Hepatocyte spheroid culture on a polydimethylsiloxane chip having microcavities
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A two-dimensional microarray technique of spherical multicellular aggregates (spheroids) using a microfabricated polydimethylsiloxane (PDMS) chip and the expression of liver-specific functions of primary rat hepatocytes on the chip were investigated. The PDMS chip, which was fabricated by a photolithography-based technique, consisted of approximately 2500 cylindrical microcavities (approximately 1100 cavities/cm2) in a triangular arrangement of 330 microm pitch on a PDMS plate (20 x 20 mm); each cavity measured 300 microm in diameter and 100 microm in depth. Most hepatocytes on the PDMS chip gradually gathered and subsequently formed a single spheroid in each cavity until 3 days of culture. A part of the spheroid was attached to the bottom or wall surface of the microcavity, and the spheroid configuration was maintained for at least 14 days of culture. Albumin secretion, ammonia removal and ethoxyresorufin O-dealkylase (EROD) activity, which is a cytochrome P-450-dependent reaction, of hepatocytes on the PDMS chip were higher than those of a monolayer dish or a flat PDMS dish without microcavities, and were maintained for at least 10 days of culture. The spheroid microarray technique appears to be promising in the development of cell chips and microbioreactors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional behavior of primary rat liver cells in a three-dimensional perfused microarray bioreactor
Powers, M. J., Janigian, D. M., Wack, K. E., Baker, C. S., Stolz, D. B., & Griffith, L. G. (2002) · Tissue Engineering · doi:10.1089/107632702760184745 · Cited by 234
Cited by
Organ printing: from bioprinter to organ biofabrication line
Mironov, V., Kasyanov, V., & Markwald, R. R. (2011) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2011.02.006 · Cited by 343
Fowler, S., Chen, W. L. K., Duignan, D. B., Gupta, A., Hariparsad, N., Kenny, J. R., Lai, W. G., Liras, J., Phillips, J. A., & Gan, J. (2020) · Lab on a Chip · doi:10.1039/c9lc00857h · Cited by 109
Technique for the control of spheroid diameter using microfabricated chips
Sakai, Y., & Nakazawa, K. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.06.004 · Cited by 94
Self-citationRoles of Spheroid Formation of Hepatocytes in Liver Tissue Engineering
Jiang, H.-L., Kim, Y.-K., Cho, K.-H., Jang, Y.-C., Choi, Y.-J., Chung, J.-H., & Cho, C.-S. (2010) · International Journal of Stem Cells · doi:10.15283/ijsc.2010.3.2.69 · Cited by 22
“fabricated polydimethylsiloxane (PDMS) chip having microcavities by a photolithography technique and evaluated liver-specific functions (15).”
Method
Metadata
- Authors
- Nakazawa, K., Izumi, Y., Fukuda, J., & Yasuda, T.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 2006-01
- Volume
- 17
- Issue
- 8
- Pages
- 859-873
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W2014498405
- Cited by
- 52
- References
- 1
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.