Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 405

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

A Novel, Self-Expanding, Nitinol Stent in Medically Refractory Intracranial Atherosclerotic Stenoses: The Wingspan Study

Bose, Arani, Hartmann, Marius, Henkes, Hans, Liu, Hon Man, Teng, Michael M.H., Szikora, Istvan, Berlis, Ansgar, Reul, Jurgen, Yu, Simon C.H., Forsting, Michael, Lui, Matt, Lim, Winston, Sit, Siu Po·2007·Stroke

Abstract

Background and Purpose— The purpose of this study was to assess the safety and performance of the Wingspan stent system and Gateway percutaneous transluminal angioplasty balloon catheter in the treatment of high-grade, intracranial atherosclerotic lesions in patients who had failed medical therapy. Methods— In this prospective, multicenter, single-arm study, medically refractory patients with a modified Rankin score ≤3 and recurrent symptoms attributable to angiographically demonstrated intracranial stenosis ≥50% in a vessel 2.5 to 4.5 mm in diameter were enrolled. Intracranial lesions were predilated with an undersized Gateway balloon catheter to 80% of the native vessel diameter, followed by deployment of the self-expanding Wingspan stent to facilitate further remodeling of the atherosclerotic plaque and to maintain vessel patency. Neurologic examinations and angiograms were performed at 6 months after the procedure. Results— Among the 45 patients enrolled, the degree of stenosis was reduced from a baseline of 74.9±9.8% to 31.9±13.6% after stenting and 28±23.2% at the 6-month follow-up. The 30-day composite ipsilateral stroke/death rate was 4.5% (2/44); at the 6-month follow-up, the ipsilateral stroke/death rate was 7.0%, the rate for all strokes was 9.7%, and all-cause mortality was 2.3%. Physician-reported follow-up in 43 patients (average of 13 months) conducted outside the study protocol (not adjudicated by the clinical event committee) reported 1 additional ipsilateral stroke. Conclusions— In medically refractory patients with high-grade intracranial atherosclerotic stenoses, a new treatment paradigm involving predilation with an undersized Gateway percutaneous transluminal angioplasty balloon catheter and placement of a self-expanding Wingspan stent system appears to be safe, may facilitate remodeling, and may contribute to favorable angiographic outcomes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/strokeaha.106.477711

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 405

Metadata

Authors
Bose, A., Hartmann, M., Henkes, H., Liu, H. M., Teng, M. M. H., Szikora, I., Berlis, A., Reul, J., Yu, S. C. H., Forsting, M., Lui, M., Lim, W., & Sit, S. P.
Venue
Stroke
Published
2007-05
Volume
38
Issue
5
Pages
1531-1537
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2140077977
Cited by
405
References
20
FWCI
30.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel, Self-Expanding, Nitinol Stent in Medically Refractory Intracranial Atherosclerotic Stenoses: The Wingspan Study. https://app.cochat.ai/papers/10.1161/strokeaha.106.477711
The paper
Bose, A., Hartmann, M., Henkes, H., Liu, H. M., Teng, M. M. H., Szikora, I., Berlis, A., Reul, J., Yu, S. C. H., Forsting, M., Lui, M., Lim, W., & Sit, S. P. (2007). A Novel, Self-Expanding, Nitinol Stent in Medically Refractory Intracranial Atherosclerotic Stenoses: The Wingspan Study. Stroke. https://doi.org/10.1161/strokeaha.106.477711

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.