The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Mechanics of Flexible Needles Robotically Steered through Soft Tissue
Open accessAbstract
The tip asymmetry of a bevel-tip needle results in the needle naturally bending when it is inserted into soft tissue. This enables robotic needle steering, which can be used in medical procedures to reach subsurface targets inaccessible by straight-line trajectories. However, accurate path planning and control of needle steering require models of needle-tissue interaction. Previous kinematic models required empirical observations of each needle and tissue combination in order to fit model parameters. This study describes a mechanics-based model of robotic needle steering, which can be used to predict needle behavior and optimize system design based on fundamental mechanical and geometrical properties of the needle and tissue. We first present an analytical model for the loads developed at the tip, based on the geometry of the bevel edge and material properties of soft-tissue simulants (gels). We then present a mechanics-based model that calculates the deflection of a bevel-tipped needle inserted through a soft elastic medium. The model design is guided by microscopic observations of needle-gel interactions. The energy-based formulation incorporates tissue-specific parameters, and the geometry and material properties of the needle. Simulation results follow similar trends (deflection and radius of curvature) to those observed in experimental studies of robotic needle insertion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Timoshenko, S. P. (1936) · UCLA Biblioteca de Ingenieria Civil · Cited by 7,592
Fracture Mechanics: Fundamentals and Applications
Anderson, T. L. (2017) · CRC Press eBooks · doi:10.1201/9781315370293 · Cited by 4,737
Theory of Elastic Stability: Analysis and Sensitivity
Godoy, L. A. (2024) · CRC Press eBooks · doi:10.1201/9781003578659 · Cited by 2,214
Fracture Mechanics: Fundamentals and Applications
Janßen, M., Zuidema, J., & Wanhill, R. J. H. (2004) · Cited by 1,723
An Introduction to Continuum Mechanics
Gurtin, M. E., & Drugan, W. J. (1984) · Journal of Applied Mechanics · doi:10.1115/1.3167763 · Cited by 1,704
Force Modeling for Needle Insertion Into Soft Tissue
Okamura, A. M., Simone, C., & O'Leary, M. D. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.831542 · Cited by 830
Self-citationNeedle insertion into soft tissue: A survey
Abolhassani, N., Patel, R., & Moallem, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.07.003 · Cited by 704
Nonholonomic Modeling of Needle Steering
Webster, R. J., Kim, J. S., Cowan, N. J., Chirikjian, G. S., & Okamura, A. M. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065388 · Cited by 633
Self-citationNonholonomic Modeling of Needle Steering
Webster, R. J., Cowan, N. J., Chirikjian, G., & Okamura, A. M. (2006) · Springer Tracts in Advanced Robotics · doi:10.1007/11552246_4 · Cited by 527
Self-citation
Cited by
Alambeigi, F., Aghajani Pedram, S., Speyer, J. L., Rosen, J., Iordachita, I., Taylor, R. H., & Armand, M. (2020) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2946726 · Cited by 48
Metadata
- Authors
- Misra, S., Reed, K. B., Schafer, B. W., Ramesh, K. T., & Okamura, A. M.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2010-06-03
- Volume
- 29
- Issue
- 13
- Pages
- 1640-1660
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2128339709
- Cited by
- 314
- References
- 16
- FWCI
- 10.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanics of Flexible Needles Robotically Steered through Soft Tissue. https://app.cochat.ai/papers/10.1177/0278364910369714
- The paper
- Misra, S., Reed, K. B., Schafer, B. W., Ramesh, K. T., & Okamura, A. M. (2010). Mechanics of Flexible Needles Robotically Steered through Soft Tissue. The International Journal of Robotics Research. https://doi.org/10.1177/0278364910369714
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.