Acid–base surface free energies of solids and the definition of scales in the Good–van Oss–Chaudhury theory
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
The overwhelming basicity of all analysed surfaces strongly dependent on the choice of liquid triplet used for contact angle measurements and the negative values sometimes obtained for the square roots of the acid-base parameters can be summarized as the main problems arising from the application of the Good-van Oss-Chaudhury (GvOC) theory to the calculation of Lewis acid-base properties of polymer surfaces from contact angle data. This paper tries to account for these problems, namely: (1) the Lewis base, or electron donor component, is much greater than the Lewis acid or electron-acceptor component because of the reference values for water chosen in the original GvOC theory. A direct comparison of the acidic component with the basic one of the same materials has no meaning. A new reference scale for water which is able to overcome this problem is suggested. For the calculation of acid-base components, a best-fit approach is proposed which does not require any starting information about the liquids or polymers and can yield estimates of the acid-base parameters for both the liquids and the polymers involved; (2) the strong dependence of the value of the acid-base components on the three liquids employed is due to ill-conditioning of the related set of equations, an intrinsic and purely mathematical feature which cannot be completely cured by any realistic improvement in experimental accuracy. To reduce or eliminate the effect, one only needs a proper set of liquids, representative of all kinds of different solvents; (3) the negative coefficients appear as a simple consequence of measurement uncertainty, combined with the possible ill-conditioning of the equation set. We cannot exclude, however, that in some cases they could have a different origin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Intermolecular and Surface Forces · doi:10.1016/b978-0-12-391927-4.10024-6 · Cited by 16,923
(1999) · Choice Reviews Online · doi:10.5860/choice.37-0940 · Cited by 14,314 · cited 1×
“A very intriguing idea can be the use of hydrogen peroxide; its surface free energy is similar to that of water, about 76 mJ/m2, while it is estimated to be about 10(6) times less basic than water [60]!”
BackgroundOrville-Thomas, W. J. (1973) · Journal of Molecular Structure · doi:10.1016/0022-2860(73)85197-x · Cited by 6,806
Faires, J. D. (1978) · Cited by 6,711
III. An essay on the cohesion of fluids
Young, T. (1805) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1805.0005 · Cited by 6,643
Kamlet, M. J., Abboud, J. L. M., Abraham, M. H., & Taft, R. W. (1983) · The Journal of Organic Chemistry · doi:10.1021/jo00165a018 · Cited by 3,428
Polymer Interface and Adhesion
Wu, S. (2017) · Routledge eBooks · doi:10.1201/9780203742860 · Cited by 3,379
ATTRACTIVE FORCES AT INTERFACES
Fowkes, F. M. (1964) · Industrial & Engineering Chemistry · doi:10.1021/ie50660a008 · Cited by 3,302
Pimentel, G. C., McClellan, A. L., & Hayward, R. (1960) · Medical Entomology and Zoology · Cited by 3,268
Abraham, M. H. (1993) · Chemical Society Reviews · doi:10.1039/cs9932200073 · Cited by 1,968
Surface and Interfacial Aspects of Biomedical Polymers
(1985) · Springer eBooks · doi:10.1007/978-1-4684-8610-0 · Cited by 1,284
SURFACE ANALYSIS - "Interdisciplinary Aspects of Surface Phenomena"
Bonis, L. J. (1964) · Industrial & Engineering Chemistry · doi:10.1021/ie50655a007 · Cited by 1,239
Interfacial Forces in Aqueous Media
Visser, H. (1995) · Powder Technology · doi:10.1016/0032-5910(95)90005-5 · Cited by 880
van Oss, C. J., Chaudhury, M. K., & Good, R. J. (1987) · Advances in Colloid and Interface Science · doi:10.1016/0001-8686(87)80008-8 · Cited by 865
Correlation between substratum roughness and wettability, cell adhesion, and cell migration
Lampin, M., Warocquier-Cl�rout, R., Legris, C., Degrange, M., & Sigot-Luizard, M. F. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199707)36:1<99::aid-jbm12>3.0.co;2-e · Cited by 777
Contact Angle Hysteresis. III. Study of an Idealized Heterogeneous Surface
Johnson, R. E., & Dettre, R. H. (1964) · The Journal of Physical Chemistry · doi:10.1021/j100789a012 · Cited by 688
Valence and the structure of atoms and molecules
Leffmann, H. (1923) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(23)90893-8 · Cited by 680
Valence and the structure of atoms and molecules
Lewis, G. N. (1923) · Cited by 390
Some Reflections on Acid–Base Solid Surface Free Energy Theories
Volpe, C. D., & Siboni, S. (1997) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1997.5124 · Cited by 380
Self-citationAcid-base interactions: Relevance to adhesion science and technology
Allen, K. W. (1992) · International Journal of Adhesion and Adhesives · doi:10.1016/0143-7496(92)90035-t · Cited by 311
Direct Force Measurements between Silica and Alumina
Larson, I. C., Drummond, C. J., Chan, D. Y. C., & Grieser, F. (1997) · Langmuir · doi:10.1021/la960684h · Cited by 146
Quantitative evaluation and prediction of donor-acceptor interactions
Drago, R. S. (2006) · Springer eBooks · doi:10.1007/bfb0036784 · Cited by 98
The total surface free energy and the contact angle in the case of low energetic solids
Jańczuk, B., & Białopiotrowicz, T. (1990) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(90)90356-s · Cited by 41
Relevance of the density-functional theory to acid-base interactions and adhesion in solids
Lee, L. (1991) · Journal of Adhesion Science and Technology · doi:10.1163/156856191x00837 · Cited by 40
Characterization of polystyrene surface by a modified two-liquid laser contact angle goniometry
Qin, X., & Chang, W. V. (1995) · Journal of Adhesion Science and Technology · doi:10.1163/156856195x00725 · Cited by 32
Adhesion and Surface-Hydrogen-Bond Components for Polymers and Biomaterials
Lee, L.-H. (1998) · The Journal of Adhesion · doi:10.1080/00218469808011096 · Cited by 19
Cited by
Biological responses to physicochemical properties of biomaterial surface
Rahmati, M., Silva, E. A., Reseland, J. E., A. Heyward, C., & Haugen, H. J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00103a · Cited by 391
Experimental antimicrobial orthodontic adhesives using nanofillers and silver nanoparticles
Ahn, S.-J., Lee, S.-J., Kook, J.-K., & Lim, B.-S. (2009) · Dental Materials · doi:10.1016/j.dental.2008.06.002 · Cited by 340
The role of surface free energy in osteoblast–biomaterial interactions
Gentleman, M. M., & Gentleman, E. (2014) · International Materials Reviews · doi:10.1179/1743280414y.0000000038 · Cited by 216
Physico-chemical surface properties of microalgae
Ozkan, A., & Berberoglu, H. (2013) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2013.08.001 · Cited by 166
Metadata
- Authors
- Della Volpe, C., & Siboni, S.
- Venue
- Journal of Adhesion Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2000-01
- Volume
- 14
- Issue
- 2
- Pages
- 235-272
- ISSN
- 0169-4243 (ISSN-L)
- 1568-5616
- OpenAlex
- W2000153800
- Cited by
- 194
- References
- 26
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.