The DOI matches its Crossref record.
Polyaniline, an electroactive polymer, supports adhesion and proliferation of cardiac myoblasts
Abstract
Conductive polymers, such as polypyrrole, have recently been studied as potential surfaces/matrices for cell- and tissue-culture applications. We have investigated the adhesion and proliferation properties of H9c2 cardiac myoblasts on a conductive polyaniline substrate. Both the non-conductive emeraldine base (PANi) and its conductive salt (E-PANi) forms of polyaniline were found to be biocompatible, viz., allowing for cell attachment and proliferation and, in the case of E-PANi, maintaining electrical conductivity. By comparison to tissue-culture-treated polystyrene (TCP), the initial adhesion of H9c2 cells to both PANi and E-PANi was slightly reduced by 7% (P < 0.05, n = 18). By contrast, the overall rate of cell proliferation on the conductive surfaces, although initially decreased, was similar to control TCP surfaces. After 6 days in culture on the different surfaces, the cells formed confluent monolayers which were morphologically indistinguishable. Furthermore, we observed that E-PANi, when maintained in an aqueous physiologic environment, retained a significant level of electrical conductivity for at least 100 h, even though this conductivity gradually decreased by about 3 orders of magnitude over time. These results demonstrate the potential for using polyaniline as an electroactive polymer in the culture of excitable cells and open the possibility of using this material as an electroactive scaffold for cardiac and/or neuronal tissue engineering applications that require biocompatibility of conductive polymers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Ghasemi-Mobarakeh, L., Prabhakaran, M. P., Morshed, M., Nasr-Esfahani, M. H., Baharvand, H., Kiani, S., Al-Deyab, S. S., & Ramakrishna, S. (2011) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.383 · Cited by 698
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691
Dong, R., Zhao, X., Guo, B., & Ma, P. X. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b04911 · Cited by 538
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Metadata
- Authors
- Bidez, P. R., Li, S., MacDiarmid, A. G., Venancio, E. C., Wei, Y., & Lelkes, P. I.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 2006-01
- Volume
- 17
- Issue
- 1-2
- Pages
- 199-212
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W2059976370
- Cited by
- 330
- References
- 0
- FWCI
- 7.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polyaniline, an electroactive polymer, supports adhesion and proliferation of cardiac myoblasts. https://app.cochat.ai/papers/10.1163/156856206774879180
- The paper
- Bidez, P. R., Li, S., MacDiarmid, A. G., Venancio, E. C., Wei, Y., & Lelkes, P. I. (2006). Polyaniline, an electroactive polymer, supports adhesion and proliferation of cardiac myoblasts. Journal of Biomaterials Science, Polymer Edition. https://doi.org/10.1163/156856206774879180
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.