A Low-Temperature Thermoplastic Anti-bacterial Medical Orthotic Material Made of Shape Memory Polyurethane Ionomer: Influence of Ionic Group
The DOI matches its Crossref record; 37 of the 39 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
PCL-based shape memory polyurethane ionomers with quaternarized pyridine moieties incorporated through molecular extension were synthesized. These polyurethanes were specifically designed as low-temperature thermoplastic anti-bacterial orthotic materials. A commercialized orthotic material was employed for comparison. The influence of ionic groups on the properties of orthotic materials was studied. The anti-bacterial properties and cytotoxicity of the polyurethane ionomer were tested. It was found that, different from other researchers' conclusions, the Coulombic force among cationic groups and the increased cohesion among hard segments after ionization could lead to polyurethane with better phase separation, soft segment phase crystallability and hard segment phase stability. The results of this work indicated that, although the ionic group had the function of improving phase separation, the asymmetric extender had a negative effect on the hard segment phase stability. Several of the main physical properties of the synthesized polyurethane as orthortic materials were studied. The materials mechanical properties at using temperature (ambient temperature 22 degrees C) were improved so it may be used in circumstances where high mechanical strength is required. The fixity ratio was increased; as a result the material may fix shape more precisely according to patient affected parts. At last, a prototype wrist orthotic device was fabricated by hands. The orthotic device percent reductions against Klebsiella pneumoniae and Staphylococcus aureus were 96.2% and 100%, respectively. The anti-bacterial activity rating of this device was acceptable and significant according to ASTM E 2149. Cytotoxicity tests indicated that the wrist orthotic material was not cytotoxic.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Cytotoxicity testing by use of the agarose overlay assay with L929 mouse fibroblasts revealed no adverse effects of the materials on these cells [73].”
From Shape-memory polymers as a technology platform for biomedical applications (2010) · cites this paper as [73]
In the citing paper
“In addition, PCL-based shape-memory polyurethane ionomers with quaternarized pyridine moieties proved to be suited to reduce the bacterial activity of Klebsiella pneumoniae (-96.2%) and Staphylococcus aureus (-100%).”
From Shape-memory polymers as a technology platform for biomedical applications (2010) · cites this paper as [73]
Citations
Cites
Lendlein, A., & Kelch, S. (2002) · Kirk-Othmer Encyclopedia of Chemical Technology · doi:10.1002/0471238961.1908011612051404.a01 · Cited by 2,566
Biodegradable, Elastic Shape-Memory Polymers for Potential Biomedical Applications
Lendlein, A., & Langer, R. (2002) · Science · doi:10.1126/science.1066102 · Cited by 2,146
Crescenzi, V., Manzini, G., Calzolari, G., & Borri, C. (1972) · European Polymer Journal · doi:10.1016/0014-3057(72)90109-7 · Cited by 750
Hepburn, C. (1992) · Springer eBooks · doi:10.1007/978-94-011-2924-4 · Cited by 695
Polyurethanes having shape memory effects
Kim, B. K., Lee, S. Y., & Xu, M. (1996) · Polymer · doi:10.1016/s0032-3861(96)00442-9 · Cited by 693
Shape-memory materials and hybrid composites for smart systems: Part I Shape-memory materials
Wei, Z. G., Sandstroröm, R., & Miyazaki, S. (1998) · Journal of Materials Science · doi:10.1023/a:1004692329247 · Cited by 574
Dufresne, A., Dupeyre, D., & Vignon, M. R. (2000) · Journal of Applied Polymer Science · doi:10.1002/(sici)1097-4628(20000628)76:14<2080::aid-app12>3.0.co;2-u · Cited by 523
Korley, L. T. J., Pate, B. D., Thomas, E. L., & Hammond, P. T. (2006) · Polymer · doi:10.1016/j.polymer.2006.02.093 · Cited by 366
Crystal structure of poly-ε-caprolactone
Bittiger, H., Marchessault, R. H., & Niegisch, W. D. (1970) · Acta Crystallographica Section B Structural Crystallography and Crystal Chemistry · doi:10.1107/s0567740870005198 · Cited by 340
Polyurethane ionomers having shape memory effects
Kim, B. K., Lee, S. Y., Lee, J. S., Baek, S. H., Choi, Y. J., Lee, J. O., & Xu, M. (1998) · Polymer · doi:10.1016/s0032-3861(97)00616-2 · Cited by 215
Research works printed but not linked: 8
- 10.1002/(sici)1097-4628(19980822)69:8<1575::aid-app12>3.0.co;2-u · DOI · Paper page
- Li F. K., 1996, J. Appl. Polym. Sci., 64, 1511
- Hyashi S., 1993, Int. Prog. Urethanes, 6, 90
- Hayashi S., 2004, Mitsubishi Heavy Ind. Techn. Rev., 41, 1
- Takahashi T., 1998, J. Appl. Polym. Sci., 60, 1061, 10.1002/(sici)1097-4628(19960516)60:7<1061::aid-app18>3.0.co;2-3 · DOI · Paper page
- Guantillake P. A., 2000, J. Appl. Polym. Sci., 76, 2026, 10.1002/(sici)1097-4628(20000628)76:14<2026::aid-app5>3.0.co;2-x · doi:10.1002/(sici)1097-4628(20000628)76:14<2026::aid-app5>3.0.co;2-x
- Meng Q. H., 2008, Polym. Adv. Technol.
- 10.1016/0032-3861(96)00166-8 · DOI · Paper page
Cited by
A review of stimuli-responsive shape memory polymer composites
Meng, H., & Li, G. (2013) · Polymer · doi:10.1016/j.polymer.2013.02.023 · Cited by 1,190
A review of shape memory polymer composites and blends
Meng, Q., & Hu, J. (2009) · Composites Part A: Applied Science and Manufacturing · doi:10.1016/j.compositesa.2009.08.011 · Cited by 609
Self-citationShape-memory polymers as a technology platform for biomedical applications
Lendlein, A., Behl, M., Hiebl, B., & Wischke, C. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.8 · Cited by 469
A review of shape memory polymers bearing reversible binding groups
Lewis, C. L., & Dell, E. M. (2016) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.23994 · Cited by 167
Xiao, R., & Huang, W. (2020) · Macromolecular Bioscience · doi:10.1002/mabi.202000108 · Cited by 119
Metadata
- Authors
- Meng, Q., Hu, J., Liu, B., & Zhu, Y.
- Affiliations
- Hong Kong Polytechnic University (HK)
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 2009-01
- Volume
- 20
- Issue
- 2
- Pages
- 199-218
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W1971108758
- Cited by
- 22
- References
- 39
- Citations by year
- 2023: 1 · 2020: 3 · 2019: 1 · 2018: 1 · 2017: 3 · 2016: 2 · 2014: 1 · 2013: 1 · 2012: 2
- FWCI
- 2.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomaterials Science Polymer Edition (publishedVersion)
- PubMed (publishedVersion)
- PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
- Funders
- Innovation and Technology Fund
- Topics
- Physical Sciences › Materials Science › Polymers and Plastics › Polymer composites and self-healing
- Life Sciences › Immunology and Microbiology › Applied Microbiology and Biotechnology › Antimicrobial agents and applications
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
- Keywords
- ionic groups, antibacterial activity, phase separation, soft segment crystallinity, Klebsiella pneumoniae, Staphylococcus aureus, cytotoxicity, polyurethane synthesis
- MeSH terms
- Animals, Anti-Bacterial Agents, Calorimetry, Differential Scanning, Cell Line, Cold Temperature, Fibroblasts, Humans, Ions, Microbial Sensitivity Tests, Orthotic Devices, Polyurethanes, Pyridines, Tensile Strength, X-Ray Diffraction, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Low-Temperature Thermoplastic Anti-bacterial Medical Orthotic Material Made of Shape Memory Polyurethane Ionomer: Influence of Ionic Group. https://app.cochat.ai/papers/10.1163/156856209x404497
- The paper
- Meng, Q., Hu, J., Liu, B., & Zhu, Y. (2009). A Low-Temperature Thermoplastic Anti-bacterial Medical Orthotic Material Made of Shape Memory Polyurethane Ionomer: Influence of Ionic Group. Journal of Biomaterials Science, Polymer Edition. https://doi.org/10.1163/156856209x404497
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.