Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 236

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Ten-Year Detection Rate of Brain Arteriovenous Malformations in a Large, Multiethnic, Defined Population

Open access
Gabriel, Rodney A., Kim, Helen, Sidney, Stephen, McCulloch, Charles E., Singh, Vineeta, Johnston, S. Claiborne, Ko, Nerissa U., Achrol, Achal S., Zaroff, Jonathan G., Young, William L. · 2010 · Stroke

Abstract

Background and Purpose— To evaluate whether increased neuroimaging use is associated with increased brain arteriovenous malformation (BAVM) detection, we examined detection rates in the Kaiser Permanente Medical Care Program of northern California between 1995 and 2004. Methods— We reviewed medical records, radiology reports, and administrative databases to identify BAVMs, intracranial aneurysms (IAs: subarachnoid hemorrhage [SAH] and unruptured aneurysms), and other vascular malformations (OVMs: dural fistulas, cavernous malformations, Vein of Galen malformations, and venous malformations). Poisson regression (with robust standard errors) was used to test for trend. Random-effects meta-analysis generated a pooled measure of BAVM detection rate from 6 studies. Results— We identified 401 BAVMs (197 ruptured, 204 unruptured), 570 OVMs, and 2892 IAs (2079 SAHs and 813 unruptured IAs). Detection rates per 100 000 person-years were 1.4 (95% CI, 1.3 to 1.6) for BAVMs, 2.0 (95% CI, 1.8 to 2.3) for OVMs, and 10.3 (95% CI, 9.9 to 10.7) for IAs. Neuroimaging utilization increased 12% per year during the time period ( P <0.001). Overall, rates increased for IAs ( P <0.001), remained stable for OVMs ( P =0.858), and decreased for BAVMs ( P =0.001). Detection rates increased 15% per year for unruptured IAs ( P <0.001), with no change in SAHs ( P =0.903). However, rates decreased 7% per year for unruptured BAVMs ( P =0.016) and 3% per year for ruptured BAVMs ( P =0.005). Meta-analysis yielded a pooled BAVM detection rate of 1.3 (95% CI, 1.2 to 1.4) per 100 000 person-years, without heterogeneity between studies ( P =0.25). Conclusions— Rates for BAVMs, OVMs, and IAs in this large, multiethnic population were similar to those in other series. During 1995 to 2004, a period of increasing neuroimaging utilization, we did not observe an increased rate of detection of unruptured BAVMs, despite increased detection of unruptured IAs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/strokeaha.109.566018

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Gabriel, R. A., Kim, H., Sidney, S., McCulloch, C. E., Singh, V., Johnston, S. C., Ko, N. U., Achrol, A. S., Zaroff, J. G., & Young, W. L.
Venue
Stroke
Published
2010-01
Volume
41
Issue
1
Pages
21-26
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2013745378
Cited by
236
References
1
FWCI
4.88
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.