The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effects of hemolysis interference on routine biochemistry parameters
Open accessAbstract
INTRODUCTION: Hemolysis is still the most common reason for rejecting samples, while reobtaining a new sample is an important problem. The aim of this study was to investigate the effects of hemolysis in different hemolysis levels for mostly used biochemical parameters to prevent unnecessary rejections. MATERIALS AND METHODS: Sixteen healthy volunteers were enrolled in the study. Four hemolysis levels were constituted according to hemoglobin concentrations and they were divided into five groups: Group I: 0-0.10 g/L, Group II:0.10-0.50 g/L, Group III: 0.51-1.00 g/L, Group IV: 1.01-2.50 g/L, Group V: 2.51-4.50 g/L. Lysis was achieved by mechanical trauma. RESULTS: Hemolysis interference affected lactate dehydrogenase (LD) and aspartate aminotransferase (AST) almost at undetectable hemolysis by visual inspection (plasma hemoglobin < 0.5 g/L). Clinically meaningful variations of potassium and total bilirubin were observed in moderately hemolyzed samples (hemoglobin > 1 g/L). Alanine aminotransferase (ALT), cholesterol, gamma glutamyltransferase (GGT), and inorganic phosphate (P) concentrations were not interfered up to severely hemolyzed levels (hemoglobin: 2.5-4.5 g/L). Albumin, alkaline phosphatase (ALP), amylase, chloride, HDL-cholesterol, creatine kinase (CK), glucose, magnesium, total protein, triglycerides, unsaturated iron binding capacity (UIBC) and uric acid differences were statistically significant, but remained within the CLIA limits. CONCLUSION: To avoid preanalytical visual inspection for hemolysis detection, improper sample rejection, and/or rerun because of hemolysis, it is recommended in this study that, routine determination of plasma or serum free hemoglobin concentrations is important. For the analytes interfered with hemolysis, new samples have to be requested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bonini, P., Plebani, M., Ceriotti, F., & Rubboli, F. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.691 · Cited by 850
Cited by
Cao, Z., Jia, Y., & Zhu, B. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20081820 · Cited by 398
Iwamoto, N., Butler, D. C. D., Svrzikapa, N., Mohapatra, S., Zlatev, I., Sah, D. W. Y., Meena, Standley, S. M., Lu, G., Apponi, L. H., et al. (2017) · Nature Biotechnology · doi:10.1038/nbt.3948 · Cited by 377
Phlebotomy, a bridge between laboratory and patient
Ialongo, C., & Bernardini, S. (2016) · Biochemia Medica · doi:10.11613/bm.2016.002 · Cited by 97
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2012) · Biochemia Medica · doi:10.11613/bm.2012.036 · Cited by 66
Blood Glucose Determination: Effect of Tube Additives
(2018) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2017.12.003 · Cited by 28
Measuring haemolysis in cattle serum by direct UV–VIS and RGB digital image-based methods
Larrán, B., López-Alonso, M., Miranda, M., Pereira, V., Rigueira, L., Suárez, M. L., & Herrero-Latorre, C. (2022) · Scientific Reports · doi:10.1038/s41598-022-17842-4 · Cited by 7
Metadata
- Authors
- Koseoglu, M., Hur, A., Atay, A., & Cuhadar, S.
- Venue
- Biochemia Medica
- Published
- 2011
- Volume
- 21
- Issue
- 1
- Pages
- 79-85
- ISSN
- 1330-0962 (ISSN-L)
- 1846-7482
- OpenAlex
- W2137896147
- Cited by
- 195
- References
- 1
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.