Background and Purpose— Ultrasound transiently expands perflutren-lipid microspheres (μS), transmitting energy momentum to surrounding fluids. We report a pilot safety/feasibility study of ultrasound-activated μS with systemic tissue plasminogen activator (tPA). Methods— Stroke subjects treated within 3 hours had abnormal Thrombolysis in Brain Ischemia (TIBI) residual flow grades 0 to 3 before tPA on transcranial Doppler (TCD). Randomization included Controls (tPA+TCD) or Target (tPA+TCD+2.8 mL μS). The primary safety end point was symptomatic intracranial hemorrhage (sICH) with worsening by ≥4 NIHSS points within 72 hours. Results— Fifteen subjects were randomized 3:1 to Target, n=12 or Control, n=3. After treatment, asymptomatic ICH occurred in 3 Target and 1 Control, and sICH was not seen in any study subject. μS reached MCA occlusions in all Target subjects at velocities higher than surrounding residual red blood cell flow: 39.8±11.3 vs 28.8±13.8 cm/s, P<0.001. In 75% of subjects, μS permeated to areas with no pretreatment residual flow, and in 83% residual flow velocity improved at a median of 30 minutes from start of μS infusion (range 30 s to 120 minutes) by a median of 17 cm/s (118% above pretreatment values). To provide perspective, current study recanalization rates were compared with the tPA control arm of the CLOTBUST trial: complete recanalization 50% versus 18%, partial 33% versus 33%, none 17% versus 49%, P =0.028. At 2 hours, sustained complete recanalization was 42% versus 13%, P =0.003, and NIHSS scores 0 to 3 were reached by 17% versus 8%, P =0.456. Conclusions— Perflutren μS reached and permeated beyond intracranial occlusions with no increase in sICH after systemic thrombolysis suggesting feasibility of further μS dose-escalation studies and development of drug delivery to tissues with compromised perfusion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/strokeaha.107.505727

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 164

Metadata

Authors
Alexandrov, A. V., Mikulik, R., Ribo, M., Sharma, V. K., Lao, A. Y., Tsivgoulis, G., Sugg, R. M., Barreto, A., Sierzenski, P., Malkoff, M. D., & Grotta, J. C.
Venue
Stroke
Published
2008-05
Volume
39
Issue
5
Pages
1464-1469
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2002892867
Cited by
164
References
1
FWCI
10.51
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Pilot Randomized Clinical Safety Study of Sonothrombolysis Augmentation With Ultrasound-Activated Perflutren-Lipid Microspheres for Acute Ischemic Stroke. https://app.cochat.ai/papers/10.1161/strokeaha.107.505727
The paper
Alexandrov, A. V., Mikulik, R., Ribo, M., Sharma, V. K., Lao, A. Y., Tsivgoulis, G., Sugg, R. M., Barreto, A., Sierzenski, P., Malkoff, M. D., & Grotta, J. C. (2008). A Pilot Randomized Clinical Safety Study of Sonothrombolysis Augmentation With Ultrasound-Activated Perflutren-Lipid Microspheres for Acute Ischemic Stroke. Stroke. https://doi.org/10.1161/strokeaha.107.505727

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.