting its potential to guide further evaluation. The paper does not specify using AI-ECG to select patients for the full list of follow-up tests in the claim, particularly cardiac MRI and serum or urine testing. (LLM, conf=0.84)
Experimental — accuracy not yet measured
- Rests on an assumption: Cardiac amyloidosis diagnosis is often delayed.
- Premisecitation
A deep learning algorithm detected aortic stenosis from ECGs.
“Kwon et al. developed a deep learning algorithm to detect aortic stenosis from ECGs, demonstrating that valvular disease may produce electrical signatures detectable beyond standard ECG criteria [29].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [29] Kwon, 2020, Deep Learning–Based Algorithm for Detecting Aortic Stenosis Using Electrocardiography, J. Am. Heart Assoc. source
- Premisecitation
AI-ECG can detect severe dyscalcemia.
“Reports of AI-ECG detection of severe dyscalcemia [16] further suggest that deep learning may recognize cardiovascular effects of systemic disease.”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [16] Lin, 2022, Artificial Intelligence-Enabled Electrocardiography Identifies Severe Dyscalcemias and Has Prognostic Value, Clin. Chim. Acta source
- Premisecitation
Patients with abnormal AI-ECG results despite normal contemporaneous systolic function were more likely to have other structural abnormalities or worse outcomes compared with true-negative patients.
“In outcome-focused analyses, patients with abnormal AI-ECG results despite normal contemporaneous systolic function were more likely to have other structural abnormalities or worse outcomes compared with true-negative patients [22].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [22] Naser, 2024, Artificial Intelligence–Enhanced Electrocardiography Identifies Patients with Normal Ejection Fraction at Risk of Worse Outcomes, JACC Adv. source
- Interpretationcitation
Deep learning may recognize cardiovascular effects of systemic disease.
“Reports of AI-ECG detection of severe dyscalcemia [16] further suggest that deep learning may recognize cardiovascular effects of systemic disease.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [16] Lin, 2022, Artificial Intelligence-Enabled Electrocardiography Identifies Severe Dyscalcemias and Has Prognostic Value, Clin. Chim. Acta source
- Premisecitation
A deep-learning model using only leads I and II detected hyperkalemia with AUC values ranging from 0.853 to 0.883 across validation sites in patients with renal disease.
“The model was trained on more than 1.5 million ECGs from over 449,000 patients and, using only leads I and II, detected hyperkalemia with AUC values ranging from 0.853 to 0.883 across validation sites [6].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [6] Galloway, 2019, Development and Validation of a Deep-Learning Model to Screen for Hyperkalemia From the Electrocardiogram, JAMA Cardiol. source
- Rests on an assumption: Conventional ECG changes in hyperkalemia can be inconsistent and may be absent even when serum potassium is dangerously elevated.
- Premisecitation
A deep learning model for early detection of HFpEF using ECG data had internal and external validation AUCs of 0.866 and 0.869.
“Kwon et al. developed a deep learning model for early detection of HFpEF using ECG data and reported promising discrimination in internal and external validation AUCs of 0.866 and 0.869, respectively [24].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [24] Kwon, 2021, Artificial Intelligence Assessment for Early Detection of Heart Failure with Preserved Ejection Fraction Based on Electrocardiographic Features, Eur. Heart J.-Digit. Health source
- Premisecitation
The AI-ECG algorithm's performance was lower in certain subgroups, including patients with tachycardia, atrial fibrillation, or wide QRS complexes.
“König et al. externally validated an existing AI-ECG algorithm in a European cohort and found good overall discrimination for left ventricular systolic dysfunction, although performance was lower in certain subgroups, including patients with tachycardia, atrial fibrillation, or wide QRS complexes [21].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [21] Hohenstein, 2024, Artificial Intelligence-Based Identification of Left Ventricular Systolic Dysfunction from 12-Lead Electrocardiograms: External Validation and Advanced Application of an Existing Model, Eur. Heart J.-Digit. Health source
- Premisecitation
AI-ECG has strong performance for detecting preclinical left ventricular systolic dysfunction in a community-based cohort.
“Kashou et al. studied a community-based cohort and reported strong performance for detecting preclinical left ventricular systolic dysfunction, supporting the potential role of AI-ECG in upstream screening before overt heart failure is recognized [17].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [17] Kashou, 2021, Artificial Intelligence-Augmented Electrocardiogram Detection of Left Ventricular Systolic Dysfunction in the General Population, Mayo Clin. Proc. source
- Premisecitation
A CNN using standard 12-lead ECGs detected HCM with an AUC of 0.96, sensitivity of 87%, and specificity of 90%.
“In a landmark study, Ko et al. developed a convolutional neural network using standard 12-lead ECGs to detect HCM and reported strong diagnostic performance, with an AUC of 0.96, sensitivity of 87%, and specificity of 90% [10].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [10] Ko, 2020, Detection of Hypertrophic Cardiomyopathy Using a Convolutional Neural Network-Enabled Electrocardiogram, J. Am. Coll. Cardiol. source
- Rests on an assumption: HCM may be underdiagnosed, particularly in patients with subtle or nonspecific ECG findings.
- Interpretationcitation
Valvular disease may produce electrical signatures detectable beyond standard ECG criteria.
“Kwon et al. developed a deep learning algorithm to detect aortic stenosis from ECGs, demonstrating that valvular disease may produce electrical signatures detectable beyond standard ECG criteria [29].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [29] Kwon, 2020, Deep Learning–Based Algorithm for Detecting Aortic Stenosis Using Electrocardiography, J. Am. Heart Assoc. source
- Premisecitation
A deep learning ECG model detected elevated estimated pulmonary artery pressure with an AUC of approximately 0.88, sensitivity of about 81%, and specificity of about 80%.
“Using paired ECG and echocardiographic data from more than 41,000 patients, the model identified elevated estimated pulmonary artery pressure with an AUC of approximately 0.88, along with sensitivity and specificity of about 81% and 80%, respectively.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [36] Liu, 2022, Artificial Intelligence-Enabled Electrocardiogram Improves the Diagnosis and Prediction of Mortality in Patients with Pulmonary Hypertension, JACC Asia source
- Premisecitation
A fully automated approach using ECGs and echocardiograms detected cardiac amyloidosis with strong internal and external performance.
“Goto et al. subsequently demonstrated a fully automated approach using ECGs and echocardiograms to detect cardiac amyloidosis, with strong internal and external performance [33].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [33] Goto, 2021, Artificial Intelligence-Enabled Fully Automated Detection of Cardiac Amyloidosis Using Electrocardiograms and Echocardiograms, Nat. Commun. source
- Premisecitation
PH-EDA achieved strong discrimination at the time of PH diagnosis.
“PH-EDA achieved strong discrimination at the time of PH diagnosis and also demonstrated predictive ability when applied to ECGs obtained months to years before clinical diagnosis.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [37] DuBrock, 2024, An Electrocardiogram-Based AI Algorithm for Early Detection of Pulmonary Hypertension, Eur. Respir. J. source
- Premisecitation
AI-ECG for HCM detection had an AUC of 0.922 across cohorts from Bern, Oxford, and Seoul.
“Subsequent international external validation further supported the transportability of AI-ECG for HCM detection, with Siontis et al. reporting an AUC of 0.922 across cohorts from Bern, Oxford, and Seoul [27].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [27] Siontis, 2024, Hypertrophic Cardiomyopathy Detection with Artificial Intelligence Electrocardiography in International Cohorts: An External Validation Study, Eur. Heart J.-Digit. Health source
- Premisecitation
AI-ECG has been used to predict left ventricular diastolic dysfunction and increased filling pressures.
“More recent studies have extended this concept by using AI-ECG to predict left ventricular diastolic dysfunction and increased filling pressures [25] and HFpEF-related risk [26].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [25] Lee, 2024, Artificial Intelligence-Enabled ECG for Left Ventricular Diastolic Function and Filling Pressure, npj Digit. Med. source
- Premisecitation
An AI-ECG model for cardiac amyloidosis retained good overall discrimination with an AUC of 0.84.
“A subsequent post-development validation study found that the AI-ECG model retained good overall discrimination, with an AUC of 0.84, although performance was lower in some subgroups, including Hispanic patients and patients with left ventricular hypertrophy or left bundle branch block [34].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [34] Harmon, 2023, Postdevelopment Performance and Validation of the Artificial Intelligence-Enhanced Electrocardiogram for Detection of Cardiac Amyloidosis, JACC Adv. source
- Premisecitation
PH-EDA demonstrated predictive ability when applied to ECGs obtained months to years before clinical diagnosis.
“PH-EDA achieved strong discrimination at the time of PH diagnosis and also demonstrated predictive ability when applied to ECGs obtained months to years before clinical diagnosis.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [37] DuBrock, 2024, An Electrocardiogram-Based AI Algorithm for Early Detection of Pulmonary Hypertension, Eur. Respir. J. source
- Premisecitation
AI-ECG prediction of future AF could enrich for patients at risk of AF-related stroke.
“Raghunath et al. showed that AI-ECG prediction of future AF could also enrich for patients at risk of AF-related stroke, supporting the potential use of these models for targeted screening and rhythm monitoring [13].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [13] Raghunath, 2021, Deep Neural Networks Can Predict New-Onset Atrial Fibrillation From the 12-Lead ECG and Help Identify Those at Risk of Atrial Fibrillation–Related Stroke, Circulation source
- Interpretationcitation
Earlier identification of PH may allow more timely echocardiography, specialist referral, and confirmatory hemodynamic testing when appropriate.
“This finding is clinically important because delayed recognition of PH is common, and earlier identification may allow more timely echocardiography, specialist referral, and confirmatory hemodynamic testing when appropriate [37].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [37] DuBrock, 2024, An Electrocardiogram-Based AI Algorithm for Early Detection of Pulmonary Hypertension, Eur. Respir. J. source
The Discussion (page unavailable) says earlier suspicion of PH could prompt echocardiography and further diagnostic evaluation, potentially accelerating diagnosis. The Introduction (page unavailable) identifies right-heart catheterisation as the definitive diagnostic test. The paper does not specifically discuss specialist referral, so that part of the attributed pathway is unsupported. (LLM, conf=0.84)
Experimental — accuracy not yet measured
- Rests on an assumption: Delayed recognition of pulmonary hypertension is common.
- Premisecitation
Deep learning applied to more than 600,000 ECG-echocardiogram pairs across five hospitals externally validated models for both mitral regurgitation and aortic stenosis.
“Vaid et al. applied deep learning to more than 600,000 ECG-echocardiogram pairs across five hospitals and externally validated models for both mitral regurgitation and aortic stenosis, supporting the broader role of AI-ECG for left-sided valvular dysfunction [31].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [31] Vaid, 2023, Multi-Center Retrospective Cohort Study Applying Deep Learning to Electrocardiograms to Identify Left Heart Valvular Dysfunction, Commun. Med. source
- Premisecitation
AI-ECG has been applied to 12-lead detection of both hypokalemia and hyperkalemia.
“Later work carried the approach to 12-lead detection of both hypokalemia and hyperkalemia [11] and point-of-care potassium estimation [15].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [11] Lin, 2020, A Deep-Learning Algorithm (ECG12Net) for Detecting Hypokalemia and Hyperkalemia by Electrocardiography: Algorithm Development, JMIR Med. Inform. source
- Premisecitation
AI-ECG sepsis screening reported AUCs of 0.901 internally and 0.863 externally using 12-lead ECGs.
“for sepsis screening, with reported AUCs of 0.901 internally and 0.863 externally using 12-lead ECGs [41].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [41] Kwon, 2021, Deep-Learning Model for Screening Sepsis Using Electrocardiography, Scand. J. Trauma Resusc. Emerg. Med. source
- Premisecitation
The association between AI-estimated ECG age and mortality persisted among individuals with apparently normal ECGs.
“This association persisted even among individuals with apparently normal ECGs”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [7] Lima, 2021, Deep Neural Network-Estimated Electrocardiographic Age as a Mortality Predictor, Nat. Commun. source
- Premisecitation
AI-ECG detection of hyperthyroidism was associated with increased risk of mortality and new-onset heart failure.
“A later study also found that AI-ECG detection of hyperthyroidism was associated with increased risk of mortality and new-onset heart failure [39].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [39] Lin, 2024, Artificial Intelligence-Enabled Electrocardiography Contributes to Hyperthyroidism Detection and Outcome Prediction, Commun. Med. source
- Interpretationcitation
The economic value of AI-ECG will depend less on the marginal cost of running the algorithm than on whether it improves the targeting of confirmatory testing and patient outcomes.
“Its economic value will depend less on the marginal cost of running the algorithm than on whether it improves the targeting of confirmatory testing and patient outcomes [43].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [43] Hsieh, 2025, Economic Analysis of an AI-Enabled ECG Alert System: Impact on Mortality Outcomes from a Pragmatic Randomized Trial, npj Digit. Med. source
The Discussion says the algorithm’s cost had little effect on cost-effectiveness and focuses instead on the costs of subsequent interventions relative to reduced mortality. It mentions echocardiograms to confirm low ejection fraction in a previous trial, but does not show that the alert system studied here improved the targeting of confirmatory testing. Page numbers are unavailable in our copy. (LLM, conf=0.84)
Experimental — accuracy not yet measured
- Premisecitation
Lee et al. compressed an ECG arrhythmia-classification model from 743 MB to 76 KB, an approximately 10,000-fold reduction, for embedded wearable deployment.
“Lee et al. compressed an ECG arrhythmia-classification model from 743 MB to 76 KB, an approximately 10,000-fold reduction, for embedded wearable deployment”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [66] Lee, K.-S., Park, H.-J., Kim, J.E., Kim, H.J., Chon, S., Kim, S., Jang, J., Kim, J.-K., Jang, S., and Gil, Y. (2022). Compressed Deep Learning to Classify Arrhythmia in an Embedded Wearable Device. Sensors, 22. source
- Premisecitation
Model-compression techniques such as quantization, pruning, and knowledge distillation can reduce model size and computational requirements, potentially enabling faster and more energy-efficient inference on low-power edge devices.
“Model-compression techniques such as quantization, pruning, and knowledge distillation can reduce model size and computational requirements, potentially enabling faster and more energy-efficient inference on low-power edge devices [65].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [65] Shumba, A.-T., Montanaro, T., Sergi, I., Bramanti, A., Ciccarelli, M., Rispoli, A., Carrizzo, A., De Vittorio, M., and Patrono, L. (2023). Wearable Technologies and AI at the Far Edge for Chronic Heart Failure Prevention and Management: A Systematic Review and Prospects. Sensors, 23. source
- Premisecitation
EchoNext broadened AI-ECG to structural abnormalities, with echocardiography as the confirmatory pathway.
“EchoNext broadened the same idea to structural abnormalities, again with echocardiography as the confirmatory pathway [42]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [42] Poterucha, 2025, Detecting Structural Heart Disease from Electrocardiograms Using AI, Nature source
- Premisecitation
Patients with discordance between laboratory and AI-predicted ECG potassium had worse outcomes.
“Patients with discordance between laboratory and AI-predicted ECG potassium also had worse outcomes, suggesting that AI-ECG potassium signals may reflect not only serum electrolyte concentration but also underlying physiologic vulnerability [15].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [15] Lin, 2022, Point-of-Care Artificial Intelligence-Enabled ECG for Dyskalemia: A Retrospective Cohort Analysis for Accuracy and Outcome Prediction, npj Digit. Med. source
- Interpretationcitation
Potassium models may prioritize urgent laboratory testing without replacing serum measurement.
“potassium models may prioritize urgent laboratory testing without replacing serum measurement [6,15].”
Quote in the paperNot a substantial claim2 of 2 sources checked- cites [6] Galloway, 2019, Development and Validation of a Deep-Learning Model to Screen for Hyperkalemia From the Electrocardiogram, JAMA Cardiol. source
The Discussion describes the ECG model as a noninvasive screen for hyperkalemia, and the Limitations discuss subsequent laboratory testing after a possible positive result. This supports using the model alongside, rather than in place of, serum testing. The paper does not specifically say that model results should prioritize urgent laboratory tests. (LLM, conf=0.82)
Experimental — accuracy not yet measured - cites [15] Lin, 2022, Point-of-Care Artificial Intelligence-Enabled ECG for Dyskalemia: A Retrospective Cohort Analysis for Accuracy and Outcome Prediction, npj Digit. Med. source
The Discussion (page unavailable) proposes using ECG-based potassium estimates to flag severe dyskalemia early and prepare interventions, but says to give those interventions upon receipt of a concordant laboratory result. This supports not replacing laboratory measurement; it does not specifically propose prioritizing urgent laboratory testing. (LLM, conf=0.83)
Experimental — accuracy not yet measured
- Premisecitation
The reduced-lead hyperkalemia model demonstrated that clinically relevant metabolic information can be retained using only two or four ECG leads.
“The reduced-lead hyperkalemia model discussed earlier demonstrated that clinically relevant metabolic information can be retained using only two or four ECG leads [6].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [6] Galloway, 2019, Development and Validation of a Deep-Learning Model to Screen for Hyperkalemia From the Electrocardiogram, JAMA Cardiol. source
- Interpretationcitation
AI-derived ECG age may capture latent cardiovascular health or physiologic reserve not apparent through standard interpretation.
“suggesting that AI-derived ECG age may capture latent cardiovascular health or physiologic reserve not apparent through standard interpretation [7].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [7] Lima, 2021, Deep Neural Network-Estimated Electrocardiographic Age as a Mortality Predictor, Nat. Commun. source
- Premisecitation
Deep learning models have been developed to detect overt hyperthyroidism from ECGs, with one multicenter study reporting AUCs of 0.926 for internal validation and 0.883 for external validation using 12-lead ECGs.
“Deep learning models have been developed to detect overt hyperthyroidism from ECGs, with one multicenter study reporting AUCs of 0.926 for internal validation and 0.883 for external validation using 12-lead ECGs [38].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [38] Choi, 2022, Electrocardiographic Biomarker Based on Machine Learning for Detecting Overt Hyperthyroidism, Eur. Heart J.-Digit. Health source
- Interpretationcitation
AI-ECG potassium signals may reflect not only serum electrolyte concentration but also underlying physiologic vulnerability.
“Patients with discordance between laboratory and AI-predicted ECG potassium also had worse outcomes, suggesting that AI-ECG potassium signals may reflect not only serum electrolyte concentration but also underlying physiologic vulnerability [15].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [15] Lin, 2022, Point-of-Care Artificial Intelligence-Enabled ECG for Dyskalemia: A Retrospective Cohort Analysis for Accuracy and Outcome Prediction, npj Digit. Med. source
- Premisecitation
A deep-learning model applied to single-lead ECGs obtained during ECG-enabled stethoscope examination could identify patients with a left ventricular ejection fraction of 40% or lower in a prospective multicenter study.
“Separately, a prospective multicenter study showed that a deep-learning model applied to single-lead ECGs obtained during examination with an ECG-enabled stethoscope could identify patients with a left ventricular ejection fraction of 40% or lower [64].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [64] Bachtiger, 2022, Point-of-Care Screening for Heart Failure with Reduced Ejection Fraction Using Artificial Intelligence during ECG-Enabled Stethoscope Examination in London, UK: A Prospective, Observational, Multicentre Study, Lancet Digit. Health source
- Premisecitation
Lima et al. trained a deep neural network to estimate age from 12-lead ECGs in the CODE study cohort, which included more than 1.5 million patients.
“Lima et al. trained a deep neural network to estimate age from 12-lead ECGs in the CODE study cohort, which included more than 1.5 million patients.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [7] Lima, 2021, Deep Neural Network-Estimated Electrocardiographic Age as a Mortality Predictor, Nat. Commun. source
- Premisecitation
A deep learning model detects moderate-to-severe anemia with AUCs of 0.854 internally and 0.824 externally.
“AI-ECG has also been studied for noninvasive hemoglobin estimation, with a deep learning model detecting moderate-to-severe anemia with AUCs of 0.854 internally and 0.824 externally [40]”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [40] Yang, 2026, Non-Invasive Hemoglobin Estimation with Outcome Prediction via Deep Learning Analysis of ECG-Derived Cardiac Micro-Dynamics, Intern. Emerg. Med. source
- Premisecitation
ECG waveforms contain latent signatures of future mortality risk.
“Emerging evidence suggests that ECG waveforms contain latent signatures of ventricular dysfunction [4], structural heart disease [5], metabolic abnormalities [6], and broader physiologic characteristics such as biological age [7] and future mortality risk [8].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [8] Raghunath, 2020, Prediction of Mortality from 12-Lead Electrocardiogram Voltage Data Using a Deep Neural Network, Nat. Med. source
- Premisecitation
ECG waveforms contain latent signatures of ventricular dysfunction.
“Emerging evidence suggests that ECG waveforms contain latent signatures of ventricular dysfunction [4], structural heart disease [5], metabolic abnormalities [6], and broader physiologic characteristics such as biological age [7] and future mortality risk [8].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [4] Attia, 2019, Screening for Cardiac Contractile Dysfunction Using an Artificial Intelligence–Enabled Electrocardiogram, Nat. Med. source
- Premisecitation
An AI-ECG model for pulmonary hypertension using standard 12-lead ECGs and clinical variables achieved AUC values of 0.859 and 0.902 in internal and external validation cohorts.
“The model was trained using more than 56,000 ECGs and demonstrated strong diagnostic performance for PH in both internal and external validation cohorts, with reported AUC values of 0.859 and 0.902, respectively.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [35] Kwon, 2020, Artificial Intelligence for Early Prediction of Pulmonary Hypertension Using Electrocardiography, J. Heart Lung Transplant. source
- Interpretationcitation
Patients with apparent false-positive AI-ECG results for aortic stenosis may still represent a higher-risk group, as some later developed clinically significant aortic stenosis.
“As with the ejection-fraction models, patients with apparent false-positive AI-ECG results here may still represent a higher-risk group, as some later developed clinically significant aortic stenosis [30].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [30] Attia, 2021, Electrocardiogram Screening for Aortic Valve Stenosis Using Artificial Intelligence, Eur. Heart J. source
- Interpretationcitation
AI-ECG can be positioned as a screening tool for both current and future ventricular dysfunction.
“Notably, patients with a positive AI-ECG despite a preserved ejection fraction were more likely to develop ventricular dysfunction during follow-up, suggesting that the model may be identifying subclinical disease rather than only established systolic dysfunction, positioning AI-ECG as a screening tool for both current and future ventricular dysfunction.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [4] Attia, 2019, Screening for Cardiac Contractile Dysfunction Using an Artificial Intelligence–Enabled Electrocardiogram, Nat. Med. source
- Interpretationcitation
Infiltrative myocardial disease produces subtle ECG features that can be recognized computationally.
“Grogan et al. developed an AI-ECG model for early detection of cardiac amyloidosis, supporting the concept that infiltrative myocardial disease produces subtle ECG features that can be recognized computationally [32].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [32] Grogan, 2021, Artificial Intelligence–Enhanced Electrocardiogram for the Early Detection of Cardiac Amyloidosis, Mayo Clin. Proc. source
- Premisecitation
An AI-ECG model was developed for early detection of cardiac amyloidosis.
“Grogan et al. developed an AI-ECG model for early detection of cardiac amyloidosis, supporting the concept that infiltrative myocardial disease produces subtle ECG features that can be recognized computationally [32].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [32] Grogan, 2021, Artificial Intelligence–Enhanced Electrocardiogram for the Early Detection of Cardiac Amyloidosis, Mayo Clin. Proc. source
- Rests on an assumption: Cardiac amyloidosis diagnosis is often delayed.
- Interpretationcitation
A routine ECG carries information about cardiac structure that a human reader cannot extract from the same tracing.
“The more striking implication was that a routine ECG carries information about cardiac structure that a human reader cannot extract from the same tracing.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [4] Attia, 2019, Screening for Cardiac Contractile Dysfunction Using an Artificial Intelligence–Enabled Electrocardiogram, Nat. Med. source
- Interpretationcitation
The EAGLE trial demonstrated that model output could alter real-world diagnostic behavior.
“Unlike most retrospective AI-ECG studies, the EAGLE trial demonstrated that model output could alter real-world diagnostic behavior.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [19] Yao, 2021, Artificial Intelligence–Enabled Electrocardiograms for Identification of Patients with Low Ejection Fraction: A Pragmatic, Randomized Clinical Trial, Nat. Med. source
- Premisecitation
An AI-enabled algorithm could identify AF-associated patterns from standard 12-lead ECGs recorded during sinus rhythm.
“However, Attia et al. demonstrated that an AI-enabled algorithm could identify AF-associated patterns from standard 12-lead ECGs recorded during sinus rhythm, suggesting that the ECG may contain latent signatures of atrial remodeling or electrophysiologic vulnerability even when AF is not present on the tracing itself [12].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [12] Attia, 2019, An Artificial Intelligence-Enabled ECG Algorithm for the Identification of Patients with Atrial Fibrillation during Sinus Rhythm: A Retrospective Analysis of Outcome Prediction, Lancet source
- Premisecitation
Patients with a positive AI-ECG despite a preserved ejection fraction were more likely to develop ventricular dysfunction during follow-up.
“Notably, patients with a positive AI-ECG despite a preserved ejection fraction were more likely to develop ventricular dysfunction during follow-up, suggesting that the model may be identifying subclinical disease rather than only established systolic dysfunction, positioning AI-ECG as a screening tool for both current and future ventricular dysfunction.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [4] Attia, 2019, Screening for Cardiac Contractile Dysfunction Using an Artificial Intelligence–Enabled Electrocardiogram, Nat. Med. source
- Interpretationcitation
AI systems may identify clinically relevant information that is not readily apparent through conventional interpretation or visual inspection by clinicians.
“As a result, AI systems may identify clinically relevant information that is not readily apparent through conventional interpretation or visual inspection by clinicians [4].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [4] Attia, 2019, Screening for Cardiac Contractile Dysfunction Using an Artificial Intelligence–Enabled Electrocardiogram, Nat. Med. source
- Interpretationreasoning
Because structural disorders are relatively uncommon in general populations, high discrimination does not necessarily translate into a high positive predictive value.
“Moreover, because these disorders are relatively uncommon in general populations, high discrimination does not necessarily translate into a high positive predictive value.”
Quote in the paperSubstantial claim- Rests on an assumption: Structural heart disorders are relatively uncommon in general populations.
- Premisecitation
Among patients without known PH at baseline, those classified as high risk by the AI model had a substantially higher subsequent incidence of PH than those classified as low risk.
“Importantly, among patients without known PH at baseline, those classified as high risk by the AI model had a substantially higher subsequent incidence of PH than those classified as low risk [35].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [35] Kwon, 2020, Artificial Intelligence for Early Prediction of Pulmonary Hypertension Using Electrocardiography, J. Heart Lung Transplant. source
- Interpretationcitation
AI-ECG may assist in triage settings where rapid identification of cardiac dysfunction can guide additional testing.
“Adedinsewo et al. evaluated an AI-enabled ECG algorithm in emergency department patients presenting with dyspnea, showing that AI-ECG may also assist in triage settings where rapid identification of cardiac dysfunction can guide additional testing [18].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [18] Adedinsewo, 2020, Artificial Intelligence-Enabled ECG Algorithm to Identify Patients With Left Ventricular Systolic Dysfunction Presenting to the Emergency Department with Dyspnea, Circ. Arrhythm. Electrophysiol. source
- Premisecitation
An AI-ECG algorithm for detecting left ventricular systolic dysfunction in Kenyan outpatient facilities had high sensitivity and negative predictive value compared with echocardiography.
“A recent study in Kenyan outpatient facilities evaluated an AI-ECG algorithm for detecting left ventricular systolic dysfunction and reported high sensitivity and negative predictive value compared with echocardiography [23].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [23] Pandey, 2026, Artificial Intelligence Electrocardiogram and Left Ventricular Systolic Dysfunction in Kenya, JAMA Cardiol. source
- Interpretationcitation
A highly sensitive AI-ECG could help prioritize limited imaging resources for patients most likely to benefit from confirmatory echocardiography.
“This type of performance is clinically relevant because a highly sensitive AI-ECG could help prioritize limited imaging resources for patients most likely to benefit from confirmatory echocardiography.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [23] Pandey, 2026, Artificial Intelligence Electrocardiogram and Left Ventricular Systolic Dysfunction in Kenya, JAMA Cardiol. source
- Interpretationcitation
AI-ECG may identify subclinical disease rather than only established systolic dysfunction.
“Notably, patients with a positive AI-ECG despite a preserved ejection fraction were more likely to develop ventricular dysfunction during follow-up, suggesting that the model may be identifying subclinical disease rather than only established systolic dysfunction, positioning AI-ECG as a screening tool for both current and future ventricular dysfunction.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [4] Attia, 2019, Screening for Cardiac Contractile Dysfunction Using an Artificial Intelligence–Enabled Electrocardiogram, Nat. Med. source
- Interpretationreasoning
AI-ECG is best viewed as a tool for selecting patients for confirmatory imaging rather than establishing a structural diagnosis independently.
“AI-ECG is therefore best viewed as a tool for selecting patients for confirmatory imaging rather than establishing a structural diagnosis independently.”
Quote in the paperSubstantial claim - Premisecitation
In the EAGLE trial, the intervention increased new diagnoses of low ejection fraction within 90 days, particularly among patients with a positive AI screen.
“The intervention increased new diagnoses of low ejection fraction within 90 days, particularly among patients with a positive AI screen, and increased targeted echocardiography in the AI-positive subgroup without substantially increasing echocardiography use across the entire population [19].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [19] Yao, 2021, Artificial Intelligence–Enabled Electrocardiograms for Identification of Patients with Low Ejection Fraction: A Pragmatic, Randomized Clinical Trial, Nat. Med. source
- Interpretationcitation
The ECG may contain latent signatures of atrial remodeling or electrophysiologic vulnerability even when AF is not present on the tracing.
“However, Attia et al. demonstrated that an AI-enabled algorithm could identify AF-associated patterns from standard 12-lead ECGs recorded during sinus rhythm, suggesting that the ECG may contain latent signatures of atrial remodeling or electrophysiologic vulnerability even when AF is not present on the tracing itself [12].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [12] Attia, 2019, An Artificial Intelligence-Enabled ECG Algorithm for the Identification of Patients with Atrial Fibrillation during Sinus Rhythm: A Retrospective Analysis of Outcome Prediction, Lancet source
- Interpretationreasoning
Evidence for valvular disease and cardiac amyloidosis remains more dependent on retrospective cohorts assembled from patients who underwent both ECG and imaging.
“Evidence for valvular disease and cardiac amyloidosis is also encouraging but remains more dependent on retrospective cohorts assembled from patients who underwent both ECG and imaging.”
Quote in the paperSubstantial claim - Study design and conductcitation
The EAGLE trial was a pragmatic cluster-randomized trial evaluating AI-guided screening for low ejection fraction in primary care.
“A major step toward clinical implementation came with the EAGLE trial, a pragmatic cluster-randomized trial evaluating AI-guided screening for low ejection fraction in primary care.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [19] Yao, 2021, Artificial Intelligence–Enabled Electrocardiograms for Identification of Patients with Low Ejection Fraction: A Pragmatic, Randomized Clinical Trial, Nat. Med. source
- Interpretationreasoning
AI-ECG could help select patients for ambulatory monitoring or closer rhythm surveillance.
“Because AF may remain intermittent and undetected until complications such as stroke occur, AI-ECG could help select patients for ambulatory monitoring or closer rhythm surveillance.”
Quote in the paperSubstantial claim- Rests on an assumption: AF may remain intermittent and undetected until complications such as stroke occur.
- Premisecitation
AI-ECG screening for moderate-to-severe aortic stenosis in a large Mayo Clinic cohort had a sensitivity of 78% and specificity of 74%.
“Cohen-Shelly et al. later evaluated AI-ECG screening for moderate-to-severe aortic stenosis in a large Mayo Clinic cohort and reported a sensitivity of 78% and specificity of 74%.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [30] Attia, 2021, Electrocardiogram Screening for Aortic Valve Stenosis Using Artificial Intelligence, Eur. Heart J. source
- Interpretationreasoning
Current evidence does not establish a universally superior deep learning architecture for AI-ECG analysis.
“Therefore, current evidence does not establish a universally superior deep learning architecture for AI-ECG analysis.”
Quote in the paperNot a substantial claim - Interpretationnone given
AI-ECG models can estimate mortality risk.
“AI-ECG models have demonstrated the ability to detect reduced left ventricular ejection fraction, hypertrophic cardiomyopathy, valvular disease, cardiac amyloidosis, pulmonary hypertension, hyperkalemia and other dyskalemias, hyperthyroidism, anemia, and sepsis, and to estimate biologic age and mortality risk.”
Quote in the paperSubstantial claim - Premisecitation
Raghunath et al. trained a deep neural network using more than 1.1 million 12-lead ECGs from over 250,000 patients to predict one-year all-cause mortality.
“Raghunath et al. trained a deep neural network using more than 1.1 million 12-lead ECGs from over 250,000 patients to predict one-year all-cause mortality.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [8] Raghunath, 2020, Prediction of Mortality from 12-Lead Electrocardiogram Voltage Data Using a Deep Neural Network, Nat. Med. source
- Interpretationnone given
AI-ECG models can detect anemia.
“AI-ECG models have demonstrated the ability to detect reduced left ventricular ejection fraction, hypertrophic cardiomyopathy, valvular disease, cardiac amyloidosis, pulmonary hypertension, hyperkalemia and other dyskalemias, hyperthyroidism, anemia, and sepsis, and to estimate biologic age and mortality risk.”
Quote in the paperSubstantial claim - Premisecitation
The mortality prediction model maintained strong performance among ECGs interpreted as normal by physicians, with an AUC of 0.85.
“maintained strong performance even among ECGs interpreted as normal by physicians, with an AUC of 0.85.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [8] Raghunath, 2020, Prediction of Mortality from 12-Lead Electrocardiogram Voltage Data Using a Deep Neural Network, Nat. Med. source
- Interpretationnone given
AI-ECG models can detect hyperthyroidism.
“AI-ECG models have demonstrated the ability to detect reduced left ventricular ejection fraction, hypertrophic cardiomyopathy, valvular disease, cardiac amyloidosis, pulmonary hypertension, hyperkalemia and other dyskalemias, hyperthyroidism, anemia, and sepsis, and to estimate biologic age and mortality risk.”
Quote in the paperSubstantial claim - Interpretationreasoning
AI-ECG models are highly dependent on the data used for training and validation.
“AI-ECG models are highly dependent on the data used for training and validation.”
Quote in the paperSubstantial claim - Interpretationnone given
AI-ECG models can estimate biologic age.
“AI-ECG models have demonstrated the ability to detect reduced left ventricular ejection fraction, hypertrophic cardiomyopathy, valvular disease, cardiac amyloidosis, pulmonary hypertension, hyperkalemia and other dyskalemias, hyperthyroidism, anemia, and sepsis, and to estimate biologic age and mortality risk.”
Quote in the paperSubstantial claim - Interpretationcitation
AI-ECG can extract prognostic information from ECG waveforms that may not be visually apparent.
“This study demonstrated that AI-ECG can extract prognostic information from ECG waveforms that may not be visually apparent”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [8] Raghunath, 2020, Prediction of Mortality from 12-Lead Electrocardiogram Voltage Data Using a Deep Neural Network, Nat. Med. source
- Interpretationcitation
AI-ECG may enable opportunistic screening by applying additional analysis to ECGs already obtained during outpatient visits, emergency evaluations, preoperative testing, and chronic disease follow-up.
“AI-ECG may enable opportunistic screening by applying additional analysis to ECGs already obtained during outpatient visits, emergency evaluations, preoperative testing, and chronic disease follow-up.”
Quote in the paperSubstantial claim - Interpretationown data
ECG-age and mortality models demonstrate strong prognostic associations.
“ECG-age and mortality models demonstrate strong prognostic associations”
Quote in the paperSubstantial claim - Interpretationreasoning
AI-ECG has the potential to scale because it adds computational analysis to a relatively inexpensive test already embedded in routine care.
“AI-ECG has the potential to scale because it adds computational analysis to a relatively inexpensive test already embedded in routine care.”
Quote in the paperSubstantial claim - Interpretationreasoning
Since PH is relatively uncommon in general ECG populations, positive predictive value may be limited when AI-ECG is applied broadly.
“Since PH is also relatively uncommon in general ECG populations, positive predictive value may be limited when AI-ECG is applied broadly.”
Quote in the paperSubstantial claim - Interpretationnone given
Dataset bias can occur when training populations differ from the patients in whom the model is later applied.
“Dataset bias can occur when training populations differ from the patients in whom the model is later applied.”
Quote in the paperSubstantial claim - Interpretationreasoning
Differences in patient populations, ECG acquisition systems, and disease prevalence across hospitals can complicate model convergence in federated learning.
“differences in patient populations, ECG acquisition systems, and disease prevalence across hospitals can complicate model convergence”
Quote in the paperNot a substantial claim - Interpretationreasoning
Evidence is strongest for dyskalemia because potassium-related models have been evaluated in large cohorts, across different clinical settings, and with laboratory measurements serving as an objective reference standard.
“The evidence is strongest for dyskalemia because potassium-related models have been evaluated in large cohorts, across different clinical settings, and with laboratory measurements serving as an objective reference standard.”
Quote in the paperSubstantial claim - Interpretationreasoning
The clinical value of AI-ECG is less certain for broad prognostic outputs when no standardized intervention follows a high-risk result.
“Its clinical value is less certain for broad prognostic outputs when no standardized intervention follows a high-risk result.”
Quote in the paperSubstantial claim - Premisecitation
ECG-specific studies have demonstrated the feasibility of federated training across heterogeneous datasets, including deep neural networks applied to raw 12-lead ECG signals.
“ECG-specific studies have demonstrated the feasibility of federated training across heterogeneous datasets, including deep neural networks applied to raw 12-lead ECG signals [68].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [68] Weimann, 2024, Federated Learning with Deep Neural Networks: A Privacy-Preserving Approach to Enhanced ECG Classification, IEEE J. Biomed. Health Inform. source
- Interpretationnone given
AI-ECG models can detect sepsis.
“AI-ECG models have demonstrated the ability to detect reduced left ventricular ejection fraction, hypertrophic cardiomyopathy, valvular disease, cardiac amyloidosis, pulmonary hypertension, hyperkalemia and other dyskalemias, hyperthyroidism, anemia, and sepsis, and to estimate biologic age and mortality risk.”
Quote in the paperSubstantial claim - Premisecitation
Cardiologists reviewing selected normal ECGs were unable to reliably identify the mortality-associated patterns detected by the model.
“Cardiologists reviewing selected normal ECGs were unable to reliably identify the mortality-associated patterns detected by the model [8].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [8] Raghunath, 2020, Prediction of Mortality from 12-Lead Electrocardiogram Voltage Data Using a Deep Neural Network, Nat. Med. source
- Interpretationreasoning
Across systemic applications, AI-ECG can extract diagnostic and prognostic information beyond the heart itself.
“Across these systemic applications, AI-ECG can clearly extract diagnostic and prognostic information beyond the heart itself.”
Quote in the paperSubstantial claim - Interpretationreasoning
The usefulness of AI-ECG screening depends heavily on disease prevalence, because even models with strong discrimination may have modest positive predictive value in low-prevalence populations.
“The usefulness of screening depends heavily on disease prevalence, because even models with strong discrimination may have modest positive predictive value in low-prevalence populations.”
Quote in the paperSubstantial claim- Rests on an assumption: Disease prevalence strongly influences positive predictive value.
- Premisecitation
The mortality prediction model achieved an AUC of 0.88 in the held-out test set.
“The model achieved an AUC of 0.88 in the held-out test set”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [8] Raghunath, 2020, Prediction of Mortality from 12-Lead Electrocardiogram Voltage Data Using a Deep Neural Network, Nat. Med. source
- Classified as probably not a substantial claim. 45
- May combine two claims. 38
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationDeep learning models can identify intricate patterns within large datasets without requiring explicit feature selection.
“Unlike traditional rule-based approaches, deep learning models can identify intricate patterns within large datasets without requiring explicit feature selection [3].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [3] Fahim, 2025, Artificial Intelligence in Healthcare and Medicine: Clinical Applications, Therapeutic Advances, and Future Perspectives, Eur. J. Med. Res. source
The Foundational AI technologies sections (Deep learning and Machine learning; pages unavailable) say that deep learning represents complex, high-dimensional data and enhances feature extraction, while machine learning recognizes patterns in extensive, intricate datasets. They do not establish that deep learning requires no explicit feature selection or make the claimed comparison with traditional rule-based approaches. (LLM, conf=0.78)
Experimental — accuracy not yet measured
May combine two claims.
PremisecitationThe model for elevated estimated pulmonary artery pressure performed consistently across important clinical subgroups and was externally validated in an independent cohort.
“The model also performed consistently across important clinical subgroups and was externally validated in an independent cohort [36].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [36] Liu, 2022, Artificial Intelligence-Enabled Electrocardiogram Improves the Diagnosis and Prediction of Mortality in Patients with Pulmonary Hypertension, JACC Asia source
May combine two claims.
PremisecitationDeep learning models analyze the entire ECG waveform and can detect subtle patterns distributed across multiple leads.
“Rather than focusing solely on established ECG features such as intervals, amplitudes, and segment morphology, deep learning models analyze the entire waveform and can detect subtle patterns distributed across multiple leads [9].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [9] Ribeiro, 2020, Automatic Diagnosis of the 12-Lead ECG Using a Deep Neural Network, Nat. Commun. source
The Discussion says the end-to-end classifier takes the raw ECG signal and learns features rather than relying on features extracted by traditional methods. Methods > Neural network architecture and training says the input contains the sampled signal from each lead. The paper does not establish that the detected patterns are subtle or distributed across multiple leads. (LLM, conf=0.85)
Experimental — accuracy not yet measured
May combine two claims.
InterpretationcitationHCM has shown consistently high discrimination, international external validation, and early real-world implementation, making it one of the more reproducible structural AI-ECG targets.
“HCM has shown consistently high discrimination, international external validation, and early real-world implementation, making it one of the more reproducible structural AI-ECG targets.”
Quote in the paperSubstantial claim3 of 3 sources checked- cites [10] Ko, 2020, Detection of Hypertrophic Cardiomyopathy Using a Convolutional Neural Network-Enabled Electrocardiogram, J. Am. Coll. Cardiol. source
The Discussion (page not provided) reports high discrimination across the training, validation, and testing cohorts, with AUCs of 0.97, 0.95, and 0.96. But the Conclusions and Study Limitations (pages not provided) say the model still requires external validation and describe screening as a future possibility; this paper does not support international external validation or real-world implementation. (LLM, conf=0.90)
Experimental — accuracy not yet measured - cites [27] Siontis, 2024, Hypertrophic Cardiomyopathy Detection with Artificial Intelligence Electrocardiography in International Cohorts: An External Validation Study, Eur. Heart J.-Digit. Health source
The Methods and results report high discrimination (AUC 0.922) across external cohorts in Switzerland, the UK, and South Korea; the Discussion also describes favourable performance across diverse cohorts. But the Conclusion says clinical implementation still needs prospective evaluation. An earlier internal validation in routine clinical practice is mentioned, not evidence that this algorithm had been implemented in real-world care. Page numbers are unavailable in our copy. (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [28] Desai, 2025, Real-World Artificial Intelligence-Based Electrocardiographic Analysis to Diagnose Hypertrophic Cardiomyopathy, JACC Clin. Electrophysiol. source
The Discussion reports an external-dataset AUC of 0.975, and the Conclusions describe real-world clinical implementation for HCM detection at one center. Our copy does not establish international external validation or compare HCM with other structural AI-ECG targets for reproducibility; the Discussion cautions that this single-center study may not generalize across geographic settings. (LLM, conf=0.86)
Experimental — accuracy not yet measured
- Rests on an assumption: HCM may be underdiagnosed, particularly in patients with subtle or nonspecific ECG findings.
May combine two claims.
InterpretationcitationAI-ECG has a dual role: opportunistic screening in asymptomatic patients and evaluation of symptomatic patients in whom ventricular dysfunction is part of the differential.
“Read together, these studies point to a dual role: opportunistic screening in asymptomatic patients, and evaluation of symptomatic patients in whom ventricular dysfunction is part of the differential.”
Quote in the paperSubstantial claim1 of 2 sources checked- cites [17] Kashou, 2021, Artificial Intelligence-Augmented Electrocardiogram Detection of Left Ventricular Systolic Dysfunction in the General Population, Mayo Clin. Proc. source
The Methods section models AI-ECG screening in a community population without heart-failure symptoms, and the Discussion describes its potential as a screening tool for preclinical LVSD. The paper does not establish the other proposed role—evaluating symptomatic patients when ventricular dysfunction is in the differential. Its Discussion mentions an earlier clinical ECG study, but does not identify that study’s patients as symptomatic or frame it around that diagnostic use. (LLM, conf=0.88)
Experimental — accuracy not yet measured - cites [18] Adedinsewo, 2020, Artificial Intelligence-Enabled ECG Algorithm to Identify Patients With Left Ventricular Systolic Dysfunction Presenting to the Emergency Department with Dyspnea, Circ. Arrhythm. Electrophysiol. source
May combine two claims.
PremisecitationAI-ECG-based HCM alerts can be deployed in routine care, although positive results still require clinical correlation and confirmatory imaging.
“More recent real-world implementation studies suggest that AI-ECG-based HCM alerts can be deployed in routine care, although positive results still require clinical correlation and confirmatory imaging [28].”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [28] Desai, 2025, Real-World Artificial Intelligence-Based Electrocardiographic Analysis to Diagnose Hypertrophic Cardiomyopathy, JACC Clin. Electrophysiol. source
May combine two claims.
InterpretationcitationRoutine ECGs may contain information reflecting pulmonary vascular load, right ventricular pressure overload, or secondary electrical changes caused by altered cardiopulmonary hemodynamics.
“These findings support the possibility that routine ECGs may contain information reflecting pulmonary vascular load, right ventricular pressure overload, or secondary electrical changes caused by altered cardiopulmonary hemodynamics.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [36] Liu, 2022, Artificial Intelligence-Enabled Electrocardiogram Improves the Diagnosis and Prediction of Mortality in Patients with Pulmonary Hypertension, JACC Asia source
The Results (page not provided) show that ECG leads V1–V3 helped the AI model predict elevated pulmonary artery pressure and that their signals were consistent with right ventricular hypertrophy. This supports the possibility that ECGs contain relevant information, but the paper does not establish that the signals reflect pulmonary vascular load or electrical changes caused by altered cardiopulmonary hemodynamics. (LLM, conf=0.78)
Experimental — accuracy not yet measured
May combine two claims.
InterpretationcitationThe pulmonary hypertension literature shows consistent discrimination across multiple cohorts and suggests that AI-ECG may identify disease before formal diagnosis.
“Overall, the pulmonary hypertension literature shows consistent discrimination across multiple cohorts and suggests that AI-ECG may identify disease before formal diagnosis.”
Quote in the paperSubstantial claim2 of 3 sources checked- cites [35] Kwon, 2020, Artificial Intelligence for Early Prediction of Pulmonary Hypertension Using Electrocardiography, J. Heart Lung Transplant. source
- cites [36] Liu, 2022, Artificial Intelligence-Enabled Electrocardiogram Improves the Diagnosis and Prediction of Mortality in Patients with Pulmonary Hypertension, JACC Asia source
- cites [37] DuBrock, 2024, An Electrocardiogram-Based AI Algorithm for Early Detection of Pulmonary Hypertension, Eur. Respir. J. source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe compressed ECG arrhythmia-classification model variants achieved accuracies of 97.2% to 98.2%.
“reporting accuracies of 97.2% to 98.2%”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [66] Lee, K.-S., Park, H.-J., Kim, J.E., Kim, H.J., Chon, S., Kim, S., Jang, J., Kim, J.-K., Jang, S., and Gil, Y. (2022). Compressed Deep Learning to Classify Arrhythmia in an Embedded Wearable Device. Sensors, 22. source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationRecent work evaluating attribution methods for ECG classification has emphasized the need for sanity checks, rigorous validation, and caution when using post-hoc explanations in high-stakes clinical settings.
“Recent work evaluating attribution methods for ECG classification has emphasized the need for sanity checks, rigorous validation, and caution when using post-hoc explanations in high-stakes clinical settings [50].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [50] Arends, 2026, Signal or Noise? Evaluating Commonly Used Attribution Methods for Explaining Deep Neural Networks in Electrocardiogram Classification, Eur. Heart J.-Digit. Health source
May combine two claims.
PremisecitationSurveys of cardiologists suggest generally favorable views regarding the potential of AI to improve efficiency and patient care, but adoption remains uneven because of concerns regarding model validation, transparency, unfamiliarity with AI methods, and trust in automated recommendations.
“Surveys of cardiologists suggest generally favorable views regarding the potential of AI to improve efficiency and patient care, but adoption remains uneven because of concerns regarding model validation, transparency, unfamiliarity with AI methods, and trust in automated recommendations [45].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [45] Schepart, 2023, Artificial Intelligence-Enabled Tools in Cardiovascular Medicine: A Survey of Current Use, Perceptions, and Challenges, Cardiovasc. Digit. Health J. source
May combine two claims.
PremisecitationPatients whose AI-estimated ECG age was more than eight years older than their chronological age had significantly higher mortality, while those whose ECG age was more than eight years younger had lower mortality.
“Patients whose AI-estimated ECG age was more than eight years older than their chronological age had significantly higher mortality, while those whose ECG age was more than eight years younger had lower mortality.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [7] Lima, 2021, Deep Neural Network-Estimated Electrocardiographic Age as a Mortality Predictor, Nat. Commun. source
May combine two claims.
PremisecitationA point-of-care AI-enabled ECG model estimated serum potassium and detected both hypokalemia and hyperkalemia in emergency department patients.
“Lin et al. developed a point-of-care AI-enabled ECG model to estimate serum potassium and detect both hypokalemia and hyperkalemia in emergency department patients.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [15] Lin, 2022, Point-of-Care Artificial Intelligence-Enabled ECG for Dyskalemia: A Retrospective Cohort Analysis for Accuracy and Outcome Prediction, npj Digit. Med. source
Classified as probably not a substantial claim.
InterpretationcitationECG-age, mortality-prediction, and disease-specific models illustrate how AI-derived outputs may function as quantitative markers of physiologic risk rather than simple diagnostic labels.
“As discussed above, ECG-age [7], mortality-prediction [8], and disease-specific models illustrate how AI-derived outputs may function as quantitative markers of physiologic risk rather than simple diagnostic labels.”
Quote in the paperSubstantial claim1 of 2 sources checkedMay combine two claims.
PremisecitationIn a cohort including more than 34,000 emergency department visits with paired ECG and laboratory potassium measurements, the model achieved AUC values greater than 0.95 for moderate-to-severe hyperkalemia and greater than 0.85 for moderate-to-severe hypokalemia.
“In a cohort including more than 34,000 emergency department visits with paired ECG and laboratory potassium measurements, the model achieved AUC values greater than 0.95 for moderate-to-severe hyperkalemia and greater than 0.85 for moderate-to-severe hypokalemia.”
Quote in the paperSubstantial claim1 of 1 sources checked- cites [15] Lin, 2022, Point-of-Care Artificial Intelligence-Enabled ECG for Dyskalemia: A Retrospective Cohort Analysis for Accuracy and Outcome Prediction, npj Digit. Med. source
Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measured
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationDigital-biomarker frameworks emphasize analytical validity, clinical validity, reproducibility, and usefulness within a clearly defined clinical context.
“More broadly, digital-biomarker frameworks emphasize analytical validity, clinical validity, reproducibility, and usefulness within a clearly defined clinical context [69].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [69] Lieberwirth, 2026, Challenges and Potential of Using Digital Biomarkers in Healthcare and Clinical Trials, Commun. Med. source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe compressed ECG arrhythmia-classification model variants had inference times of approximately 150 to 600 ms.
“inference times of approximately 150 to 600 ms across the model variants evaluated”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [66] Lee, K.-S., Park, H.-J., Kim, J.E., Kim, H.J., Chon, S., Kim, S., Jang, J., Kim, J.-K., Jang, S., and Gil, Y. (2022). Compressed Deep Learning to Classify Arrhythmia in an Embedded Wearable Device. Sensors, 22. source
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
PremisecitationOther work has used broader explainability frameworks to compare model attention with known cardiologist decision rules and to investigate whether deep learning models use clinically plausible ECG features.
“Other work has used broader explainability frameworks to compare model attention with known cardiologist decision rules and to investigate whether deep learning models use clinically plausible ECG features [49].”
Quote in the paperNot a substantial claim1 of 1 sources checked- cites [49] Wagner, 2024, Explaining Deep Learning for ECG Analysis: Building Blocks for Auditing and Knowledge Discovery, Comput. Biol. Med. source
May combine two claims.
PremisecitationConventional ECG interpretation relies on predefined waveform characteristics and rule-based pattern recognition, which may miss subtler physiologic and pathologic signals.
“Conventional interpretation relies on predefined waveform characteristics and rule-based pattern recognition, which may miss subtler physiologic and pathologic signals [2].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [2] Kligfield, 2007, Recommendations for the Standardization and Interpretation of the Electrocardiogram: Part I: The Electrocardiogram and Its Technology: A Scientific Statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society: Endorsed by the International Society for Computerized Electrocardiology, Circulation source
May combine two claims.
InterpretationreasoningSuch cohorts may introduce verification and referral bias and may not reflect performance in unselected screening populations.
“Such cohorts may introduce verification and referral bias and may not reflect performance in unselected screening populations.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningAI-ECG performance varies across populations and may be affected by rhythm, conduction abnormalities, disease prevalence, and the threshold selected for a positive result.
“Nevertheless, performance varies across populations and may be affected by rhythm, conduction abnormalities, disease prevalence, and the threshold selected for a positive result.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationcitationAI-ECG may not only identify existing pulmonary hypertension but may also detect early ECG signatures associated with future disease development.
“This suggested that AI-ECG may not only identify existing pulmonary hypertension but may also detect early ECG signatures associated with future disease development.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [35] Kwon, 2020, Artificial Intelligence for Early Prediction of Pulmonary Hypertension Using Electrocardiography, J. Heart Lung Transplant. source
May combine two claims.
InterpretationreasoningEvidence for HFpEF and diastolic dysfunction remains less mature, with greater heterogeneity in disease definitions and limited prospective evidence that AI-guided detection improves clinical outcomes.
“Evidence for HFpEF and diastolic dysfunction remains less mature, with greater heterogeneity in disease definitions and limited prospective evidence that AI-guided detection improves clinical outcomes.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningReduced-ejection-fraction detection is the most clinically mature AI-ECG application and the closest to routine use.
“Of the applications reviewed here, reduced-ejection-fraction detection is the most clinically mature and the closest to routine use: the evidence spans large derivation cohorts, external validation, prognostic follow-up, and a pragmatic implementation trial.”
Quote in the paperSubstantial claimMay combine two claims.
PremisecitationIn the EAGLE trial, the intervention increased targeted echocardiography in the AI-positive subgroup without substantially increasing echocardiography use across the entire population.
“The intervention increased new diagnoses of low ejection fraction within 90 days, particularly among patients with a positive AI screen, and increased targeted echocardiography in the AI-positive subgroup without substantially increasing echocardiography use across the entire population [19].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [19] Yao, 2021, Artificial Intelligence–Enabled Electrocardiograms for Identification of Patients with Low Ejection Fraction: A Pragmatic, Randomized Clinical Trial, Nat. Med. source
May combine two claims.
PremisecitationAttia et al.'s CNN identified patients with LVEF ≤ 35% with an AUC of 0.93, sensitivity of 86.3%, and specificity of 85.7%.
“The model achieved an area under the receiver operating characteristic curve (AUC) of 0.93, with a sensitivity of 86.3% and specificity of 85.7%, a strong performance for a test this cheap and widely available [4].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [4] Attia, 2019, Screening for Cardiac Contractile Dysfunction Using an Artificial Intelligence–Enabled Electrocardiogram, Nat. Med. source
Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Interpretationnone givenVariations in the interval between ECG acquisition and blood sampling, treatment administered before testing, renal function, and medication use may affect the relationship between the ECG signal and measured electrolyte concentration.
“variations in the interval between ECG acquisition and blood sampling, treatment administered before testing, renal function, and medication use may affect the relationship between the ECG signal and measured electrolyte concentration.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationcitationCost-effectiveness of AI-ECG depends on disease prevalence, alert thresholds, implementation costs, and downstream testing.
“cost-effectiveness depends on disease prevalence, alert thresholds, implementation costs, and downstream testing.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing), S4 (based).
InterpretationreasoningAlert fatigue is a related and underappreciated risk.
“Alert fatigue is a related and underappreciated risk.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningInterpretability creates practical challenges for clinical adoption, since physicians may be hesitant to act on a prediction if they cannot determine whether the model is relying on physiologically meaningful ECG features or on spurious correlations, artifacts, or dataset-specific patterns.
“This creates practical challenges for clinical adoption, since physicians may be hesitant to act on a prediction if they cannot determine whether the model is relying on physiologically meaningful ECG features or on spurious correlations, artifacts, or dataset-specific patterns.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe FDA qualifies biomarkers for a specific context of use, particularly within medical-product and drug-development programs.
“In regulatory settings, the FDA similarly qualifies biomarkers for a specific context of use, particularly within medical-product and drug-development programs [70].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [70] U.S. Food and Drug Administration (2026, July 17). About Biomarkers and Qualification, Available online: https://www.fda.gov/drugs/biomarker-qualification-program/about-biomarkers-and-qualification.
Not checked in the free run.
May combine two claims.
PremisecitationThe EAGLE trial delivered AI results through the electronic health record while clinicians retained responsibility for ordering confirmatory echocardiography.
“The EAGLE trial, discussed above, provides an early example of this model: AI results were delivered through the electronic health record (EHR) while clinicians retained responsibility for ordering confirmatory echocardiography [19].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [19] Yao, 2021, Artificial Intelligence–Enabled Electrocardiograms for Identification of Patients with Low Ejection Fraction: A Pragmatic, Randomized Clinical Trial, Nat. Med. source
May combine two claims.
Interpretationnone givenScalability of AI-ECG is not automatic and depends on digital waveform storage, compatible ECG systems, software integration, technical support, and an available pathway for responding to positive results.
“scalability is not automatic and depends on digital waveform storage, compatible ECG systems, software integration, technical support, and an available pathway for responding to positive results.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningA highlighted waveform segment does not necessarily prove that the model is using a clinically valid feature, and different explainability methods may produce different results for the same ECG.
“A highlighted waveform segment does not necessarily prove that the model is using a clinically valid feature, and different explainability methods may produce different results for the same ECG.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim.
InterpretationreasoningFalse positives from AI-ECG screening may lead to additional testing, patient anxiety, and increased resource use.
“False positives may lead to additional testing, patient anxiety, and increased resource use”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S2 (checkable).
InterpretationcitationPhysician oversight remains essential because symptoms, comorbidities, ECG quality, rhythm, and conduction abnormalities may affect the meaning of a model output.
“Physician oversight remains essential because symptoms, comorbidities, ECG quality, rhythm, and conduction abnormalities may affect the meaning of a model output.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Interpretationnone givenMany AI-ECG studies in pulmonary hypertension use echocardiographic estimates of pulmonary artery pressure as the reference standard, even though right heart catheterization remains the diagnostic gold standard.
“Many AI-ECG studies in pulmonary hypertension use echocardiographic estimates of pulmonary artery pressure as the reference standard, even though right heart catheterization remains the diagnostic gold standard.”
Quote in the paperSubstantial claim- Rests on an assumption: Right heart catheterization remains the diagnostic gold standard for pulmonary hypertension.
Classified as probably not a substantial claim.
Interpretationnone givenCurrent evidence regarding AI-ECG workflow integration remains limited.
“Current evidence regarding AI-ECG workflow integration remains limited.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S4 (based). May combine two claims.
InterpretationreasoningReduced spatial information, variable device placement, motion artifact, and hardware differences may alter performance of portable AI-ECG.
“Reduced spatial information, variable device placement, motion artifact, and hardware differences may alter performance”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
InterpretationreasoningA clinically plausible saliency map does not establish that a model is well calibrated, unbiased, generalizable, or using a causal disease signal.
“A clinically plausible saliency map does not establish that a model is well calibrated, unbiased, generalizable, or using a causal disease signal.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S2 (checkable). May combine two claims.
InterpretationreasoningThe practical value of AI-ECG depends on how the result is delivered, who receives it, how urgent the alert is, and what diagnostic or referral pathway follows.
“The practical value of AI-ECG therefore depends on how the result is delivered, who receives it, how urgent the alert is, and what diagnostic or referral pathway follows.”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationcitationValidation in Kenyan outpatient facilities illustrates that AI-ECG could help prioritize scarce echocardiography and specialist resources and may extend cardiovascular screening beyond tertiary centers in settings where treatable disease is frequently recognized late.
“Validation in Kenyan outpatient facilities illustrates how AI-ECG could help prioritize scarce echocardiography and specialist resources, and it may extend cardiovascular screening beyond tertiary centers in settings where treatable disease is frequently recognized late [23].”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [23] Pandey, 2026, Artificial Intelligence Electrocardiogram and Left Ventricular Systolic Dysfunction in Kenya, JAMA Cardiol. source
Probably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationSaliency mapping in AI-ECG detection of hypertrophic cardiomyopathy has highlighted regions concentrated primarily in ventricular repolarization and ST-T segments.
“saliency mapping in AI-ECG detection of hypertrophic cardiomyopathy has highlighted regions concentrated primarily in ventricular repolarization and ST–T segments [48].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [48] Siontis, 2023, Saliency Maps Provide Insights into Artificial Intelligence-Based Electrocardiography Models for Detecting Hypertrophic Cardiomyopathy, J. Electrocardiol. source
Classified as probably not a substantial claim. May combine two claims.
InterpretationreasoningThe value of AI-ECG screening depends on disease prevalence, the availability of an effective confirmatory test and treatment, the capacity of the health system to evaluate positive results, and the consequences of false-positive and false-negative classifications.
“This benefit depends on disease prevalence, the availability of an effective confirmatory test and treatment, the capacity of the health system to evaluate positive results, and the consequences of false-positive and false-negative classifications.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Interpretationnone givenFrequent alerts may increase false-positive testing in portable AI-ECG.
“frequent alerts may increase false-positive testing”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim. May combine two claims.
InterpretationreasoningAI-ECG analysis generates quantitative outputs that may reflect broader physiologic states, including ventricular dysfunction, structural heart disease, metabolic abnormalities, biologic aging, and future mortality risk.
“AI-ECG analysis expands this role by generating quantitative outputs that may reflect broader physiologic states, including ventricular dysfunction, structural heart disease, metabolic abnormalities, biologic aging, and future mortality risk.”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationcitationEvidence from reduced-ejection-fraction models and the EAGLE trial suggests that AI-ECG screening can identify subclinical disease and influence diagnostic evaluation.
“Evidence from reduced-ejection-fraction models and the EAGLE trial suggests that this approach can identify subclinical disease and influence diagnostic evaluation [4,19].”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [4] Attia, 2019, Screening for Cardiac Contractile Dysfunction Using an Artificial Intelligence–Enabled Electrocardiogram, Nat. Med. source
- cites [19] Yao, 2021, Artificial Intelligence–Enabled Electrocardiograms for Identification of Patients with Low Ejection Fraction: A Pragmatic, Randomized Clinical Trial, Nat. Med. source
May combine two claims.
PremisecitationThe EAGLE trial showed that results delivered through the EHR can increase detection and targeted echocardiography, but it did not establish the optimal alert format, recipient, timing, threshold, or follow-up pathway.
“The EAGLE trial showed that results delivered through the EHR can increase detection and targeted echocardiography, but it did not establish the optimal alert format, recipient, timing, threshold, or follow-up pathway.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [19] Yao, 2021, Artificial Intelligence–Enabled Electrocardiograms for Identification of Patients with Low Ejection Fraction: A Pragmatic, Randomized Clinical Trial, Nat. Med. source
Classified as probably not a substantial claim.
InterpretationcitationPortable and limited-lead technologies may extend non-arrhythmic AI-ECG applications beyond conventional 12-lead acquisition.
“Portable and limited-lead technologies may extend non-arrhythmic AI-ECG applications beyond conventional 12-lead acquisition.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S2 (checkable).
InterpretationreasoningSuccessful integration of AI-ECG into clinical practice requires more than strong model performance.
“Successful integration of AI-ECG analysis into clinical practice requires more than strong model performance.”
Quote in the paperNot a substantial claimMay combine two claims.
Interpretationnone givenEvidence for hyperthyroidism, anemia, and sepsis remains more exploratory, with fewer independent validations and no prospective evidence that AI-ECG screening improves management or outcomes.
“Evidence for hyperthyroidism, anemia, and sepsis remains more exploratory, with fewer independent validations and no prospective evidence that AI-ECG screening improves management or outcomes.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S2 (checkable).
InterpretationreasoningInterpretability should not be equated with trustworthiness.
“Interpretability should not be equated with trustworthiness.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing).
InterpretationreasoningInterpretability is particularly important when AI-ECG is used for conditions that are not traditionally diagnosed by ECG, such as reduced ejection fraction, pulmonary hypertension, hyperkalemia, or mortality risk.
“Interpretability is particularly important when AI-ECG is used for conditions that are not traditionally diagnosed by ECG, such as reduced ejection fraction, pulmonary hypertension, hyperkalemia, or mortality risk.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable), S4 (based).
Interpretationnone givenAI-ECG has the potential to expand the ECG from a conventional diagnostic test into a screening and decision-support platform.
“AI-ECG has the potential to expand the ECG from a conventional diagnostic test into a screening and decision-support platform.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningCompression may introduce trade-offs between model size, inference speed, energy consumption, and diagnostic performance.
“compression may introduce trade-offs between model size, inference speed, energy consumption, and diagnostic performance”
Quote in the paperNot a substantial claimMay combine two claims.
InterpretationreasoningAttribution maps can be unstable across models, sensitive to preprocessing choices, and may not faithfully represent the true causal basis of a model's prediction.
“Attribution maps can be unstable across models, sensitive to preprocessing choices, and may not faithfully represent the true causal basis of a model’s prediction.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
InterpretationreasoningFalse negatives from AI-ECG screening could create inappropriate reassurance if clinicians rely on AI output over clinical judgment.
“false negatives could create inappropriate reassurance if clinicians rely on AI output over clinical judgment.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim.
InterpretationreasoningAccessibility of AI-ECG depends on more than the availability of the algorithm; a health system may be able to generate an AI-ECG risk score yet lack timely echocardiography, laboratory testing, specialist referral, or treatment capacity to act on the result.
“A health system may be able to generate an AI-ECG risk score yet lack timely echocardiography, laboratory testing, specialist referral, or treatment capacity to act on the result.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S2 (checkable).
InterpretationreasoningFor deployment decisions, external validation, subgroup performance, calibration, uncertainty estimates, failure-mode testing, and post-deployment monitoring may be more important than a visually convincing explanation.
“For deployment decisions, external validation, subgroup performance, calibration, uncertainty estimates, failure-mode testing, and post-deployment monitoring may be more important than a visually convincing explanation.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Premisenone givenMany high-performing AI-ECG models function as black boxes, meaning that the relationship between the input ECG waveform and the final prediction is not easily understood by clinicians.
“Many high-performing AI-ECG models function as “black boxes,” meaning that the relationship between the input ECG waveform and the final prediction is not easily understood by clinicians.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing), S4 (based).
Interpretationnone givenModels developed in tertiary centers may require local validation or recalibration before use in populations with different disease prevalence, ECG hardware, and referral patterns.
“Models developed in tertiary centers may also require local validation or recalibration before use in populations with different disease prevalence, ECG hardware, and referral patterns.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing), S4 (based).
Interpretationnone givenIf AI-ECG alerts are too frequent, poorly targeted, or disconnected from actionable next steps, clinicians may ignore them or view them as burdensome.
“If AI-ECG alerts are too frequent, poorly targeted, or disconnected from actionable next steps, clinicians may ignore them or view them as burdensome.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
InterpretationreasoningExplainability methods remain useful for detecting artifacts, comparing model attention with established ECG knowledge, and investigating unexpected errors, but they cannot substitute for prospective clinical validation.
“Explainability methods remain useful for detecting artifacts, comparing model attention with established ECG knowledge, and investigating unexpected errors, but they cannot substitute for prospective clinical validation.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S2 (checkable).
InterpretationreasoningWithout clearly assigned responsibility and measurable follow-up, even an accurate model may produce an ignored or clinically unactionable result.
“Without clearly assigned responsibility and measurable follow-up, even an accurate model may produce an ignored or clinically unactionable result.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationAutomation bias can occur when clinicians accept an automated recommendation without sufficient independent evaluation, particularly when the system is perceived as highly accurate or simplifies a complex decision.
“Automation bias can occur when clinicians accept an automated recommendation without sufficient independent evaluation, particularly when the system is perceived as highly accurate or simplifies a complex decision [46].”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [46] Abdelwanis, 2024, Exploring the Risks of Automation Bias in Healthcare Artificial Intelligence Applications: A Bowtie Analysis, J. Saf. Sci. Resil. source
May combine two claims.
InterpretationreasoningEvidence for AI-ECG in pulmonary hypertension remains less clinically mature than that for reduced ejection fraction because most studies are retrospective, reference standards are inconsistent, and no prospective trial has demonstrated that AI-guided screening reduces diagnostic delay or improves patient outcomes without producing excessive downstream testing.
“However, the evidence remains less clinically mature than that for reduced ejection fraction because most studies are retrospective, reference standards are inconsistent, and no prospective trial has demonstrated that AI-guided screening reduces diagnostic delay or improves patient outcomes without producing excessive downstream testing.”
Quote in the paperSubstantial claimClassified as probably not a substantial claim.
Interpretationnone givenECG patterns associated with PH may overlap with those caused by left-sided heart disease, chronic lung disease, conduction abnormalities, atrial fibrillation, or other causes of right ventricular strain.
“In addition, ECG patterns associated with PH may overlap with those caused by left-sided heart disease, chronic lung disease, conduction abnormalities, atrial fibrillation, or other causes of right ventricular strain.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S2 (checkable).
InterpretationreasoningEvidence is most persuasive when AI-ECG targets a condition such as reduced ejection fraction, for which a positive screen can lead to echocardiography and established treatment.
“The evidence is therefore most persuasive when AI-ECG targets a condition such as reduced ejection fraction, for which a positive screen can lead to echocardiography and established treatment.”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
InterpretationreasoningFederated learning may provide another pathway for expanding AI-ECG development across multiple institutions while limiting the need to centralize sensitive patient data.
“Federated learning may provide another pathway for expanding AI-ECG development across multiple institutions while limiting the need to centralize sensitive patient data.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim.
Interpretationnone givenHigh discrimination does not by itself establish clinical benefit for AI-ECG.
“However, high discrimination does not by itself establish clinical benefit.”
Quote in the paperSubstantial claimMay combine two claims.
Interpretationnone givenThe most mature evidence supports AI-ECG screening for reduced left ventricular ejection fraction, while applications involving structural heart disease, pulmonary hypertension, metabolic abnormalities, systemic disease, and broad prognostic assessment remain at different stages of validation.
“The most mature evidence supports AI-ECG screening for reduced left ventricular ejection fraction, while applications involving structural heart disease, pulmonary hypertension, metabolic abnormalities, systemic disease, and broad prognostic assessment remain at different stages of validation.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim. May combine two claims.
InterpretationreasoningAI analysis may support earlier detection, triage, and selection for confirmatory testing because ECGs are inexpensive and widely available.
“Because ECGs are inexpensive and widely available, AI analysis may support earlier detection, triage, and selection for confirmatory testing.”
Quote in the paperSubstantial claim- Rests on an assumption: ECGs are inexpensive and widely available.
Classified as probably not a substantial claim.
Interpretationnone givenDeep learning has expanded the potential of the 12-lead ECG beyond conventional rhythm and waveform interpretation.
“Deep learning has expanded the potential of the 12-lead ECG beyond conventional rhythm and waveform interpretation.”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S2 (checkable).
InterpretationreasoningPrognostic association alone is insufficient for AI-ECG outputs to be considered clinically useful digital biomarkers.
“AI-ECG outputs may ultimately function as digital biomarkers, but prognostic association alone is insufficient.”
Quote in the paperNot a substantial claimClassified as probably not a substantial claim. May combine two claims.
InterpretationreasoningThis approach could allow AI-ECG models to learn from larger and more diverse populations while reducing barriers associated with sharing identifiable health data.
“This approach could allow AI-ECG models to learn from larger and more diverse populations while reducing barriers associated with sharing identifiable health data.”
Quote in the paperSubstantial claim
The paper relies on this without support.
Conventional ECG changes in hyperkalemia can be inconsistent and may be absent even when serum potassium is dangerously elevated.
“Hyperkalemia is known to affect cardiac conduction and repolarization, but conventional ECG changes can be inconsistent and may be absent even when serum potassium is dangerously elevated.”
The paper relies on this without support.
AF may remain intermittent and undetected until complications such as stroke occur.
“Because AF may remain intermittent and undetected until complications such as stroke occur, AI-ECG could help select patients for ambulatory monitoring or closer rhythm surveillance.”
The paper relies on this without support.
HCM may be underdiagnosed, particularly in patients with subtle or nonspecific ECG findings.
“This was clinically important because HCM may be underdiagnosed, particularly in patients with subtle or nonspecific ECG findings, and earlier detection can prompt confirmatory imaging, family screening, risk stratification, and disease-specific management.”
The paper relies on this without support.
Cardiac amyloidosis diagnosis is often delayed.
“Cardiac amyloidosis is another clinically relevant application because diagnosis is often delayed, while earlier recognition has become increasingly important with the availability of disease-modifying therapy for transthyretin amyloid cardiomyopathy.”
The paper relies on this without support.
Delayed recognition of pulmonary hypertension is common.
“This finding is clinically important because delayed recognition of PH is common, and earlier identification may allow more timely echocardiography, specialist referral, and confirmatory hemodynamic testing when appropriate [37].”
The paper relies on this without support.
Structural heart disorders are relatively uncommon in general populations.
“Moreover, because these disorders are relatively uncommon in general populations, high discrimination does not necessarily translate into a high positive predictive value.”
The paper relies on this without support.
Right heart catheterization remains the diagnostic gold standard for pulmonary hypertension.
“Many AI-ECG studies in pulmonary hypertension use echocardiographic estimates of pulmonary artery pressure as the reference standard, even though right heart catheterization remains the diagnostic gold standard.”
The paper relies on this without support.
A risk estimate has limited clinical value unless it leads to a defined and beneficial action.
“a risk estimate has limited clinical value unless it leads to a defined and beneficial action.”
The paper relies on this without support.
Disease prevalence strongly influences positive predictive value.
“disease prevalence strongly influences positive predictive value”
The paper relies on this without support.
ECGs are inexpensive and widely available.
“Because ECGs are inexpensive and widely available”
The paper relies on this without support.
Wearable and portable devices have limited memory, processing capacity, and battery power, making deployment of large deep-learning models challenging.
“Wearable and portable devices have limited memory, processing capacity, and battery power, making deployment of large deep-learning models challenging.”
Cites
Collins, G. S., Moons, K. G. M., Dhiman, P., Riley, R. D., Beam, A. L., Van Calster, B., Ghassemi, M., Liu, X., Reitsma, J. B., van Smeden, M., et al. (2024) · BMJ · doi:10.1136/bmj-2023-078378 · Cited by 4,718 · cited 1× · see citing works
“Reporting frameworks such as TRIPOD+AII [55], CONSORT-AI [56], SPIRIT-AI [57], and DECIDE-AI [58] improve trans-parency, but adherence to reporting standards does not itself establish clinical usefulness.”
Attia, Z. I., Noseworthy, P. A., Lopez-Jimenez, F., Asirvatham, S. J., Deshmukh, A. J., Gersh, B. J., Carter, R. E., Yao, X., Rabinstein, A. A., Erickson, B. J., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31721-0 · Cited by 1,613 · see citing works
Liu, X., Cruz Rivera, S., Moher, D., Calvert, M. J., Denniston, A. K., The SPIRIT-AI and CONSORT-AI Working Group, SPIRIT-AI and CONSORT-AI Steering Group, Chan, A.-W., Darzi, A., Holmes, C., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-1034-x · Cited by 1,421 · see citing works
Attia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389 · see citing works
Vasey, B., Nagendran, M., Campbell, B., Clifton, D. A., Collins, G. S., Denaxas, S., Denniston, A. K., Faes, L., Geerts, B., Ibrahim, M., et al. (2022) · Nature Medicine · doi:10.1038/s41591-022-01772-9 · Cited by 1,039 · cited 1× · see citing works
“Reporting frameworks such as TRIPOD+AII [55], CONSORT-AI [56], SPIRIT-AI [57], and DECIDE-AI [58] improve trans-parency, but adherence to reporting standards does not itself establish clinical usefulness.”
Automatic diagnosis of the 12-lead ECG using a deep neural network
Ribeiro, A. H., Ribeiro, M. H., Paixão, G. M. M., Oliveira, D. M., Gomes, P. R., Canazart, J. A., Ferreira, M. P. S., Andersson, C. R., Macfarlane, P. W., Meira, W., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15432-4 · Cited by 894 · see citing works
Kligfield (2007) · doi:10.1161/circulationaha.106.180200 · Cited by 802 · see citing works
Cruz Rivera, S., Liu, X., Chan, A.-W., Denniston, A. K., Calvert, M. J., The SPIRIT-AI and CONSORT-AI Working Group, SPIRIT-AI and CONSORT-AI Steering Group, Darzi, A., Holmes, C., Yau, C., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-1037-7 · Cited by 748 · see citing works
Bias in medical AI: Implications for clinical decision-making
Cross, J. L., Choma, M. A., & Onofrey, J. A. (2024) · PLOS Digital Health · doi:10.1371/journal.pdig.0000651 · Cited by 607 · see citing works
Yao, X., Rushlow, D. R., Inselman, J. W., McCoy, R. G., Thacher, T. D., Behnken, E. M., Bernard, M. E., Rosas, S. L., Akfaly, A., Misra, A., et al. (2021) · Nature Medicine · doi:10.1038/s41591-021-01335-4 · Cited by 424 · see citing works
Ko, W.-Y., Siontis, K. C., Attia, Z. I., Carter, R. E., Kapa, S., Ommen, S. R., Demuth, S. J., Ackerman, M. J., Gersh, B. J., Arruda-Olson, A. M., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.12.030 · Cited by 404 · see citing works
Fahim, Y. A., Hasani, I. W., Kabba, S., & Ragab, W. M. (2025) · European Journal of Medical Research · doi:10.1186/s40001-025-03196-w · Cited by 329 · see citing works
Galloway, C. D., Valys, A. V., Shreibati, J. B., Treiman, D. L., Petterson, F. L., Gundotra, V. P., Albert, D. E., Attia, Z. I., Carter, R. E., Asirvatham, S. J., et al. (2019) · JAMA Cardiology · doi:10.1001/jamacardio.2019.0640 · Cited by 318 · see citing works
Prediction of mortality from 12-lead electrocardiogram voltage data using a deep neural network
Raghunath, S., Ulloa Cerna, A. E., Jing, L., vanMaanen, D. P., Stough, J., Hartzel, D. N., Leader, J. B., Kirchner, H. L., Stumpe, M. C., Hafez, A., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0870-z · Cited by 314 · see citing works
Raghunath, S., Pfeifer, J. M., Ulloa-Cerna, A. E., Nemani, A., Carbonati, T., Jing, L., vanMaanen, D. P., Hartzel, D. N., Ruhl, J. A., Lagerman, B. F., et al. (2021) · Circulation · doi:10.1161/circulationaha.120.047829 · Cited by 312 · see citing works
Teo, Z. L., Jin, L., Liu, N., Li, S., Miao, D., Zhang, X., Ng, W. Y., Tan, T. F., Lee, D. M., Chua, K. J., et al. (2024) · Cell Reports Medicine · doi:10.1016/j.xcrm.2024.101419 · Cited by 255 · see citing works
Electrocardiogram screening for aortic valve stenosis using artificial intelligence
Cohen-Shelly, M., Attia, Z. I., Friedman, P. A., Ito, S., Essayagh, B. A., Ko, W.-Y., Murphree, D. H., Michelena, H. I., Enriquez-Sarano, M., Carter, R. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab153 · Cited by 252 · see citing works
Deep Neural Network-Estimated Electrocardiographic Age as a Mortality Predictor
Lima, E. M., Ribeiro, A. H., Paixão, G. M. M., Ribeiro, M. H., Pinto-Filho, M. M., Gomes, P. R., Oliveira, D. M., Sabino, E. C., Duncan, B. B., Giatti, L., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-25351-7 · Cited by 249 · see citing works
Goto, S., Mahara, K., Beussink-Nelson, L., Ikura, H., Katsumata, Y., Endo, J., Gaggin, H. K., Shah, S. J., Itabashi, Y., MacRae, C. A., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-22877-8 · Cited by 245 · see citing works
Navigating the EU AI Act: implications for regulated digital medical products
Aboy, M., Minssen, T., & Vayena, E. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01232-3 · Cited by 225 · see citing works
Deep Learning–Based Algorithm for Detecting Aortic Stenosis Using Electrocardiography
Kwon, J., Lee, S. Y., Jeon, K., Lee, Y., Kim, K., Park, J., Oh, B., & Lee, M. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.119.014717 · Cited by 224 · see citing works
Noseworthy, P. A., Attia, Z. I., Brewer, L. C., Hayes, S. N., Yao, X., Kapa, S., Friedman, P. A., & Lopez-Jimenez, F. (2020) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.119.007988 · Cited by 220 · see citing works
Automated and interpretable patient ECG profiles for disease detection, tracking, and discovery
Tison, G. H., Zhang, J., Delling, F. N., & Deo, R. C. (2019) · Circulation: Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.118.005289 · Cited by 208 · see citing works
Adedinsewo, D., Carter, R. E., Attia, Z., Johnson, P., Kashou, A. H., Dugan, J. L., Albus, M., Sheele, J. M., Bellolio, F., Friedman, P. A., et al. (2020) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.120.008437 · Cited by 169 · see citing works
Bachtiger, P., Petri, C. F., Scott, F. E., Ri Park, S., Kelshiker, M. A., Sahemey, H. K., Dumea, B., Alquero, R., Padam, P. S., Hatrick, I. R., et al. (2022) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00256-9 · Cited by 167 · see citing works
Artificial Intelligence–Enhanced Electrocardiogram for the Early Detection of Cardiac Amyloidosis
Grogan, M., Lopez-Jimenez, F., Cohen-Shelly, M., Dispenzieri, A., Attia, Z. I., Abou Ezzedine, O. F., Lin, G., Kapa, S., Borgeson, D. D., Friedman, P. A., et al. (2021) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2021.04.023 · Cited by 166 · see citing works
Abdelwanis, M., Alarafati, H. K., Tammam, M. M. S., & Simsekler, M. C. E. (2024) · Journal of Safety Science and Resilience · doi:10.1016/j.jnlssr.2024.06.001 · Cited by 137 · see citing works
Detecting structural heart disease from electrocardiograms using AI
Poterucha, T. J., Jing, L., Ricart, R. P., Adjei-Mosi, M., Finer, J., Hartzel, D., Kelsey, C., Long, A., Rocha, D., Ruhl, J. A., et al. (2025) · Nature · doi:10.1038/s41586-025-09227-0 · Cited by 116 · see citing works
Lin, C.-S., Lin, C., Fang, W.-H., Hsu, C.-J., Chen, S.-J., Huang, K.-H., Lin, W.-S., Tsai, C.-S., Kuo, C.-C., Chau, T., et al. (2020) · JMIR Medical Informatics · doi:10.2196/15931 · Cited by 109 · see citing works
Artificial intelligence for early prediction of pulmonary hypertension using electrocardiography
Kwon, J.-M., Kim, K.-H., Medina-Inojosa, J., Jeon, K.-H., Park, J., & Oh, B.-H. (2020) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2020.04.009 · Cited by 108 · see citing works
Artificial Intelligence-Enabled ECG for Left Ventricular Diastolic Function and Filling Pressure
Lee, E., Ito, S., Miranda, W. R., Lopez-Jimenez, F., Kane, G. C., Asirvatham, S. J., Noseworthy, P. A., Friedman, P. A., Carter, R. E., Borlaug, B. A., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-023-00993-7 · Cited by 106 · see citing works
Kwon, J.-M., Kim, K.-H., Eisen, H. J., Cho, Y., Jeon, K.-H., Lee, S. Y., Park, J., & Oh, B.-H. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaa015 · Cited by 82 · see citing works
External validation of a deep learning electrocardiogram algorithm to detect ventricular dysfunction
Attia, I. Z., Tseng, A. S., Benavente, E. D., Medina‐Inojosa, J. R., Clark, T. G., Malyutina, S. K., Kapa, S., Schirmer, H., Kudryavtsev, A. V., Noseworthy, P. A., et al. (2021) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.12.065 · Cited by 82 · see citing works
Shumba, A.-T., Montanaro, T., Sergi, I., Bramanti, A., Ciccarelli, M., Rispoli, A., Carrizzo, A., De Vittorio, M., & Patrono, L. (2023) · Sensors · doi:10.3390/s23156896 · Cited by 74 · see citing works
Kashou, A. H., Medina-Inojosa, J. R., Noseworthy, P. A., Rodeheffer, R. J., Lopez-Jimenez, F., Attia, I. Z., Kapa, S., Scott, C. G., Lee, A. T., Friedman, P. A., et al. (2021) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2021.02.029 · Cited by 66 · see citing works
Lin, C., Chau, T., Lin, C.-S., Shang, H.-S., Fang, W.-H., Lee, D.-J., Lee, C.-C., Tsai, S.-H., Wang, C.-H., & Lin, S.-H. (2022) · npj Digital Medicine · doi:10.1038/s41746-021-00550-0 · Cited by 62 · see citing works
Explaining Deep Learning for ECG Analysis: Building Blocks for Auditing and Knowledge Discovery
Wagner, P., Mehari, T., Haverkamp, W., & Strodthoff, N. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108525 · Cited by 48 · see citing works
Harmon, D. M., Mangold, K., Baez Suarez, A., Scott, C. G., Murphree, D. H., Malik, A., Attia, Z. I., Lopez-Jimenez, F., Friedman, P. A., Dispenzieri, A., et al. (2023) · JACC: Advances · doi:10.1016/j.jacadv.2023.100612 · Cited by 47 · see citing works
Liu, C.-M., Shih, E. S. C., Chen, J.-Y., Huang, C.-H., Wu, I.-C., Chen, P.-F., Higa, S., Yagi, N., Hu, Y.-F., Hwang, M.-J., et al. (2022) · JACC: Asia · doi:10.1016/j.jacasi.2022.02.008 · Cited by 46 · see citing works
Siontis, K. C., Wieczorek, M. A., Maanja, M., Hodge, D. O., Kim, H.-K., Lee, H.-J., Lee, H., Lim, J., Park, C. S., Ariga, R., et al. (2024) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztae029 · Cited by 44 · see citing works
Schepart, A., Burton, A., Durkin, L., Fuller, A., Charap, E., Bhambri, R., & Ahmad, F. S. (2023) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2023.04.003 · Cited by 40 · see citing works
Qiu, Y., Guo, H., Wang, S., Yang, S., Peng, X., Xiayao, D., Chen, R., Yang, J. M., Liu, J., Li, M., et al. (2024) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-024-02616-x · Cited by 39 · see citing works
Siontis, K. C., Suárez, A. B., Sehrawat, O., Ackerman, M. J., Attia, Z. I., Friedman, P. A., Noseworthy, P. A., & Maanja, M. (2023) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2023.07.002 · Cited by 38 · see citing works
An electrocardiogram-based AI algorithm for early detection of pulmonary hypertension
DuBrock, H. M., Wagner, T. E., Carlson, K., Carpenter, C. L., Awasthi, S., Attia, Z. I., Frantz, R. P., Friedman, P. A., Kapa, S., Annis, J., et al. (2024) · European Respiratory Journal · doi:10.1183/13993003.00192-2024 · Cited by 38 · see citing works
Compressed Deep Learning to Classify Arrhythmia in an Embedded Wearable Device
Lee, K.-S., Park, H.-J., Kim, J. E., Kim, H. J., Chon, S., Kim, S., Jang, J., Kim, J.-K., Jang, S., Gil, Y., et al. (2022) · Sensors · doi:10.3390/s22051776 · Cited by 36 · see citing works
Harmon, D. M., Carter, R. E., Cohen-Shelly, M., Svatikova, A., Adedinsewo, D. A., Noseworthy, P. A., Kapa, S., Lopez-Jimenez, F., Friedman, P. A., & Attia, Z. I. (2022) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztac028 · Cited by 35 · see citing works
Vaid, A., Argulian, E., Lerakis, S., Beaulieu-Jones, B. K., Krittanawong, C., Klang, E., Lampert, J., Reddy, V. Y., Narula, J., Nadkarni, G. N., et al. (2023) · Communications Medicine · doi:10.1038/s43856-023-00240-w · Cited by 30 · see citing works
Deep-Learning Model for Screening Sepsis Using Electrocardiography
Kwon, J.-M., Lee, Y. R., Jung, M.-S., Lee, Y.-J., Jo, Y.-Y., Kang, D.-Y., Lee, S. Y., Cho, Y.-H., Shin, J.-H., Ban, J.-H., et al. (2021) · Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine · doi:10.1186/s13049-021-00953-8 · Cited by 28 · see citing works
End-to-end risk prediction of atrial fibrillation from the 12-Lead ECG by deep neural networks
Habineza, T., Ribeiro, A. H., Gedon, D., Behar, J. A., Ribeiro, A. H., & Schön, T. B. (2023) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2023.09.011 · Cited by 23 · see citing works
Jain, S. S., Goto, S., Hall, J. L., Khan, S. S., MacRae, C. A., Ofori, C., Pegus, C., Pencina, M., Peterson, E. D., Schwamm, L. H., et al. (2025) · Circulation · doi:10.1161/cir.0000000000001400 · Cited by 23 · see citing works
König, S., Hohenstein, S., Nitsche, A., Pellissier, V., Leiner, J., Stellmacher, L., Hindricks, G., & Bollmann, A. (2024) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztad081 · Cited by 21 · see citing works
Weimann, K., & Conrad, T. O. F. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3427787 · Cited by 19 · see citing works
Desai, M. Y., Jadam, S., Abusafia, M., Rutkowski, K., Ospina, S., Gaballa, A., Sultana, S., Thamilarasan, M., Xu, B., & Popovic, Z. B. (2025) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2025.02.024 · Cited by 19 · see citing works
Oikonomou, E. K., Batinica, B., Dhingra, L. S., Aminorroaya, A., Coppi, A. C., & Khera, R. (2026) · NEJM AI · doi:10.1056/aioa2500588 · Cited by 17 · see citing works
Hong, D., Song, S.-H., Shin, H., Bak, M., Kim, J., Kim, D., Kim, J. Y., Yang, J. H., Park, S.-J., Choi, J.-O., et al. (2025) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaf080 · Cited by 14 · see citing works
Challenges and Potential of Using Digital Biomarkers in Healthcare and Clinical Trials
Lieberwirth, J. K., Mittermaier, M., & Stern, A. D. (2026) · Communications Medicine · doi:10.1038/s43856-026-01450-8 · Cited by 13 · see citing works
Electrocardiographic Biomarker Based on Machine Learning for Detecting Overt Hyperthyroidism
Choi, B., Jang, J. H., Son, M., Lee, M. S., Jo, Y. Y., Jeon, J. Y., Jin, U., Soh, M., Park, R. W., & Kwon, J. M. (2022) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztac013 · Cited by 12 · see citing works
Hsieh, P.-H., Lin, C., Lin, C.-S., Liu, W.-T., Lin, T.-K., Tsai, D.-J., Hung, Y.-J., Chen, Y.-H., Lin, C.-Y., Lin, S.-H., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01735-7 · Cited by 11 · see citing works
Lin, C., Chen, C.-C., Chau, T., Lin, C.-S., Tsai, S.-H., Lee, D.-J., Lee, C.-C., Shang, H.-S., & Lin, S.-H. (2022) · Clinica Chimica Acta · doi:10.1016/j.cca.2022.09.021 · Cited by 10 · see citing works
Lin, C., Kuo, F.-C., Chau, T., Shih, J.-H., Lin, C.-S., Chen, C.-C., Lee, C.-C., & Lin, S.-H. (2024) · Communications Medicine · doi:10.1038/s43856-024-00472-4 · Cited by 8 · see citing works
Naser, J. A., Lee, E., Lopez-Jimenez, F., Noseworthy, P. A., Latif, O. S., Friedman, P. A., Lin, G., Oh, J. K., Scott, C. G., Pislaru, S. V., et al. (2024) · JACC: Advances · doi:10.1016/j.jacadv.2024.101179 · Cited by 8 · see citing works
Bollepalli, S. C., Isselbacher, E. M., Singh, J. P., & Armoundas, A. A. (2025) · npj Cardiovascular Health · doi:10.1038/s44325-025-00087-1 · Cited by 8 · see citing works
Artificial Intelligence Electrocardiogram and Left Ventricular Systolic Dysfunction in Kenya
Pandey, A., Keshvani, N., Segar, M. W., Kwon, J.-M., Lee, H. S., Bhograj, C., Mashilane, K. I., Jain, N., Mwiti, W., Wambari, E., et al. (2026) · JAMA Cardiology · doi:10.1001/jamacardio.2026.0908 · Cited by 7 · see citing works
Arends, B. K. O., van Amsterdam, W. A. C., van der Harst, P., van Smeden, M., van Es, R., & van de Leur, R. R. (2026) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztag038 · Cited by 6 · see citing works
Armoundas, A. A., Silva, J. N. A., Baykaner, T., Bhatia, N. K., Isakadze, N., Pundi, K. N., Siontis, K. C., Lorvidhaya, P., Andrade, J. G., Kalscheur, M. M., et al. (2026) · Heart Rhythm · doi:10.1016/j.hrthm.2026.04.013 · Cited by 4 · see citing works
Yang, C.-C., Lin, C.-S., Lin, C., Liu, W.-T., Lai, Z.-Y., & Chuang, Y.-J. (2026) · Internal and Emergency Medicine · doi:10.1007/s11739-025-04209-6 · Cited by 3 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- Sattar, Y., and Chhabra, L. (2026, July 17). Electrocardiogram, StatPearls, Available online: https://www.ncbi.nlm.nih.gov/books/NBK549803/.
- Authors
- Shaulian, S., Zeltser, R., & Makaryus, A. N.
- Affiliations
- New York Institute of Technology (US)
- Northwell Health (US)
- Corresponding author
- Makaryus, Amgad N.
- Venue
- Diagnostics
- Publisher
- MDPI AG
- Published
- 2026-09-03
- Volume
- 16
- Issue
- 17
- Pages
- 2834
- ISSN
- 2075-4418 (ISSN-L)
- PMC
- PMC13565729
- OpenAlex
- W7207520242
- Semantic Scholar
- 36c31abbff96f977ead36f1660b11b1f39969b9a
- Cited by
- 0
- References
- 65
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Diagnostics (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Computer Science › Artificial Intelligence › Machine Learning in Healthcare
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- 12-lead ECG, deep learning, left ventricular ejection fraction, hypertrophic cardiomyopathy, valvular heart disease, cardiac amyloidosis, pulmonary hypertension, hyperkalemia, hyperthyroidism, anemia, sepsis, biological age estimation, mortality prediction, disease screening, clinical decision support, external validation, implementation barriers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-27.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-27.
Cited sources are checked by gpt-6-sol.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review