The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Modeling of Tool-Tissue Interactions for Computer-Based Surgical Simulation: A Literature Review
Open accessAbstract
Surgical simulators present a safe and potentially effective method for surgical training, and can also be used in robot-assisted surgery for pre- and intra-operative planning. Accurate modeling of the interaction between surgical instruments and organs has been recognized as a key requirement in the development of high-fidelity surgical simulators. Researchers have attempted to model tool-tissue interactions in a wide variety of ways, which can be broadly classified as (1) linear elasticity-based, (2) nonlinear (hyperelastic) elasticity-based finite element (FE) methods, and (3) other techniques not based on FE methods or continuum mechanics. Realistic modeling of organ deformation requires populating the model with real tissue data (which are difficult to acquire in vivo) and simulating organ response in real time (which is computationally expensive). Further, it is challenging to account for connective tissue supporting the organ, friction, and topological changes resulting from tool-tissue interactions during invasive surgical procedures. Overcoming such obstacles will not only help us to model tool-tissue interactions in real time, but also enable realistic force feedback to the user during surgical simulation. This review paper classifies the existing research on tool-tissue interactions for surgical simulators specifically based on the modeling techniques employed and the kind of surgical operation being simulated, in order to inform and motivate future research on improved tool-tissue interaction models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A three-dimensional constitutive model for the large stretch behavior of rubber elastic materials
Arruda, E. M., & Boyce, M. C. (1993) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(93)90013-6 · Cited by 3,239 · cited 2×
“The Arruda-Boyce model (Arruda & Boyce, 1993), which is based on statistical mechanics and normally used to model rubber, has been used to simulate palpation of breast tissues in Y. Liu, Kerdok, and Howe (2004).”
MethodBiomechanics: Mechanical Properties of Living Tissues, 2nd ed.
Fung, Y. C., & Cowin, S. C. (1994) · Journal of Applied Mechanics · doi:10.1115/1.2901550 · Cited by 745
Realistic force feedback for virtual reality based diagnostic surgery simulators
Vuskovic, V., Kauer, M., Szekely, G., & Reidy, M. (2002) · Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065) · doi:10.1109/robot.2000.844824 · Cited by 71
Cited by
Mechanics of Flexible Needles Robotically Steered through Soft Tissue
Misra, S., Reed, K. B., Schafer, B. W., Ramesh, K. T., & Okamura, A. M. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910369714 · Cited by 314
Self-citationBenson, N. C., Butt, O. H., Brainard, D. H., & Aguirre, G. K. (2014) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1003538 · Cited by 222
Metadata
- Authors
- Misra, S., Ramesh, K. T., & Okamura, A. M.
- Venue
- Presence: Teleoperators and Virtual Environments
- Publisher
- MIT Press - Journals
- Published
- 2008-10-01
- Volume
- 17
- Issue
- 5
- Pages
- 463-491
- ISSN
- 1054-7460 (ISSN-L)
- OpenAlex
- W2121272278
- Cited by
- 219
- References
- 3
- FWCI
- 11.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modeling of Tool-Tissue Interactions for Computer-Based Surgical Simulation: A Literature Review. https://app.cochat.ai/papers/10.1162/pres.17.5.463
- The paper
- Misra, S., Ramesh, K. T., & Okamura, A. M. (2008). Modeling of Tool-Tissue Interactions for Computer-Based Surgical Simulation: A Literature Review. Presence: Teleoperators and Virtual Environments. https://doi.org/10.1162/pres.17.5.463
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.