Occult Atrial Fibrillation in Cryptogenic Stroke: Detection by 7-Day Electrocardiogram Versus Implantable Cardiac Monitors
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Background and Purpose—: A significant number of patients with cryptogenic stroke suffer from intermittent atrial fibrillation (iAF) which was not detected during the standard diagnostic procedures. We investigated whether implantation of an insertable cardiac monitor (ICM) is feasible in patients with cryptogenic stroke, and compared the iAF detection rate of the ICM with 7-day Holter monitoring. Methods—: Sixty patients (median age 63; interquartile range, 48.5–72 years) with acute cryptogenic stroke were included. ICM was implanted 13 days (interquartile range; 10–65 days) after the qualifying event. Seven-day Holter was performed after the ICM was implanted. Results—: The iAF was detected by the ICM in 10 patients (17%; 95% CI, 7% to 26%). Only 1 patient (1.7%; 95% CI, 0% to 5%) had iAF during 7-day Holter monitoring as well ( P =0.0077). Episodes of iAF lasting 2 minutes or more were detected 64 (range, 1–556) days after implantation. There were no recurrent strokes during the observation period. The implantation procedure was well tolerated with no adverse events; the daily data transmission protocol was easy to handle by the patients. Conclusions—: ICM implantation for the detection of iAF during outpatient follow-up is feasible in patients with cryptogenic stroke. ICMs offer a much higher diagnostic yield than 7-day Holter monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adams, H. P., Bendixen, B. H., Kappelle, L. J., Biller, J., Love, B. B., Gordon, D. L., & Marsh, E. E. (1993) · Stroke · doi:10.1161/01.str.24.1.35 · Cited by 12,335 · cited 1×
“Patients with acute stroke classified as cryptogenic stroke according to the TOAST criteria, who were admitted to our stroke unit between November 2010 and May 2012, were included.(8) An intensive diagnostic work-up was performed to determine stroke pathogenesis: All patients had to have embolic stroke patterns on cer…”
MethodGlotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
Hindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422
Jabaudon, D., Sztajzel, J., Sievert, K., Landis, T., & Sztajzel, R. (2004) · Stroke · doi:10.1161/01.str.0000131269.69502.d9 · Cited by 414
Atrial fibrillation detected by mobile cardiac outpatient telemetry in cryptogenic TIA or stroke
Tayal, A. H., Tian, M., Kelly, K. M., Jones, S. C., Wright, D. G., Singh, D., Jarouse, J., Brillman, J., Murali, S., & Gupta, R. (2008) · Neurology · doi:10.1212/01.wnl.0000325059.86313.31 · Cited by 321
Comparison of continuous versus intermittent monitoring of atrial arrhythmias
Ziegler, P. D., Koehler, J. L., & Mehra, R. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.07.030 · Cited by 282 · cited 1×
“Especially, the low yield of a 1-time 24-hour Holter ECG in detecting iAF is well known.(2) Longer monitoring times improved the detection rate of iAF in patients with cryptogenic stroke.”
BackgroundRizos, T., Güntner, J., Jenetzky, E., Marquardt, L., Reichardt, C., Becker, R., Reinhardt, R., Hepp, T., Kirchhof, P., Aleynichenko, E., et al. (2012) · Stroke · doi:10.1161/strokeaha.112.654954 · Cited by 218
Stahrenberg, R., Weber-Krüger, M., Seegers, J., Edelmann, F., Lahno, R., Haase, B., Mende, M., Wohlfahrt, J., Kermer, P., Vollmann, D., et al. (2010) · Stroke · doi:10.1161/strokeaha.110.591958 · Cited by 213
Boriani, G., Botto, G. L., Padeletti, L., Santini, M., Capucci, A., Gulizia, M., Ricci, R., Biffi, M., De Santo, T., Corbucci, G., et al. (2011) · Stroke · doi:10.1161/strokeaha.110.609297 · Cited by 183
Ziegler, P. D., Glotzer, T. V., Daoud, E. G., Singer, D. E., Ezekowitz, M. D., Hoyt, R. H., Koehler, J. L., Coles, J., & Wyse, D. G. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2012.06.034 · Cited by 162 · cited 1×
“In a recently published large primary prevention trial, ICMs were implanted in patients with stroke risk factors but no thromboembolic event.(12) The authors were also unable to detect specific clinical factors predictive of the occurrence of iAF.”
Method
Cited by
Embolic strokes of undetermined source: the case for a new clinical construct
Hart, R. G., Diener, H.-C., Coutts, S. B., Easton, J. D., Granger, C. B., O'Donnell, M. J., Sacco, R. L., & Connolly, S. J. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70310-7 · Cited by 1,681
Sposato, L. A., Cipriano, L. E., Saposnik, G., Vargas, E. R., Riccio, P. M., & Hachinski, V. (2015) · The Lancet Neurology · doi:10.1016/s1474-4422(15)70027-x · Cited by 694
National trends in ambulatory oral anticoagulant use
Barnes, G. D., Lucas, E., Alexander, G. C., & Goldberger, Z. D. (2015) · The American Journal of Medicine · doi:10.1016/j.amjmed.2015.05.044 · Cited by 598
Barrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.10.003 · Cited by 498
Grond, M., Jauss, M., Hamann, G., Stark, E., Veltkamp, R., Nabavi, D., Horn, M., Weimar, C., Köhrmann, M., Wachter, R., et al. (2013) · Stroke · doi:10.1161/strokeaha.113.001884 · Cited by 229
Metadata
- Authors
- Ritter, M. A., Kochhäuser, S., Duning, T., Reinke, F., Pott, C., Dechering, D. G., Eckardt, L., & Ringelstein, E. B.
- Venue
- Stroke
- Published
- 2013-05
- Volume
- 44
- Issue
- 5
- Pages
- 1449-1452
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2049420962
- Cited by
- 180
- References
- 12
- FWCI
- 16.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Occult Atrial Fibrillation in Cryptogenic Stroke: Detection by 7-Day Electrocardiogram Versus Implantable Cardiac Monitors. https://app.cochat.ai/papers/10.1161/strokeaha.111.676189
- The paper
- Ritter, M. A., Kochhäuser, S., Duning, T., Reinke, F., Pott, C., Dechering, D. G., Eckardt, L., & Ringelstein, E. B. (2013). Occult Atrial Fibrillation in Cryptogenic Stroke: Detection by 7-Day Electrocardiogram Versus Implantable Cardiac Monitors. Stroke. https://doi.org/10.1161/strokeaha.111.676189
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.