Deconvolution of Event-Related fMRI Responses in Fast-Rate Experimental Designs: Tracking Amplitude Variations
The DOI matches its Crossref record.
Abstract
Recent developments towards event-related functional magnetic resonance imaging has greatly extended the range of experimental designs. If the events occur in rapid succession, the corresponding time-locked responses overlap significantly and need to be deconvolved in order to separate the contributions of different events. Here we present a deconvolution approach, which is especially aimed at the analysis of fMRI data where sequence- or context-related responses are expected. For this purpose, we make the assumption of a hemodynamic response function (HDR) with constant yet not predefined shape but with possibly variable amplitudes. This approach reduces the number of variables to be estimated but still keeps the solutions flexible with respect to the shape. Consequently, statistical efficiency is improved. Temporal variations of the HDR strength are directly indicated by the amplitudes derived by the algorithm. Both the estimation efficiency and statistical inference are further supported by an improved estimation of the noise covariance. Using synthesized data sets, both differently shaped HDRs and varying amplitude factors were correctly identified. The gain in statistical sensitivity led to improved ratios of false- and true-positive detection rates for synthetic activations in these data. In an event-related fMRI experiment with a human subject, different HDR amplitudes could be derived corresponding to stimulation at different visual stimulus contrasts. Finally, in a visual spatial attention experiment we obtained different fMRI response amplitudes depending on the sequences of attention conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Study design in fMRI: Basic principles
Amaro, E., & Barker, G. J. (2006) · Brain and Cognition · doi:10.1016/j.bandc.2005.11.009 · Cited by 517
Absolute Coding of Stimulus Novelty in the Human Substantia Nigra/VTA
Bunzeck, N., & Düzel, E. (2006) · Neuron · doi:10.1016/j.neuron.2006.06.021 · Cited by 503
Optimization of experimental design in fMRI: a general framework using a genetic algorithm
Wager, T. D., & Nichols, T. E. (2003) · NeuroImage · doi:10.1016/s1053-8119(02)00046-0 · Cited by 458
“If X consists of a deconvolution matrix (Glover, 1999; Hinrichs et al., 2000; Menon et al., 1998), and C is the identity matrix, Eq.”
MethodRenewal of the Neurophysiology of Language: Functional Neuroimaging
Démonet, J.-F., Thierry, G., & Cardebat, D. (2005) · Physiological Reviews · doi:10.1152/physrev.00049.2003 · Cited by 418
Efficient Design of Event-Related fMRI Experiments Using M-Sequences
Buračas, G. T., & Boynton, G. M. (2002) · NeuroImage · doi:10.1006/nimg.2002.1116 · Cited by 271
Metadata
- Authors
- Hinrichs, H., Scholz, M., Tempelmann, C., Woldorff, M. G., Dale, A. M., & Heinze, H.-J.
- Venue
- Journal of Cognitive Neuroscience
- Publisher
- MIT Press - Journals
- Published
- 2000-11-01
- Volume
- 12
- Issue
- Supplement 2
- Pages
- 76-89
- ISSN
- 0898-929X (ISSN-L)
- 1530-8898
- OpenAlex
- W2104925726
- Cited by
- 117
- References
- 0
- FWCI
- 1.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deconvolution of Event-Related fMRI Responses in Fast-Rate Experimental Designs: Tracking Amplitude Variations. https://app.cochat.ai/papers/10.1162/089892900564082
- The paper
- Hinrichs, H., Scholz, M., Tempelmann, C., Woldorff, M. G., Dale, A. M., & Heinze, H.-J. (2000). Deconvolution of Event-Related fMRI Responses in Fast-Rate Experimental Designs: Tracking Amplitude Variations. Journal of Cognitive Neuroscience. https://doi.org/10.1162/089892900564082
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.