Intention-based walking support for paraplegia patients with Robot Suit HAL
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper proposes an algorithm to estimate human intentions related to walking in order to comfortably and safely support a paraplegia patient's walk. Robot Suit HAL (Hybrid Assistive Limb) has been developed for enhancement of a healthy person's activities and for support of a physically challenged person's daily life. The assisting method based on bioelectrical signals such as myoelectricity successfully supports a healthy person's walking. These bioelectrical signals, however, cannot be measured properly from a paraplegia patient. Therefore another interface that can estimate a patient's intentions without any manual controller is desired for robot control since a manual controller deprives a patient of his/her hand freedom. Estimation of a patient's intentions contributes to providing not only comfortable support but also safe support, because any inconformity between the robot suit motion and the patient motion results in his/her stumbling or falling. The proposed algorithm estimates a patient's intentions from a floor reaction force (FRF) reflecting a patient's weight shift during walking and standing. The effectiveness of this algorithm is investigated through experiments on a paraplegia patient who has a sensory paralysis on both legs, especially his left leg. We show that HAL supports the patient's walk properly, estimating his intentions based on the FRF, while he keeps his own balance by himself.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“To date, trajectory tracking control is primarily used in LEEs for early stage rehabilitation when patients have very weak muscle strength [58], [59].”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [59]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hybrid Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Steger, R., & Huang, L. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906065505 · Cited by 382 · cited 1×
“Keywords: Robot suit; paraplegia; walking support; intention estimation; floor reaction force.”
BackgroundPower assist method based on Phase Sequence and muscle force condition for HAL
Kawamoto, H., & Sankai, Y. (2005) · Advanced Robotics · doi:10.1163/1568553054455103 · Cited by 381 · cited 1×
“Keywords: Robot suit; paraplegia; walking support; intention estimation; floor reaction force.”
BackgroundSelf-citationPower Assist System HAL-3 for Gait Disorder Person
Kawamoto, H., & Sankai, Y. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-45491-8_43 · Cited by 346 · cited 1×
“Keywords: Robot suit; paraplegia; walking support; intention estimation; floor reaction force.”
BackgroundSelf-citationLee, S., & Sankai, Y. (2003) · IEEE/RSJ International Conference on Intelligent Robots and System · doi:10.1109/irds.2002.1043967 · Cited by 291 · cited 1×
“Keywords: Robot suit; paraplegia; walking support; intention estimation; floor reaction force.”
BackgroundSelf-citationSato, M., Ikeuchi, H., Katoh, R., & Yamashita, T. (1993) · TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C · doi:10.1299/kikaic.59.3101 · Cited by 3
Research works printed but not linked: 7
- Junpei Okamura, Hiroshi Tanaka and Yoshiyuki Sankai, EMG-based Prototype Powered Assistive System for Walking Aid, in Proc. of Asian Symposium on Industrial Automation and Robotics (ASIAR'99) , Bangkok, pp.229-234 (1999).
- Takao Nakai, Suwoong Lee, Hiroaki Kawamoto and Yoshiyuki Sankai, Development of Powered Assistive Leg for Walking Aid using EMG and Linux, in Proc. of Asian Symposium on Industrial Automation and Robotics (ASIAR'01) , Bangkok, pp.295-299 (2001).
- Jerry E. Pratt, Benjamin T. Krupp, Christopher J. Morse and Steven H. Collins, The RoboKnee: An Exoskeleton for Enhancing Strength and Endurance During Walking, in Proc. of the 2004 IEEE International Conference on Robotics and Automation (ICRA '04) , New Orleans, pp.2430-2435 (2004).
- Takahiko Nakamura, Kazunari Saito and Kazuhiro Kosuge, Control of Wearable Walking Support System Based on Human-Model and GRF, Proc. of the 2005 IEEE International Conference on Robotics and Automation (ICRA '05) , Barcelona, pp. 4405-4410 (2005).
- Ryan Steger, Sung Hoon Kim and H. Kazerooni, Control Scheme and Networked Control Architecture for the Berkeley Lower Extremity Exoskeleton (BLEEX), in Proc. of the 2006 IEEE International Conference on Robotics and Automation (ICRA '06) , Orlando, Florida, pp. 3469-3476 (2006).
- H. Ikeuchi, K. Shinkoda, R. Katoh, M.Sato, T. Yamashita, Analysis of Human Transient Walking by Wavelet Transform, Proc. of The Third International Symposium on Artificial Life and Robotics , Beppu, Japan, pp.695-698 (1998).
- Suzuki K., Kawamura Y., Hayashi T., Sakurai T., Hasegawa Y. and Sankai Y., IntentionBased Walking Support for Paraplegia Patient, Proc. of the 2005 IEEE International Conference on Systems, Man and Cybernetics (SMC2005) , Hawaii, pp.2707-2713 (2005).
Cited by
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
“Only kinematics results were analyzed and proved the feasibility of the whole system as well as the reliability of the intention estimator [29].”
BackgroundRecent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
“To date, trajectory tracking control is primarily used in LEEs for early stage rehabilitation when patients have very weak muscle strength [58,59].”
MethodHAL: Hybrid Assistive Limb Based on Cybernics
Sankai, Y. (2010) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-642-14743-2_3 · Cited by 479
“In this chaper, the Cybernic Autonomous Control among the cybernic control systems is applied to HAL in order to support a paraplegia patient's walking[6].”
MethodSelf-citationLower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 455
“It should also be noted that the endurance of the wearers could not be improved significantly using HAL-5.”
MethodInfluentialIntention-Based EMG Control for Powered Exoskeletons
Lenzi, T., De Rossi, S. M. M., Vitiello, N., & Carrozza, M. C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2198821 · Cited by 400
Metadata
- Authors
- Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y.
- Affiliations
- University of Tsukuba (JP)
- Japan Association for the Advancement of Medical Equipment (JP)
- Venue
- Advanced Robotics
- Publisher
- Informa UK Limited
- Published
- 2007-01-01
- Volume
- 21
- Issue
- 12
- Pages
- 1441-1469
- ISSN
- 0169-1864 (ISSN-L)
- 1568-5535
- OpenAlex
- W4236113979
- Cited by
- 474
- References
- 5
- Citations by year
- 2026: 6 · 2025: 14 · 2024: 13 · 2023: 44 · 2022: 24 · 2021: 33 · 2020: 28 · 2019: 31 · 2018: 56 · 2017: 44 · 2016: 26 · 2015: 31 · 2014: 28 · 2013: 29 · 2012: 24
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Advanced Robotics (publishedVersion)
- Funders
- Ministry of Education, Science and Technology
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- paraplegia, Hybrid Assistive Limb, walking support, intention inference, ground reaction force, weight shifting, gait assistance, fall prevention, assistive robotics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.