Inhibition of fibroblast cell adhesion on substrate by coating with 2-methacryloyloxyethyl phosphorylcholine polymers
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Fibroblast adhesion and growth behavior were examined on various polymers coated on a poly(ethylene telephthalate) (PET) substrate. The polymers are poly[2-methacryloyloxyethyl phosphorylcholine (MPC)-co-n-butyl methacrylatel copolymer (PMB)s with different MPC unit compositions, and poly(2-hydroxyethyl methacrylate). Surface analysis by dynamic contact angle measurement revealed that the mobility of the polymer chain on the PET substrate depended on the MPC unit composition, but there was no significant difference between the PMBs with 3-10 mol% MPC units and poly(HEMA). Fibronectin adsorption on the polymer surface from a cell culture medium was determined by immunoassay. The adsorbed fibronection was evenly distrubuted in every polymer, however, the amount was reduced with an increase in the MPC unit composition in the PMB. This result suggested that the MPC unit could weaken the interaction between the polymer surface and proteins. When fibroblast L-929 cells, were cultured on the polymers, the cells adhered and the number of cells increased on not only the hydrophobic poly(BMA) but also on the hydrophilic poly(HEMA). However, the number of cells that adhered on the PMB surface decreased with an increase in the MPC unit composition. This was a result of the fibronectin adsorption behavior. Thus, it could be concluded that since the PMB could suppress cell adhesion proteins e.g. fibronectin, the PMB showed excellent cell adhesive resistance properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preparation of Phospholipid Polylners and Their Properties as Polymer Hydrogel Membranes
Ishihara, K., Ueda, T., & Nakabayashi, N. (1990) · Polymer Journal · doi:10.1295/polymj.22.355 · Cited by 1,078
Self-citationVariants of the cell recognition site of fibronectin that retain attachment-promoting activity.
Pierschbacher, M. D., & Ruoslahti, E. (1984) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.81.19.5985 · Cited by 681
Grinnell, F., & Feld, M. K. (1982) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)34609-x · Cited by 622
Interaction of cultured human endothelial cells with polymeric surfaces of different wettabilities
van Wachem, P. B., Beugeling, T., Feijen, J., Bantjes, A., Detmers, J. P., & van Aken, W. G. (1985) · Biomaterials · doi:10.1016/0142-9612(85)90101-2 · Cited by 591
Proteins at Interfaces II: Fundamentals and Applications
(1995) · ACS Symposium Series · doi:10.1021/bk-1995-0602 · Cited by 555
Protein adsorption from human plasma is reduced on phospholipid polymers
Ishihara, K., Ziats, N. P., Tierney, B. P., Nakabayashi, N., & Anderson, J. M. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820251107 · Cited by 471
Self-citationHemocompatibility of human whole blood on polymers with a phospholipid polar group and its mechanism
Ishihara, K., Oshida, H., Endo, Y., Ueda, T., Watanabe, A., & Nakabayashi, N. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820261202 · Cited by 435
Self-citationReduced thrombogenicity of polymers having phospholipid polar groups
Ishihara, K., Aragaki, R., Ueda, T., Watenabe, A., & Nakabayashi, N. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240809 · Cited by 394
Self-citationMori, T., Okumura, M., Matsuura, M., Ueno, K., Tokura, S., Okamoto, Y., Minami, S., & Fujinaga, T. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00017-3 · Cited by 353
Biomedical Applications of Polymeric Materials
鶴田, 禎., Kataoka, K., & Hayashi, T. (1993) · CRC Press eBooks · Cited by 328
Cited by
Surface hydration: Principles and applications toward low-fouling/nonfouling biomaterials
Chen, S., Li, L., Zhao, C., & Zheng, J. (2010) · Polymer · doi:10.1016/j.polymer.2010.08.022 · Cited by 1,677
Peptide-based biopolymers in biomedicine and biotechnology
Chow, D., Nunalee, M. L., Lim, D. W., Simnick, A. J., & Chilkoti, A. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2008.04.004 · Cited by 327
Minami, K., Okuno, M., Miyawaki, K., Okumachi, A., Ishizaki, K., Oyama, K., Kawaguchi, M., Ishizuka, N., Iwanaga, T., & Seino, S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507567102 · Cited by 261
Revolutionary advances in 2‐methacryloyloxyethyl phosphorylcholine polymers as biomaterials
Ishihara, K. (2019) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36635 · Cited by 230
Self-citationBrash, J. L. (2000) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856200744237 · Cited by 201
Brushing up functional materials
Ma, S., Zhang, X., Yu, B., & Zhou, F. (2019) · NPG Asia Materials · doi:10.1038/s41427-019-0121-2 · Cited by 199
Bioinspired phospholipid polymer biomaterials for making high performance artificial organs
Ishihara, K. (2000) · Science and Technology of Advanced Materials · doi:10.1016/s1468-6996(00)00012-7 · Cited by 192
Self-citationStructure of Water Incorporated in Sulfobetaine Polymer Films as Studied by ATR‐FTIR
Kitano, H., Mori, T., Takeuchi, Y., Tada, S., Gemmei‐Ide, M., Yokoyama, Y., & Tanaka, M. (2005) · Macromolecular Bioscience · doi:10.1002/mabi.200400212 · Cited by 170
Soft contact lens biomaterials from bioinspired phospholipid polymers
Goda, T., & Ishihara, K. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.2.167 · Cited by 163
Self-citationZhao, C., Li, L., & Zheng, J. (2010) · Langmuir · doi:10.1021/la103382j · Cited by 100
Metadata
- Authors
- Ishihara, K., Ishikawa, E., Iwasaki, Y., & Nakabayashi, N.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 10
- Issue
- 10
- Pages
- 1047-1061
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W2004709778
- Cited by
- 164
- References
- 23
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.