Hospital Costs Associated With Atrial Fibrillation for Patients With Ischemic Stroke Aged 18–64 Years in the United States
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background and Purpose—: Hospital costs associated with atrial fibrillation (AFib) among patients with stroke have not been well-studied, especially among people aged <65 years. We estimated the AFib-associated hospital costs in US patients aged 18 to 64 years. Methods—: We identified hospital admissions with a primary diagnosis of ischemic stroke from the 2010 to 2012 MarketScan Commercial Claims and Encounters inpatient data sets, excluding those with capitated health insurance plans, aged <18 or >64 years, missing geographic region, hospital costs below the 1st or above 99th percentile, and having carotid intervention (n=40 082). We searched the data for AFib and analyzed the costs for nonrepeat and repeat stroke admissions separately. We estimated the AFib-associated costs using multivariate regression models controlling for age, sex, geographic region, and Charlson comorbidity index. Results—: Of the 33 500 nonrepeat stroke admissions, 2407 (7.2%) had AFib. Admissions with AFib cost $4991 more than those without AFib ($23 770 versus $18 779). For the 6582 repeat stroke admissions, 397 (6.0%) had AFib. The costs were $3260 more for those with AFib than those without ($24 119 versus $20 929). After controlling for potential confounders, AFib-associated costs for nonrepeat stroke admissions were $4905, representing 20.6% of the total costs for the admissions. Both the hospital costs and the AFib-associated costs were associated with age, but not with sex. AFib-associated costs for repeat stroke admissions were not significantly higher than for non-AFib patients, except for those aged 55 to 64 years ($3537). Conclusions—: AFib increased the hospital cost of ischemic stroke substantially. Further investigation on AFib-associated costs for repeat stroke admissions is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heidenreich, P. A., Trogdon, J. G., Khavjou, O. A., Butler, J., Dracup, K., Ezekowitz, M. D., Finkelstein, E. A., Hong, Y., Johnston, S. C., Khera, A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31820a55f5 · Cited by 3,208
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Atrial fibrillation in patients with cryptogenic stroke
Gladstone, D. J., Spring, M., Dorian, P., Panzov, V., Thorpe, K. E., Hall, J., Vaid, H., O'Donnell, M., Laupacis, A., Côté, R., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1311376 · Cited by 1,276
Marini, C., De Santis, F., Sacco, S., Russo, T., Olivieri, L., Totaro, R., & Carolei, A. (2005) · Stroke · doi:10.1161/01.str.0000166053.83476.4a · Cited by 949
Maternal mortality in the United States
Lang, C. T., & King, J. C. (2008) · Best Practice & Research Clinical Obstetrics & Gynaecology · doi:10.1016/j.bpobgyn.2007.10.004 · Cited by 404
Cited by
Heart Disease and Stroke Statistics—2017 Update: A Report From the American Heart Association
Benjamin, E. J., Blaha, M. J., Chiuve, S. E., Cushman, M., Das, S. R., Deo, R., de Ferranti, S. D., Floyd, J., Fornage, M., Gillespie, C., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000485 · Cited by 12,591
Heart disease and stroke statistics-2018 update: a report from the american heart association
Benjamin, E. J., Virani, S. S., Callaway, C. W., Chamberlain, A. M., Chang, A. R., Cheng, S., Chiuve, S. E., Cushman, M., Delling, F. N., Deo, R., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000558 · Cited by 7,146
Zhao, L., Dai, Q., Chen, X., Li, S., Shi, R., Yu, S., Yang, F., Xiong, Y., & Zhang, R. (2016) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2015.11.012 · Cited by 46
Metadata
- Authors
- Wang, G., Joo, H., Tong, X., & George, M. G.
- Venue
- Stroke
- Published
- 2015-05
- Volume
- 46
- Issue
- 5
- Pages
- 1314-1320
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2081439943
- Cited by
- 41
- References
- 5
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.