Monitoring Cerebral Blood Flow Pressure Autoregulation in Pediatric Patients During Cardiac Surgery
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background and Purpose— The limits of cerebral blood flow-pressure autoregulation have not been adequately defined for pediatric patients. Mean arterial blood pressure below these limits might contribute to brain injury during cardiac surgery. The purpose of this pilot study was to assess a novel method of determining the lower limits of pressure autoregulation in pediatric patients supported with cardiopulmonary bypass. Methods— A prospective, observational pilot study was conducted in children (n=54) undergoing cardiac surgery with cardiopulmonary bypass for correction of congenital heart defects. Cerebral oximetry index (COx) was calculated as a moving, linear correlation coefficient between slow waves of arterial blood pressure and cerebral oximetry measured with near-infrared spectroscopy. An autoregulation curve was constructed for each patient with averaged COx values sorted by arterial blood pressure. Results— Hypotension was associated with increased values of COx ( P <0.0001). For 77% of patients, an individual estimate of lower limits of pressure autoregulation could be determined using a threshold COx value of 0.4. The mean lower limits of pressure autoregulation for the cohort using this method was 42±7 mm Hg. Conclusions— This pilot study of COx monitoring in pediatric patients demonstrates an association between hypotension during cardiopulmonary bypass and impairment of autoregulation. The COx may be useful to identify arterial blood pressure-dependent limits of cerebral autoregulation during cardiopulmonary bypass. Larger trials with neurological outcomes are indicated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hosmer, D. W., & Lemeshow, S. (2000) · doi:10.1002/0471722146 · Cited by 20,302
Shillingford, A. J., Glanzman, M. M., Ittenbach, R. F., Clancy, R. R., Gaynor, J. W., & Wernovsky, G. (2008) · Pediatrics · doi:10.1542/peds.2007-1066 · Cited by 348 · cited 1×
“§Repair was categorized as: (1) isolated septal defects, atrial or ventricular; (2) shunting lesions, including tetralogy of Fallot, right ventricular outflow tract obstruction, and partial anomalous pulmonary venous return; (3) obstructing lesions, including right and left, subvalvular, supravalvular, and valvular st…”
Cited by
Fugate, J. E., & Rabinstein, A. A. (2015) · The Lancet Neurology · doi:10.1016/s1474-4422(15)00111-8 · Cited by 1,142
Smith, P. J., Blumenthal, J. A., Hoffman, B. M., Rivelli, S. K., Palmer, S. M., Davis, R. D., & Mathew, J. P. (2016) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201507-454oc · Cited by 46
Cerebral blood flow dynamics during cardiac surgery in infants
Leth-Olsen, M., Døhlen, G., Torp, H., & Nyrnes, S. A. (2025) · Pediatric Research · doi:10.1038/s41390-024-03161-z · Cited by 12
Metadata
- Authors
- Brady, K. M., Mytar, J. O., Lee, J. K., Cameron, D. E., Vricella, L. A., Thompson, W. R., Hogue, C. W., & Easley, R. B.
- Venue
- Stroke
- Published
- 2010-09
- Volume
- 41
- Issue
- 9
- Pages
- 1957-1962
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2120637542
- Cited by
- 193
- References
- 2
- FWCI
- 9.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.