CoChat

Diagnostic Accuracy of Magnetic Resonance Angiography for Internal Carotid Artery Disease: A Systematic Review and Meta-Analysis

Open access
Debrey, Sarah M., Yu, Hua, Lynch, John K., Lövblad, Karl-Olof, Wright, Violet L., Janket, Sok-Ja D., Baird, Alison E. · 2008 · Stroke
Cited by 178

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background and Purpose— Accurate diagnosis of the degree of internal carotid artery (ICA) stenosis is needed for decisions regarding optimal stroke prevention. Noninvasive magnetic resonance angiography (MRA) is being proposed and used as a replacement for the gold standard, intra-arterial angiography. Our purpose was to perform a systematic review and diagnostic meta-analysis to determine the sensitivity and specificity of time-of-flight (TOF) MRA and contrast-enhanced (CE) MRA for the detection of (1) high-grade (≥70% to 99%) ICA stenoses; (2) ICA occlusions; (3) moderately severe (50% to 69%) ICA stenoses; and (4) compare the overall accuracy of the 2 MRA techniques. Methods— The medical literature on MRA and the diagnosis of ICA steno-occlusive disease was reviewed through the PubMed, EMBASE, and SCOPUS databases. All publication years were included through to November 2006. Studies were eligible for inclusion if they compared the accuracy of TOF or CE MRA for the detection of ICA disease against intra-arterial angiography and reported sufficient data. Results— The overall sensitivity of TOF MRA for the detection of ≥70% to 99% ICA stenoses was 91.2% (95% CI: 88.9% to 93.1%) with a specificity of 88.3% (86.7% to 89.7%), whereas the sensitivity of CE MRA was 94.6% (92.4% to 96.4%) with a specificity of 91.9% (90.3% to 93.4%). For the detection of ICA occlusions, the sensitivity of TOF MRA was 94.5% (91.2% to 96.8%) and the specificity was 99.3% (98.9% to 99.6%), whereas the sensitivity and specificity values for CE MRA were 99.4% (96.8% to 100%) and 99.6% (99.2% to 99.9%), respectively. For moderately severe (50% to 69%) stenoses, TOF MRA had a sensitivity of only 37.9% (29.3% to 47.1%) and a specificity of 92.1% (89.6% to 94.1%); for CE MRA, the pooled sensitivity value was somewhat better at 65.9% (57.0% to 74.0%), whereas the specificity was 93.5% (91.3% to 95.3%). Conclusions— TOF MRA and CE MRA showed high accuracy for the detection of high-grade ICA stenoses and occlusions with CE MRA having the edge over TOF MRA, but had only poor (TOF MRA) to fair (CE MRA) sensitivity for the detection of moderately severe stenoses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/strokeaha.107.509877

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 178

Metadata

Authors
Debrey, S. M., Yu, H., Lynch, J. K., Lövblad, K.-O., Wright, V. L., Janket, S.-J. D., & Baird, A. E.
Venue
Stroke
Published
2008-08
Volume
39
Issue
8
Pages
2237-2248
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W1996383835
Cited by
178
References
5
FWCI
12.80
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.