CoChat

Properties of shape memory polyurethane used as a low-temperature thermoplastic biomedical orthotic material: influence of hard segment content

Meng, Qinghao, Hu, Jinlian, Zhu, Yong · 2008 · Journal of Biomaterials Science, Polymer Edition
Cited by 43

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

A series of PCL-based shape memory polyurethanes was synthesized via bulk pre-polymerization. Their thermal, mechanical properties, shape memory properties, softening and hardening processes were investigated by the experimental approach and made comparison with a commercially available orthotic material. The cytotoxicity of the low-temperature thermoplastic polyurethane was tested. The results suggest that the soft segment phase of the shape memory polyurethanes has a melting transition at about 36-46 degrees C, which makes them possible low-temperature thermoplastic materials. The hard segment phase has a two-fold effect on the shape memory polyurethane as a low-temperature thermoplastic orthotic material: increasing tensile mechanical strength at room temperature, which enables it to be used in circumstances where high tensile strength is required; and reducing low-temperature malleability and fixity ratio, which make it difficult to fabricate orthotic devices. To obtain a shape memory polyurethane with excellent low-temperature thermoplastic properties for orthopaedical surgical use, the hard segment content should not be above 22 wt%. At last, a prototype wrist orthosis was easily fabricated at 60 degrees C with hand using a shape memory polyurethane with 16 wt% hard segment content. Cytotoxicity tests indicate that the wrist orthotic material is not cytotoxic.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1163/156856208786140355

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 43

Metadata

Authors
Meng, Q., Hu, J., & Zhu, Y.
Venue
Journal of Biomaterials Science, Polymer Edition
Published
2008-01
Volume
19
Issue
11
Pages
1437-1454
ISSN
  • 0920-5063 (ISSN-L)
  • 1568-5624
OpenAlex
W2077746238
Cited by
43
References
4
FWCI
1.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Properties of shape memory polyurethane used as a low-temperature thermoplastic biomedical orthotic material: influence of hard segment content. https://app.cochat.ai/papers/10.1163/156856208786140355
The paper
Meng, Q., Hu, J., & Zhu, Y. (2008). Properties of shape memory polyurethane used as a low-temperature thermoplastic biomedical orthotic material: influence of hard segment content. Journal of Biomaterials Science, Polymer Edition. https://doi.org/10.1163/156856208786140355

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.