New Generation of Flow Diverter (Surpass) for Unruptured Intracranial Aneurysms: A Prospective Single-Center Study in 37 Patients

De Vries, Joost, Boogaarts, Jeroen, Van Norden, Anouk, Wakhloo, Ajay K.·2013·Stroke

Abstract

Background and Purpose—: In patients harboring intracranial aneurysms, the major goal in treatment is to prevent bleeding. A new generation of an endoluminal device (Surpass Flow Diverter [Surpass]) was developed to reconstruct parent artery and occlude the aneurysm. We present our clinical and angiographic single-center experience. Methods—: Patients with a wide range of complex unruptured aneurysms were treated with the Surpass placed in the parent artery and bridging the aneurysm. Clinical and angiographic follow-up were performed at 6 months. Data were prospectively collected. Results—: Thirty seven patients (mean age, 56 years; range, 32–79), harboring 49 unruptured aneurysms were treated at our center. All except 1 patient were treated with a single device. Successful delivery of the device was achieved in all patients. All 35 nonbifurcation aneurysm necks were covered completely, whereas 14 bifurcation aneurysms were only partially covered. There was no major periprocedural morbidity or mortality. During follow-up, 4 patients (10.4%) experienced transient neurological deficit. One patient (3%) developed a minor stroke at 4-month follow-up with persistent neurological deficit. Twelve patients had neurological symptoms related to their aneurysm and 7 showed improvement of these symptoms during follow-up. At 6-month follow-up, 29 of 31 aneurysms studied that had complete neck coverage showed a complete occlusion (94%) including 1 case with a 95% to 100% occlusion, whereas 5 of the 10 bifurcation aneurysms were occluded. Conclusions—: Our study shows high safety and efficacy profile of a new generation endoluminal device in treatment of complex intracranial aneurysms. Long-term studies of treated bifurcation aneurysms are needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/strokeaha.111.000434

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 165

Metadata

Authors
De Vries, J., Boogaarts, J., Van Norden, A., & Wakhloo, A. K.
Venue
Stroke
Published
2013-06
Volume
44
Issue
6
Pages
1567-1577
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2117445677
Cited by
165
References
2
FWCI
11.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.