Fluid-Attenuated Inversion Recovery Evolution Within 12 Hours From Stroke Onset: A Reliable Tissue Clock?
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background and Purpose— It has recently been proposed that fluid-attenuated inversion recovery (FLAIR) imaging may serve as a surrogate marker for time of symptom onset after stroke. We assessed the hypothesis that FLAIR imaging could be used to decide if an MRI was performed within 4.5 hours from symptom onset or later. Methods— All consecutive patients with presumed stroke who underwent an MRI within 12 hours after known symptom onset were included regardless of stroke subtype and severity between May 2008 and May 2009. Blinded to time of symptom onset, 2 raters judged the visibility of lesions on FLAIR. Apparent diffusion coefficient values, lesion volume on diffusion-weighted imaging, and relative signal intensity of FLAIR lesions were determined. Results— In 94 consecutive patients with stroke, we found that median time from symptom onset for FLAIR-positive patients (189 minutes; interquartile range, 110 to 369 minutes) was significantly longer compared with FLAIR-negative patients (103 minutes; interquartile range, 75 to 183 minutes; P =0.011). Negative FLAIR had a sensitivity of 46% and a specificity of 79% for allocating patients to a time window of less than 4.5 hours. FLAIR positivity increased with diffusion-weighted imaging lesion volume ( P <0.001) but showed no correlation with apparent diffusion coefficient values ( P =0.795). There was no significant correlation between relative signal intensity and time from symptom onset (Spearman correlation coefficient −0.152, P =0.128). Conclusions— Based on our findings, we cannot recommend the use of FLAIR visibility as an estimate of time from symptom onset within the first 4.5 hours.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thrombolysis with Alteplase 3 to 4.5 Hours after Acute Ischemic Stroke
Hacke, W., Kaste, M., Bluhmki, E., Brozman, M., Dávalos, A., Guidetti, D., Larrue, V., Lees, K. R., Medeghri, Z., Machnig, T., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0804656 · Cited by 6,684
Feigin, V. L., Lawes, C. M., Bennett, D. A., Barker-Collo, S. L., & Parag, V. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70025-0 · Cited by 2,855
Cited by
Demaerschalk, B. M., Kleindorfer, D. O., Adeoye, O. M., Demchuk, A. M., Fugate, J. E., Grotta, J. C., Khalessi, A. A., Levy, E. I., Palesch, Y. Y., Prabhakaran, S., et al. (2016) · Stroke · doi:10.1161/str.0000000000000086 · Cited by 670
Thomalla, G., Cheng, B., Ebinger, M., Hao, Q., Tourdias, T., Wu, O., Kim, J. S., Breuer, L., Singer, O. C., Warach, S., et al. (2011) · The Lancet Neurology · doi:10.1016/s1474-4422(11)70192-2 · Cited by 602
Self-citationMachine Learning Approach to Identify Stroke Within 4.5 Hours
Lee, H., Lee, E.-J., Ham, S., Lee, H.-B., Lee, J. S., Kwon, S. U., Kim, J. S., Kim, N., & Kang, D.-W. (2020) · Stroke · doi:10.1161/strokeaha.119.027611 · Cited by 206
Artificial intelligence as an emerging technology in the current care of neurological disorders
Patel, U. K., Anwar, A., Saleem, S., Malik, P., Rasul, B., Patel, K., Yao, R., Seshadri, A., Yousufuddin, M., & Arumaithurai, K. (2021) · Journal of Neurology · doi:10.1007/s00415-019-09518-3 · Cited by 197
Silent cerebral events/lesions related to atrial fibrillation ablation: a clinical review
DENEKE, T., JAIS, P., SCAGLIONE, M., SCHMITT, R., DI BIASE, L., CHRISTOPOULOS, G., SCHADE, A., MÜGGE, A., BANSMANN, M., NENTWICH, K., et al. (2015) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12608 · Cited by 170
Merino, J. G., & Warach, S. (2010) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.129 · Cited by 152
Feng, J., Zhang, Q., Wu, F., Peng, J., Li, Z., & Chen, Z. (2023) · Journal of Medical Internet Research · doi:10.2196/44895 · Cited by 12
Metadata
- Authors
- Ebinger, M., Galinovic, I., Rozanski, M., Brunecker, P., Endres, M., & Fiebach, J. B.
- Venue
- Stroke
- Published
- 2010-02
- Volume
- 41
- Issue
- 2
- Pages
- 250-255
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2134605661
- Cited by
- 119
- References
- 2
- FWCI
- 6.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.