Intention-based walking support for paraplegia patients with Robot Suit HAL
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper proposes an algorithm to estimate human intentions related to walking in order to comfortably and safely support a paraplegia patient's walk. Robot Suit HAL (Hybrid Assistive Limb) has been developed for enhancement of a healthy person's activities and for support of a physically challenged person's daily life. The assisting method based on bioelectrical signals such as myoelectricity successfully supports a healthy person's walking. These bioelectrical signals, however, cannot be measured properly from a paraplegia patient. Therefore another interface that can estimate a patient's intentions without any manual controller is desired for robot control since a manual controller deprives a patient of his/her hand freedom. Estimation of a patient's intentions contributes to providing not only comfortable support but also safe support, because any inconformity between the robot suit motion and the patient motion results in his/her stumbling or falling. The proposed algorithm estimates a patient's intentions from a floor reaction force (FRF) reflecting a patient's weight shift during walking and standing. The effectiveness of this algorithm is investigated through experiments on a paraplegia patient who has a sensory paralysis on both legs, especially his left leg. We show that HAL supports the patient's walk properly, estimating his intentions based on the FRF, while he keeps his own balance by himself.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“To date, trajectory tracking control is primarily used in LEEs for early stage rehabilitation when patients have very weak muscle strength [58], [59].”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [59]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hybrid Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Steger, R., & Huang, L. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065505 · Cited by 382 · cited 1×
“Keywords: Robot suit; paraplegia; walking support; intention estimation; floor reaction force.”
BackgroundPower assist method based on Phase Sequence and muscle force condition for HAL
Kawamoto, H., & Sankai, Y. (2005) · Advanced Robotics · doi:10.1163/1568553054455103 · Cited by 381 · cited 1×
“Keywords: Robot suit; paraplegia; walking support; intention estimation; floor reaction force.”
BackgroundSelf-citationPower Assist System HAL-3 for Gait Disorder Person
Kawamoto, H., & Sankai, Y. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-45491-8_43 · Cited by 346 · cited 1×
“Keywords: Robot suit; paraplegia; walking support; intention estimation; floor reaction force.”
BackgroundSelf-citationLee, S., & Sankai, Y. (2003) · IEEE/RSJ International Conference on Intelligent Robots and System · doi:10.1109/irds.2002.1043967 · Cited by 291 · cited 1×
“Keywords: Robot suit; paraplegia; walking support; intention estimation; floor reaction force.”
BackgroundSelf-citationSato, M., Ikeuchi, H., Katoh, R., & Yamashita, T. (1993) · TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C · doi:10.1299/kikaic.59.3101 · Cited by 3
Research works printed but not linked: 7
- Junpei Okamura, Hiroshi Tanaka and Yoshiyuki Sankai, EMG-based Prototype Powered Assistive System for Walking Aid, in Proc. of Asian Symposium on Industrial Automation and Robotics (ASIAR'99) , Bangkok, pp.229-234 (1999).
- Takao Nakai, Suwoong Lee, Hiroaki Kawamoto and Yoshiyuki Sankai, Development of Powered Assistive Leg for Walking Aid using EMG and Linux, in Proc. of Asian Symposium on Industrial Automation and Robotics (ASIAR'01) , Bangkok, pp.295-299 (2001).
- Jerry E. Pratt, Benjamin T. Krupp, Christopher J. Morse and Steven H. Collins, The RoboKnee: An Exoskeleton for Enhancing Strength and Endurance During Walking, in Proc. of the 2004 IEEE International Conference on Robotics and Automation (ICRA '04) , New Orleans, pp.2430-2435 (2004).
- Takahiko Nakamura, Kazunari Saito and Kazuhiro Kosuge, Control of Wearable Walking Support System Based on Human-Model and GRF, Proc. of the 2005 IEEE International Conference on Robotics and Automation (ICRA '05) , Barcelona, pp. 4405-4410 (2005).
- Ryan Steger, Sung Hoon Kim and H. Kazerooni, Control Scheme and Networked Control Architecture for the Berkeley Lower Extremity Exoskeleton (BLEEX), in Proc. of the 2006 IEEE International Conference on Robotics and Automation (ICRA '06) , Orlando, Florida, pp. 3469-3476 (2006).
- H. Ikeuchi, K. Shinkoda, R. Katoh, M.Sato, T. Yamashita, Analysis of Human Transient Walking by Wavelet Transform, Proc. of The Third International Symposium on Artificial Life and Robotics , Beppu, Japan, pp.695-698 (1998).
- Suzuki K., Kawamura Y., Hayashi T., Sakurai T., Hasegawa Y. and Sankai Y., IntentionBased Walking Support for Paraplegia Patient, Proc. of the 2005 IEEE International Conference on Systems, Man and Cybernetics (SMC2005) , Hawaii, pp.2707-2713 (2005).
Cited by
Items 201–300 of 480
Power assistance for human elbow motion support using minimal EMG signals with admittance control
Zhu, C., Shimazu, S., Yoshioka, M., & Nishikawa, T. (2011) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2011.5985670 · Cited by 15
Gait modification for improving walking stability of exoskeleton assisted paraplegic patient
Li, M., Aoyama, T., & Hasegawa, Y. (2020) · ROBOMECH Journal · doi:10.1186/s40648-020-00169-y · Cited by 15
“In [10], HAL estimates the leg swing speed according to the walking velocity for restoring the gait of spinal cord injury patients.”
BackgroundSelf-citationAssistance of a Person with Muscular Weakness Using a Joint-Torque-Assisting Exoskeletal Robot
Choi, H. (2021) · Applied Sciences · doi:10.3390/app11073114 · Cited by 15
“There are cases where position tracking control is used in robots for people with partial impairment in walking ability, such as hemiplegic or stroke patients [17].”
BackgroundHasan, S., & Dhingra, A. K. (2021) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1177/09596518211009032 · Cited by 15
Concept proposal for a detachable exoskeleton-wheelchair to improve mobility and health
Borisoff, J., Mattie, J., & Rafer, V. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650396 · Cited by 15
Design and Kinematic Analysis of a Novel Metamorphic Mechanism for Lower Limb Rehabilitation
Zhang, W., Zhang, S., Ceccarelli, M., & Shi, D. (2015) · Mechanisms and machine science · doi:10.1007/978-3-319-23327-7_47 · Cited by 15
Takahashi, K., Mizukami, M., Watanabe, H., Kuroda, M. M., Shimizu, Y., Nakajima, T., Mutsuzaki, H., Kamada, H., Tokeji, K., Hada, Y., et al. (2023) · Frontiers in Neurology · doi:10.3389/fneur.2023.1255620 · Cited by 14
“In addition, the power unit amplifies the user’s joint torque, estimated from the user’s BES to generate power-assisted torque, and the HAL facilitates muscle activity and exercise by providing motion support based on voluntary movement and walking ability (7).”
BackgroundMethodInfluentialSelf-citationA soft exoskeleton suit to reduce muscle fatigue with pneumatic artificial muscles
Kosuke, T., Ohno, A., Fukuda, Y., Ogawa, K., Tsuji, T., & Kurita, Y. (2018) · Augmented Human International Conference · doi:10.1145/3174910.3174933 · Cited by 14
“Active actuators have many advantages, such as strong assist power and fine control[6][4][2].”
BackgroundJung, J.-Y., Park, H., Yang, H.-D., & Chae, M.-G. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650351 · Cited by 14
“HAL[1,2], ReWalk, and eLegs[3] are well–known, commercialized or nearly commercialized, exoskeleton-type robots.”
BackgroundPreliminary study of online gait recognizer for lower limb exoskeletons
Jang, J., Kim, K., Lee, J., Lim, B., Cho, J.-K., & Shim, Y. (2017) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2017.8206473 · Cited by 15
“INTRODUCTION In recent years, many lower limb exoskeletons have been developed to aid the ambulation of patients or disabled people [1]–[4].”
BackgroundContinuous Description of Human 3D Motion Intent Through Switching Mechanism
Huang, Y., Song, R., Argha, A., Savkin, A. V., Celler, B. G., & Su, S. W. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2949203 · Cited by 15
“This can be explained as healthy participants can voluntarily adjust their muscle activation and force when external assistance are provided [38].”
BackgroundMiura, K., Tsuda, E., Kogawa, M., Ishiyama, H., Maeda, K., Kuzuhara, K., Ito, I., Masuno, N., Urita, K., Saito, Y., et al. (2021) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2021.04.038 · Cited by 15
Walking assist device using Control Moment Gyroscopes
Matsuzaki, R., & Fujimoto, Y. (2013) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2013.6700220 · Cited by 14
Gait motion for naturally curving variously shaped corners
Akiyama, Y., Okamoto, S., Toda, H., Ogura, T., & Yamada, Y. (2017) · Advanced Robotics · doi:10.1080/01691864.2017.1396251 · Cited by 14
“The use of physical assistant robots has started spreading in society because such robots can be used not only for the rehabilitation on the treadmill [1] but also for gait assistance of the elderly in daily living [2,3].”
BackgroundShingu, M., Eguchi, K., & Sankai, Y. (2009) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2009.5420698 · Cited by 13
“By using HAL-5s, our research group has been developing control algorithm for physically challenged people, who have various types of impairments caused stroke, spinal cord injury, amyotrophic lateral sclerosis [ 7 ], [10].”
MethodSelf-citationArazpour, M., Samadian, M. M., Ebrahimzadeh, K., Bani, M. A., & Hutchins, S. W. (2016) · Spinal Cord · doi:10.1038/sc.2015.238 · Cited by 13
Multi-channel Fusion Based Adaptive Gait Trajectory Generation Using Wearable Sensors
Mazumder, O., Kundu, A. S., Lenka, P., & Bhaumik, S. (2016) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-016-0436-y · Cited by 17
“Gait trajectory generation for these devices requires integration of proper sensor technology, actuation mechanism, adaptive algorithm and proper control techniques [7, 8].”
MethodProbabilistic Sensitivity Amplification Control for Lower Extremity Exoskeleton
Wang, L., Du, Z., Dong, W., Shen, Y., & Zhao, G. (2018) · Applied Sciences · doi:10.3390/app8040525 · Cited by 13
“The problem of time-delay effect may be solved by the cognitive-based sensors [13,14], since the human intention can be acquired before the movement primitives.”
BackgroundYatsugi, A., Morishita, T., Fukuda, H., Kotani, N., Yagi, K., Abe, H., Shiota, E., & Inoue, T. (2018) · Applied Bionics and Biomechanics · doi:10.1155/2018/7435746 · Cited by 13
HIP-KNEE control for gait assistance with Powered Knee Orthosis
Lai, W.-Y., Ma, H., Liao, W., Fong, D. T.-P., & Chan, K. (2013) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2013.6739554 · Cited by 13
“2) HIP-KNEE control with footswitch: After sensor fusion with footswitch, results in Fig.”
MethodINS/EKF-based stride length, height and direction intent detection for walking assistance robots
Brescianini, D., Jung, J.-Y., Jang, I.-H., Park, H. S., & Riener, R. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975363 · Cited by 13
Human hip joint center analysis for biomechanical design of a hip joint exoskeleton
Yang, W., Yang, C.-J., & Xu, T. (2016) · Frontiers of Information Technology & Electronic Engineering · doi:10.1631/fitee.1500286 · Cited by 13
“…on treadmills (Lopes (Veneman et al., 2006) and Lokomat (Hidler et al., 2009)), wearable exoskeletons for paraplegic daily walking (HAL (Suzuki et al., 2007), Indego (Farris et al., 2011), and Rewalk (Esquenazi et al., 2012)), and upper arm exoskeletons for upper body rehabilitation…”
BackgroundLee, J., Kim, M.-K., & Kim, K. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2723609 · Cited by 13
A wearable projector-based gait assistance system and its application for elderly people
Murata, S., Suzuki, M., & Fujinami, K. (2013) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/2493432.2493472 · Cited by 13
“A robotic suit that supports the human leg with actuators has also been developed for gait assistance [29].”
MethodPerformance evaluations of hand and forearm support system
Hasegawa, Y., Watanabe, K., & Sankai, Y. (2010) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2010.5650355 · Cited by 12
“That is why a lot of exoskeleton systems are developed to support a healthy person [2], [3] and a physically challenged person [4], [5].”
BackgroundSelf-citationA Composite Robust Position Control Design for an Actuated Knee Rehabilitation Exoskeleton
Jenhani, S., & Gritli, H. (2023) · International Multi-Conference on Systems, Signals & Devices (SSD) · doi:10.1109/ssd58187.2023.10411251 · Cited by 12
“Then, this control has been connected to the balance of coriolis, friction, or gravity forces [33]–[37] to ensure gait rehabilitation, hold the body steady at the zero-moment position, and regulate the trajectory of the leg.”
BackgroundStudy on the control algorithm for lower limb exoskeleton based on ADAMS/Simulink co-simulation
Wu, H., Jia, T., Li, N., Wu, J., & Yan, L. (2017) · Journal of Vibroengineering · doi:10.21595/jve.2017.17303 · Cited by 12
“The Hybrid Assistive Limb (HAL) [8] developed in Tsukuba University of Japan is controlled by two control methods: CAC and CVC [9-11].”
MethodCPG Control for Harmonic Motion of Assistive Robot With Human Motor Control Identification
Zhao, J.-X., & Iwasaki, T. (2020) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2019.2910160 · Cited by 12
“A similar approach is used in robot suit hybrid assistive limb (HAL) [2], where the reference gait pattern is generated offline, the human-intended walking phase is estimated in real time to generate a command signal, and then, a PD controller achieves the regulation.”
MethodEnergy Shaping Control with Virtual Spring and Damper for Powered Exoskeletons
Lin, J., Divekar, N., Lv, G., & Gregg, R. D. (2019) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc40024.2019.9029624 · Cited by 12
“Most exoskeletons use trajectory-based control methods, for instance, the robot suit Hybrid Assistive Limb [1], ReWalk [2], Ekso Bionics [3], and the bilateral Wandercraft [4].”
MethodDesign and Evaluation of the Sit-to-Stand Movement Assistive Device for Elderly
Xu, Y., Zhang, B., Li, Y., Guo, R., Cao, P., Zhu, X., & Zhu, S. (2024) · Actuators · doi:10.3390/act13030102 · Cited by 11
“The HAL system has three motion joints—the ankle, the knee, and the hip joint—and is equipped with an electromyography (EMG) signal sensor that can predict the user’s motion intentions based on EMG signals [11].”
BackgroundA Realistic Model Reference Computed Torque Control Strategy for Human Lower Limb Exoskeletons
Hasan, S. (2024) · Actuators · doi:10.3390/act13110445 · Cited by 11
“[21] 12.”
Zhang, Q., Tu, X., Si, J., Lewek, M. D., & Huang, H. (2023) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros55552.2023.10341440 · Cited by 11
“…studies have addressed gait symmetry improvement by using hip exoskeletons and three main approaches, including joint trajectory-tracking control [14], [15], finite-state-machine (FSM)-based assistive control [16], [17], and adaptive frequency oscillators (AFO)-based assistive control [18]–[21].”
BackgroundImproving Spasticity by Using Botulin Toxin: An Overview Focusing on Combined Approaches
Raciti, L., Raciti, G., Ammendolia, A., Alessandro de, S. I. R. E., Onesta, M. P., & Calabrò, R. S. (2024) · Brain Sciences · doi:10.3390/brainsci14070631 · Cited by 11
“…on the severity of hemiplegia/hemiparesis, we could choose the kind of functional trial using exoskeletons (for severe hemiplegia: Lokomat [73], BLEEX [74], HAL [75], and LOPES [76]) or end-effectors (for mild to moderate motor impairment: gait-trainer, G-EOSystem, and haptic walker [57,58,77–81]).”
MethodTowards total energy shaping control of lower-limb exoskeletons
Lv, G., & Gregg, R. D. (2017) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2017.7963706 · Cited by 11
“The Hybrid Assistive Limb, designed for both augmenting healthy people’s joint power and assisting people with gait disorders, tracks the pre-defined reference joint patterns based on the subject’s intention during locomotion [4].”
Using Footsteps to Estimate Changes in the Desired Gait Speed of an Exoskeleton User
Karulkar, R. M., & Wensing, P. M. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3096163 · Cited by 11
“while walking using a lower-extremity exoskeleton [12].”
Lau, J. C. L., & Mombaur, K. (2022) · Frontiers in Robotics and AI · doi:10.3389/frobt.2021.785251 · Cited by 11
Jang, H., Ji, Y., Han, J., Khan, A. M., Ahn, J.-Y., & Han, C.-S. (2015) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-015-0329-1 · Cited by 11
Kinematic and Dynamic Modeling and Analysis of a Lower Extremity Exoskeleton
Yan, L., Shen, Q. “., Yang, D., Qiao, J. M., & Datseris, P. (2019) · International Conference on Ubiquitous Robots (UR) · doi:10.1109/urai.2019.8768556 · Cited by 12
“Some investigators tried to measure a human muscle’s activity information, such as myoelectricity [1], to predict the human leg’s movement and eliminate the lag between the wearer and the exoskeleton.”
BackgroundFunctional Electrical Stimulation in Paraplegia
Papachristos, A. (2014) · InTech eBooks · doi:10.5772/58625 · Cited by 13
“An ambulatory system named HAL that combines a powered exoskeleton with a customized walker was designed at the Sogang University [43-45].”
MethodHybrid Zero Dynamics Control of an Underactuated Lower-Limb Exoskeleton for Gait Guidance
Goo, A. C., Laubscher, C. A., & Sawicki, J. T. (2022) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.4053946 · Cited by 10
Goršič, M., & Novak, D. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111692 · Cited by 10
Creating the brain and interacting with the brain: an integrated approach to understanding the brain
Morimoto, J., & Kawato, M. (2015) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.1250 · Cited by 11
Akiyama, Y., Higo, I., Yamada, Y., & Okamoto, S. (2014) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2014.7090545 · Cited by 10
“Although there are other types of robots such as [8], these robots are not considered in this study because of the difference in their assistance strategies.”
BackgroundToda, H., Tada, M., Maruyama, T., & Kurita, Y. (2019) · Annual Conference of the Society of Instrument and Control Engineers of Japan (SICE) · doi:10.23919/sice.2019.8859803 · Cited by 10
“Robot suit HAL® is an exoskeleton designed to support hip and knee joint motion for the hemiplegia or paraplegia using bioelectric signal [6].”
BackgroundWatanabe, H., Marushima, A., Kadone, H., Shimizu, Y., Kubota, S., Hino, T., Sato, M., Ito, Y., Hayakawa, M., Tsurushima, H., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.666562 · Cited by 10
“The wearable cyborg Hybrid Assistive Limb (HAL) is the world’s first cyborg-type wearable device for supporting, improving, and expanding the wearer’s physical functions based on the detection of bioelectrical signals (BES) on the skin surface while a wearer attempts to generate muscle force (Lee and Sankai, 2005; Suz…”
BackgroundRobust LMI-Based State-Feedback Control of a Knee Exoskeleton Robotic System
Jenhani, S., & Gritli, H. (2023) · International Multi-Conference on Systems, Signals & Devices (SSD) · doi:10.1109/ssd58187.2023.10411217 · Cited by 11
“To control the position or the trajectory of the leg, stabilize the whole human/robot body at the zero moment position (ZMP), and assure gait rehabilitation, this control technique has been linked to the balance in the gravity, the friction, or the Coriolis force [13]–[17].”
MethodOutput feedback control of an actuated lower limb orthosis with bounded input
Lalami, M. E., Rifaï, H., Mohammed, S., Hassani, W., Fried, G., & Amirat, Y. (2013) · Industrial Robot the international journal of robotics research and application · doi:10.1108/ir-05-2013-363 · Cited by 10
Wearable exoskeletons for the physical treatment of children with quadriparesis
García, E., Cestari, M., & Sanz‐Merodio, D. (2014) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/humanoids.2014.7041395 · Cited by 10
“There are currently four commercially available wearable lower-limb orthotic devices designed for adult paraplegics [4], [5], [6], [7] and some ongoing research initiatives on the subject [8], [9], [10], but they have the following common shortcomings for their use in quadriparetic children:”
BackgroundUnplugged Powered Suit for Superhuman Tennis
Ogawa, K., Ikeda, T., & Kurita, Y. (2018) · France-Japan and Europe-Asia Congress on Mechatronics · doi:10.1109/mecatronics.2018.8495845 · Cited by 10
“These devices are of two types: active type [1-3], which is equipped with actuators; and passive type [4-6], which uses spring elements.”
BackgroundRobotic-Assisted Rehabilitation Trainer Improves Balance Function in Stroke Survivors
Ji, J., Song, T., Guo, S., Xi, F., & Wu, H. (2018) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2018.2883653 · Cited by 10
“[17] proposed an algorithm to estimate human intentions related to walking in order to support a paraplegia patient’s walk.”
BackgroundWall, A., Borg, J., & Palmcrantz, S. M. (2019) · Neurorehabilitation · doi:10.3233/nre-192929 · Cited by 12
Liu, Y.-H., Zhang, B., Liu, Q., Hsu, W.-C., Hsiao, Y.-T., Su, J.-Y., Kobayashi, Y., & Fujie, M. G. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319165 · Cited by 10
“exoskeleton system [1], walker [2], ankle-foot orthosis (AFO)”
BackgroundUser-robot collaborative excitation for PAM model identification in exoskeleton robots
Hamaya, M., Matsubara, T., Noda, T., Teramae, T., & Morimoto, J. (2017) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2017.8206145 · Cited by 10
A Wearable Body Controlling Device for Application of Functional Electrical Stimulation
Taghavi, N., Luecke, G. R., & Jeffery, N. D. (2018) · Sensors · doi:10.3390/s18041251 · Cited by 10
Hernández-Rámos, M. A., Cuautle, J. D. J. A. F., Filippeschi, A., Rodríguez-Jarquín, J. P., Landeta-Escamilla, O., Jacinto‐Villegas, J. M., & Sandoval-Gonzalez, O. O. (2022) · Applied Sciences · doi:10.3390/app12168098 · Cited by 10
Review of Power-Assisted Lower Limb Exoskeleton Robot
He, G., Huang, X., Li, F., & Wang, H. (2022) · Journal of Shanghai Jiaotong University (Science) · doi:10.1007/s12204-022-2489-3 · Cited by 9
“HAL-5 can realize various complex actions such as squatting, jumping, and running up and down stairs [22] , which fully embodies the man-machine coupling and makes the wearer feel quite comfortable.”
Active air mat for comfortable and easy to wear a forearm support system
Hasegawa, Y., Tayama, M., Saito, T., & Sankai, Y. (2011) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2011.6095120 · Cited by 9
“That is why a lot of exoskeleton systems are developed to support a healthy person [2], [3] and a physically challenged person [4], [5].”
BackgroundSelf-citationAn adaptive gait learning strategy for lower limb exoskeleton robot
Chen, C., Liu, D., Wang, X., Wang, C., & Wu, X. (2017) · IEEE International Conference on Real-time Computing and Robotics (RCAR) · doi:10.1109/rcar.2017.8311855 · Cited by 10
“Chunjie Chen, Duxin Liu,Xuesong Wang, Can Wang,and Xinyu Wu are with the Guangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of was up to 90%[5].”
BackgroundAndo, D., Yokota, C., Koshino, K., Yasuno, F., Sato, T., Yamamoto, A., Odani, H., Nakajima, T., Higuchi, T., & Tatsumi, E. (2020) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2020.116939 · Cited by 9
Kagawa, T., Nomura, T., & Kondo, S. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2020.3004873 · Cited by 9
“Rewalk, Exso, and HAL have motorized DOFs of hip and knee extension/flexion and passive ankle joints.”
BackgroundGeneralized Control Framework for Exoskeleton Robots by Interaction Force Feedback Control
Lee, H. J., Kim, K.-S., & Kim, S. (2021) · International Journal of Control Automation and Systems · doi:10.1007/s12555-020-0097-2 · Cited by 9
A Framework and Algorithm for Human-Robot Collaboration Based on Multimodal Reinforcement Learning
Cai, Z., Feng, Z., Zhou, L., Ai, C., Shao, H., & Yang, X. (2022) · Computational Intelligence and Neuroscience · doi:10.1155/2022/2341898 · Cited by 9
“[6] estimated the intention of a paraplegic patient using the reaction forces on the floor while walking and standing.”
Flexible Thermal Actuator Film for Monolithic Soft Micro Robot Process
Sassa, F., & Hayashi, K. (2018) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2018.8589717 · Cited by 9
“Supporting and enhancement of physical capability with body assistant devices[1] for elderly people is a promising way to solve the problem of labor shortage caused by aging society which many countries are facing.”
BackgroundOptimal Motor Point Search Using Mm-Order Electrode Arrays
Matsubara, S., Watanabe, T., Suzuki, T., Wakisaka, S., Aoyama, K., & İnami, M. (2023) · IEEE Access · doi:10.1109/access.2023.3285422 · Cited by 8
“…of measuring and processing human motor skills that can be controlled with millisecond-order precision and provide appropriate motor interventions (e.g., power-assist suit [1], human-machine mutual actuation [2], interactive systems for controlling a user’s motion [3], [4], and cognition [5], [6]).”
BackgroundPinching force accuracy affected by thumb sensation in human force augmentation
Hasegawa, Y., Ariyama, T., & Kamibayashi, K. (2012) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2012.6386081 · Cited by 8
“Some wearable-type support systems are developed to augment caregiver’s force for transfer assistance of elderly people and physically challenged person in daily activities [2], [3].”
BackgroundSelf-citationLe, D. T., Watanabe, K., Ogawa, H., Matsushita, K., Imada, N., Taki, S., Iwamoto, Y., Imura, T., Araki, H., Araki, O., et al. (2022) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2022.795079 · Cited by 8
“HALSJ provides robotic assistance for human limb movement by detecting bioelectrical signals from extensor-flexor muscle regions (Morishita and Inoue, 2016; Suzuki et al., 2016).”
BackgroundWall, A., Palmcrantz, S. M., Borg, J., & Gutierrez-Farewik, E. M. (2023) · Frontiers in Neurology · doi:10.3389/fneur.2023.1244287 · Cited by 9
Suzuki, K. (2014) · Springer eBooks · doi:10.1007/978-4-431-54159-2_7 · Cited by 8
“The HAL has already been used as an assistive tool for neuro-rehabilitation [4–6].”
MethodSelf-citationA systematic graph-based method for the kinematic synthesis of non-anthropomorphic wearable robots
Sergi, F., Accoto, D., Tagliamonte, N. L., Carpino, G., Pathiyil, L., & Guglielmelli, E. (2010) · IEEE Conference on Robotics, Automation and Mechatronics (RAM) · doi:10.1109/ramech.2010.5513204 · Cited by 8
“Robot kinematic chain is not a free design parameter for robotic exoskeletons, while wearable robots can be designed to have a possibly non-anthropomorphic kinematic structure, according to the classification introduced in [6].”
BackgroundRobust Repetitive Learning Control of Lower Limb Exoskeleton with Hybrid Electro-hydraulic System
Yang, Y. M., Huang, D., & Dong, X. (2018) · IEEE Data Driven Control and Learning Systems Conference (DDCLS) · doi:10.1109/ddcls.2018.8516005 · Cited by 8
“Besides, HAL (Hybrid Assistive Leg) is designed in University of Tsukuba [8], and a power assisting suit for assisting a nurse caring a patient is designed in Kanagawa Institute of Technology [9].”
BackgroundWatanabe, H., Koike, A., Pak, Y. J., Wu, L., Kubota, H., Konno, H., Sato, A., Kawamoto, H., Matsumura, A., Aonuma, K., et al. (2019) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2019.05.026 · Cited by 8
Self-citationGait-Event-Based human intention recognition approach for lower limb
Lu, X. M., Huang, F., Chen, Z., & Gu, J. J. (2018) · IEEE International Conference on Information and Automation (ICIA) · doi:10.1109/icinfa.2018.8812509 · Cited by 8
“The human intention recognition approach, which is regard as the extremely important issue in order to achieve the synchronization between the motion of exoskeleton robot and the actual human limb, has attracted the growing interest in recent years [11], [12].”
BackgroundMefoued, S. (2013) · IEEE International Joint Conference on Neural Network · doi:10.1109/ijcnn.2013.6706827 · Cited by 6
“The exoskeleton uses DC motors with a PD based control scheme [8], [9].”
MethodQuantitative performance analysis of muscle suit — Estimation by Oxyhemoglobin and deoxyhemoglobin
Muramatsu, Y., Kobayashi, H., Sato, Y. S., Jiaou, H., Hashimoto, T., & Kobayashi, H. (2011) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2011.6181301 · Cited by 10
Zhu, C., Oda, M., Luo, X., Watanabe, H., & Yan, Y. (2009) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2009.5420549 · Cited by 8
“On the other hand, some power assistive devices such as exoskeletons of HAL ([19], [20]) and BLEEX [21] are developed for augment human strength and endurance during locomotion.”
BackgroundMathematical modeling and control of lower extremity exoskeleton
Tanyıldızı, A. K., Yakut, O., & Taşar, B. (2018) · Biomedical Research - India · doi:10.4066/biomedicalresearch.29-18-509 · Cited by 7
“The classic PID control method is one of the most preferred feedback control methods in control systems [23,24].”
MethodThe influence of hip joint rotation of a physical assistant robot on curving motion
Kuboki, Y., Akiyama, Y., Okamoto, S., & Yamada, Y. (2020) · Advanced Robotics · doi:10.1080/01691864.2020.1857304 · Cited by 7
“Recently, physical assistant robots have been developed to provide assistance in activities of daily living and industrial tasks [1,2].”
BackgroundKogawa, M., Miura, K., YASUDA, K., Ishibashi, Y., & Tsuda, E. (2021) · European Journal of Physical and Rehabilitation Medicine · doi:10.23736/s1973-9087.21.06387-5 · Cited by 7
Autonomous low limb exoskeleton to suppress the body weight
Mir‐Nasiri, N., & Jo, H. S. (2017) · International Conference on Control, Automation and Robotics (ICCAR) · doi:10.1109/iccar.2017.7942659 · Cited by 7
Huang, Y., Chen, Y., Niu, J., & Song, R. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-65289-4_26 · Cited by 7
On-line Dynamic Gait Generation Model for Wearable Robot with User’s Motion Intention
Ren, H., Liu, D.-X., Li, N., He, Y., Yan, Z., & Wu, X. (2018) · IEEE International Conference on Information and Automation (ICIA) · doi:10.1109/icinfa.2018.8812568 · Cited by 7
Voluntary intention-driven rehabilitation robots for the upper limb
Huang, Y., Su, S. W., & Song, R. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814942-3.00007-6 · Cited by 7
Forearm muscle activity estimation based on anatomical structure of muscles
Okajima, S., Costa‐García, Á., Ueda, S., Yang, N., & Shimoda, S. (2022) · The Anatomical Record · doi:10.1002/ar.24910 · Cited by 7
Energy-efficient power assisting methods for periodic motions and its experimental verification
Hatada, K., & Hirata, K. (2012) · IEEE International Conference on Industrial Technology (ICIT) · doi:10.1109/icit.2012.6210046 · Cited by 7
Efficient Lower Limb Exoskeleton for Human Motion Assistance
Mir‐Nasiri, N. (2016) · Biosystems & biorobotics · doi:10.1007/978-3-319-46532-6_48 · Cited by 7
Yu, Y. T., & Liang, W. (2012) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2012.6225383 · Cited by 6
“Power assisting robots, which are usually conceived as systems including upper extremities, lower extremities, or both, is also called as exoskeletons, where Hardiman project [3], BLEEX [4], Wearable Power Suit [5], HAL [6] and so on are such famous robots among present research.”
BackgroundStyle-phase adaptation of human and humanoid biped walking patterns in real systems
Matsubara, T., 宇都, 太., Noda, T., Teramae, T., & Morimoto, J. (2014) · IEEE-RAS International Conference on Humanoid Robots (Humanoids) · doi:10.1109/humanoids.2014.7041348 · Cited by 6
Human Gait-Phase Classification to Control a Lower Extremity Exoskeleton Robot
Kim, H. (2014) · 한국통신학회논문지 · doi:10.7840/kics.2014.39b.7.479 · Cited by 6
Gesteme-free context-aware adaptation of robot behavior in human–robot cooperation
Nessi, F., Beretta, E., Gatti, C., Ferrigno, G., & Momi, E. D. (2016) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2016.10.001 · Cited by 8
Super Twisting Control of Passive Gait Training Exoskeleton Driven by Pneumatic Muscles
Zhang, M., Huang, J., Cao, Y., & Zhang, H. (2019) · International Symposium on Micro-NanoMechatronics and Human Science · doi:10.1109/mhs48134.2019.9249319 · Cited by 6
An Analysis of Recovery Motion of a Man Wearing Physical Assistant Robot in Response to Collision
Akiyama, Y., Kushida, R., Yamada, Y., & Okamoto, S. (2015) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2015.195 · Cited by 6
“Physical assistant robots, which are attached to a human body and apply torque through cuffs and shoes, are thought to be effective solutions to such social problems because they can assist in the activities of daily living and rehabilitation of the wearer [1], [2].”
BackgroundA fast kinematic-based control method for lower-limb power augmentation exoskeleton
Taherifar, A., Vossoughi, G., Ghafari, A. S., & Jokar, M. (2014) · RSI International Conference on Robotics and Mechatronics (ICRoM) · doi:10.1109/icrom.2014.6990981 · Cited by 6
“In some researches the GRF sensors are used together with other sensors in the control architectures [17], while in other researches the control system is based on the GRF merely [4, 6].”
MethodEvent-triggered sliding mode controller design for lower limb exoskeleton
Liu, J., Wang, J., & Zhang, G. (2020) · Chinese Control Conference (CCC) · doi:10.23919/ccc50068.2020.9189571 · Cited by 6
“In [6], the exoskeleton called HAL-5 (Hybrid Assistive Limb) uses DC motors with a PD based control scheme.”
Jenhani, S., Gritli, H., & Narayan, J. (2024) · International Conference on Control, Decision and Information Technologies (CoDIT) · doi:10.1109/codit62066.2024.10708186 · Cited by 6
“Motorized orthoses are utilized for this purpose, employing control mechanisms to address friction or gravity forces, ensuring gait rehabilitation, stabilizing body posture, and regulating leg trajectory [12]–[15].”
BackgroundHasegawa, Y., & Suzuki, T. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139890 · Cited by 6
Self-citationFukui, Y., Akiyama, Y., Yamada, Y., & Okamoto, S. (2017) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2017.8122659 · Cited by 6
“The PARs for gait rehabilitation in hospitals have been developed [1], [2].”
BackgroundRole of Gait Training in Recovery of Standing and Walking in Subjects with Spinal Cord Injury
Arazpour, M., Sharifi, G., Mousavi, M. E., & Maleki, M. (2018) · InTech eBooks · doi:10.5772/intechopen.71312 · Cited by 6
“The successful orthotic gait rehabilitation in SCI subjects related to the several factors included well-motivated, with complete level of injury at T9 or below, incomplete level of injury, postural control, and [39–41] good upper extremity strength, as well as less spasticity and low level contractures [42], reduced…”
BackgroundStairs Reconstruction with 3D Point Cloud for Gait Generation of Lower Limb Exoskeleton Robot
Feng, Y., Xia, L., He, Y., Wang, C., Yan, Z., & Wu, X. (2019) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio49542.2019.8961511 · Cited by 6
Cha, D., Oh, S. N., Lee, H. H., Kim, K.-S., Kim, K. I., & Kim, S. (2015) · Journal of Electrical Engineering and Technology · doi:10.5370/jeet.2015.10.6.2376 · Cited by 6
“The robot suit Hybrid Assistive Limb (HAL) makes use of such bio-electrical signals, including ElectroMyoGraphy (EMG), and Floor Reaction Force (FRF), to detect the walking intention including step initiation of the operator before the corresponding visible movements occur [10-11].”
BackgroundMatsubara, T., Uchikata, A., & Morimoto, J. (2015) · Biological Cybernetics · doi:10.1007/s00422-015-0663-5 · Cited by 6
“In exoskeleton robot control, the robot’s center of pressure (CoP) is utilized to estimate user intentions and then as a trigger in a finitestate machine controller for user-adaptive walking support (Suzuki et al. 2007).”
Method
Metadata
- Authors
- Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y.
- Affiliations
- University of Tsukuba (JP)
- Japan Association for the Advancement of Medical Equipment (JP)
- Venue
- Advanced Robotics
- Publisher
- Informa UK Limited
- Published
- 2007-01-01
- Volume
- 21
- Issue
- 12
- Pages
- 1441-1469
- ISSN
- 0169-1864 (ISSN-L)
- 1568-5535
- OpenAlex
- W4236113979
- Cited by
- 474
- References
- 5
- Citations by year
- 2026: 6 · 2025: 14 · 2024: 13 · 2023: 44 · 2022: 24 · 2021: 33 · 2020: 28 · 2019: 31 · 2018: 56 · 2017: 44 · 2016: 26 · 2015: 31 · 2014: 28 · 2013: 29 · 2012: 24
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advanced Robotics (publishedVersion)
- Funders
- Ministry of Education, Science and Technology
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- paraplegia, Hybrid Assistive Limb, walking support, intention inference, ground reaction force, weight shifting, gait assistance, fall prevention, assistive robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.