Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 261

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Accuracy of Prediction Instruments for Diagnosing Large Vessel Occlusion in Individuals With Suspected Stroke: A Systematic Review for the 2018 Guidelines for the Early Management of Patients With Acute Ischemic Stroke

Open access
Smith, Eric E., Kent, David M., Bulsara, Ketan R., Leung, Lester Y., Lichtman, Judith H., Reeves, Mathew J., Towfighi, Amytis, Whiteley, William N., Zahuranec, Darin B. · 2018 · Stroke

Abstract

Introduction—: Endovascular thrombectomy is a highly efficacious treatment for large vessel occlusion (LVO). LVO prediction instruments, based on stroke signs and symptoms, have been proposed to identify stroke patients with LVO for rapid transport to endovascular thrombectomy–capable hospitals. This evidence review committee was commissioned by the American Heart Association/American Stroke Association to systematically review evidence for the accuracy of LVO prediction instruments. Methods—: Medline, Embase, and Cochrane databases were searched on October 27, 2016. Study quality was assessed with the Quality Assessment of Diagnostic Accuracy-2 tool. Results—: Thirty-six relevant studies were identified. Most studies (21 of 36) recruited patients with ischemic stroke, with few studies in the prehospital setting (4 of 36) and in populations that included hemorrhagic stroke or stroke mimics (12 of 36). The most frequently studied prediction instrument was the National Institutes of Health Stroke Scale. Most studies had either some risk of bias or unclear risk of bias. Reported discrimination of LVO mostly ranged from 0.70 to 0.85, as measured by the C statistic. In meta-analysis, sensitivity was as high as 87% and specificity was as high as 90%, but no threshold on any instruments predicted LVO with both high sensitivity and specificity. With a positive LVO prediction test, the probability of LVO could be 50% to 60% (depending on the LVO prevalence in the population), but the probability of LVO with a negative test could still be ≥10%. Conclusions—: No scale predicted LVO with both high sensitivity and high specificity. Systems that use LVO prediction instruments for triage will miss some patients with LVO and milder stroke. More prospective studies are needed to assess the accuracy of LVO prediction instruments in the prehospital setting in all patients with suspected stroke, including patients with hemorrhagic stroke and stroke mimics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/str.0000000000000160

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 261

Metadata

Authors
Smith, E. E., Kent, D. M., Bulsara, K. R., Leung, L. Y., Lichtman, J. H., Reeves, M. J., Towfighi, A., Whiteley, W. N., & Zahuranec, D. B.
Venue
Stroke
Published
2018-03
Volume
49
Issue
3
Pages
e111-e122
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2792877302
Cited by
261
References
26
FWCI
6.76
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of Prediction Instruments for Diagnosing Large Vessel Occlusion in Individuals With Suspected Stroke: A Systematic Review for the 2018 Guidelines for the Early Management of Patients With Acute Ischemic Stroke. https://app.cochat.ai/papers/10.1161/str.0000000000000160
The paper
Smith, E. E., Kent, D. M., Bulsara, K. R., Leung, L. Y., Lichtman, J. H., Reeves, M. J., Towfighi, A., Whiteley, W. N., & Zahuranec, D. B. (2018). Accuracy of Prediction Instruments for Diagnosing Large Vessel Occlusion in Individuals With Suspected Stroke: A Systematic Review for the 2018 Guidelines for the Early Management of Patients With Acute Ischemic Stroke. Stroke. https://doi.org/10.1161/str.0000000000000160

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.