Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 172

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Stent Placement in Acute Cerebral Artery Occlusion: Use of a Self-Expandable Intracranial Stent for Acute Stroke Treatment

Open access
Brekenfeld, Caspar, Schroth, Gerhard, Mattle, Heinrich P., Do, Do-Dai, Remonda, Luca, Mordasini, Pasquale, Arnold, Marcel, Nedeltchev, Krassen, Meier, Niklaus, Gralla, Jan · 2009 · Stroke

Abstract

Background and Purpose— Stent placement has been applied in small case series as a rescue therapy in combination with different thrombolytic agents, percutaneous balloon angioplasty (PTA), and mechanical thromboembolectomy (MT) in acute stroke treatment. These studies report a considerable mortality and a high rate of intracranial hemorrhages when balloon-mounted stents were used. This study was performed to evaluate feasibility, efficacy, and safety of intracranial artery recanalization for acute ischemic stroke using a self-expandable stent. Methods— All patients treated with an intracranial stent for acute cerebral artery occlusion were included. Treatment comprised intraarterial thrombolysis, thromboaspiration, MT, PTA, and stent placement. Recanalization result was assessed by follow-up angiography immediately after stent placement. Complications related to the procedure and outcome at 3 months were assessed. Results— Twelve patients (median NIHSS 14, mean age 63 years) were treated with intracranial stents for acute ischemic stroke. Occlusions were located in the posterior vertebrobasilar circulation (n=6) and in the anterior circulation (n=6). Stent placement was feasible in all procedures and resulted in partial or complete recanalization (TIMI 2/3) in 92%. No vessel perforations, subarachnoid, or symptomatic intracerebral hemorrhages occurred. One dissection was found after thromboaspiration and PTA. Three patients (25%) had a good outcome (mRS 0 to 2), 3 (25%) a moderate outcome (mRS 3), and 6 (50%) a poor outcome (mRS 4 to 6). Mortality was 33.3%. Conclusions— Intracranial placement of a self-expandable stent for acute ischemic stroke is feasible and seems to be safe to achieve sufficient recanalization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/strokeaha.108.533810

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 172

Metadata

Authors
Brekenfeld, C., Schroth, G., Mattle, H. P., Do, D.-D., Remonda, L., Mordasini, P., Arnold, M., Nedeltchev, K., Meier, N., & Gralla, J.
Venue
Stroke
Published
2009-03
Volume
40
Issue
3
Pages
847-852
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2159931276
Cited by
172
References
2
FWCI
18.10
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.