CoChat

Deep Learning Algorithm for Automated Cardiac Murmur Detection via a Digital Stethoscope Platform

Open access
Chorba, John S., Shapiro, Avi M., Le, Le, Maidens, John, Prince, John, Pham, Steve, Kanzawa, Mia M., Barbosa, Daniel N., Currie, Caroline, Brooks, Catherine, White, Brent E., Huskin, Anna, Paek, Jason, Geocaris, Jack, Elnathan, Dinatu, Ronquillo, Ria, Kim, Roy, Alam, Zenith H., Mahadevan, Vaikom S., Fuller, Sophie G., Stalker, Grant W., Bravo, Sara A., Jean, Dina, Lee, John J., Gjergjindreaj, Medeona, Mihos, Christos G., Forman, Steven T., Venkatraman, Subramaniam, McCarthy, Patrick M., Thomas, James D. · 2021 · Journal of the American Heart Association
Cited by 146

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Background: Clinicians vary markedly in their ability to detect murmurs during cardiac auscultation and identify the underlying pathological features. Deep learning approaches have shown promise in medicine by transforming collected data into clinically significant information. The objective of this research is to assess the performance of a deep learning algorithm to detect murmurs and clinically significant valvular heart disease using recordings from a commercial digital stethoscope platform. Methods and Results: Using >34 hours of previously acquired and annotated heart sound recordings, we trained a deep neural network to detect murmurs. To test the algorithm, we enrolled 962 patients in a clinical study and collected recordings at the 4 primary auscultation locations. Ground truth was established using patient echocardiograms and annotations by 3 expert cardiologists. Algorithm performance for detecting murmurs has sensitivity and specificity of 76.3% and 91.4%, respectively. By omitting softer murmurs, those with grade 1 intensity, sensitivity increased to 90.0%. Application of the algorithm at the appropriate anatomic auscultation location detected moderate‐to‐severe or greater aortic stenosis, with sensitivity of 93.2% and specificity of 86.0%, and moderate‐to‐severe or greater mitral regurgitation, with sensitivity of 66.2% and specificity of 94.6%. Conclusions: The deep learning algorithm’s ability to detect murmurs and clinically significant aortic stenosis and mitral regurgitation is comparable to expert cardiologists based on the annotated subset of our database. The findings suggest that such algorithms would have utility as front‐line clinical support tools to aid clinicians in screening for cardiac murmurs caused by valvular heart disease. Registration: URL: https://clinicaltrials.gov ; Unique Identifier: NCT03458806.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/jaha.120.019905

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 146

Metadata

Authors
Chorba, J. S., Shapiro, A. M., Le, L., Maidens, J., Prince, J., Pham, S., Kanzawa, M. M., Barbosa, D. N., Currie, C., Brooks, C., White, B. E., Huskin, A., Paek, J., Geocaris, J., Elnathan, D., Ronquillo, R., Kim, R., Alam, Z. H., Mahadevan, V. S., Fuller, S. G., Stalker, G. W., Bravo, S. A., Jean, D., Lee, J. J., Gjergjindreaj, M., Mihos, C. G., Forman, S. T., Venkatraman, S., McCarthy, P. M., & Thomas, J. D.
Venue
Journal of the American Heart Association
Published
2021-05-04
Volume
10
Issue
9
Pages
e019905-e019905
ISSN
2047-9980 (ISSN-L)
OpenAlex
W3159550770
Cited by
146
References
8
FWCI
12.91
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep Learning Algorithm for Automated Cardiac Murmur Detection via a Digital Stethoscope Platform. https://app.cochat.ai/papers/10.1161/jaha.120.019905
The paper
Chorba, J. S., Shapiro, A. M., Le, L., Maidens, J., Prince, J., Pham, S., Kanzawa, M. M., Barbosa, D. N., Currie, C., Brooks, C., White, B. E., Huskin, A., Paek, J., Geocaris, J., Elnathan, D., Ronquillo, R., Kim, R., Alam, Z. H., Mahadevan, V. S., . . . Thomas, J. D. (2021). Deep Learning Algorithm for Automated Cardiac Murmur Detection via a Digital Stethoscope Platform. Journal of the American Heart Association. https://doi.org/10.1161/jaha.120.019905

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.