Validation of different techniques for the diagnosis of ventilator-associated pneumonia. Comparison with immediate postmortem pulmonary biopsy.
The DOI matches its Crossref record.
Abstract
To assess the accuracy of clinical parameters for the diagnosis of ventilator-associated (VA) pneumonia, as well as the diagnostic value of several invasive techniques, such as protected specimen brush (PSB), bronchoalveolar lavage (BAL), fiberoptic bronchial aspirates (FBAS), and percutaneous lung needle aspiration (PLNA), we compared the results of these techniques with the histopathology of immediate postmortem pulmonary biopsies, considered the "gold standard" reference test. We studied 30 mechanically ventilated patients (age 52 +/- 21 yr; mechanical ventilation period 9 +/- 7 days) who died in an intensive care unit. All patients received prior antibiotic treatment. The following procedures were performed immediately after death: bilateral PSB, BAL, FBAS, and PLNA, as well as bilateral minithoracotomies to obtain pulmonary biopsies as close as possible to the area sampled with the other techniques. According to the histopathology 18 patients had pneumonia and 12 did not. The presence of fever (sensitivity 55%, specificity 58%), purulent secretions (sensitivity 83%, specificity 33%), and chest radiograph infiltrates (sensitivity 78%, specificity 42%) could not differentiate in all instances presence from absence of pneumonia. Quantitative bacterial cultures of lung biopsies using 10(3) cfu/g as a cutoff point had low sensitivity (40%) and low specificity (45%) and could not differentiate the histologic absence or presence of pneumonia. Considering the histopathology of pulmonary biopsies as a gold standard, we found the following sensitivities for PSB, BAL, FBAS, and PLNA: 36, 50, 44, and 25%. The specificities were 50, 45, 48, and 79%, respectively. The sensitivities and specificities of different invasive techniques are much lower than those reported in clinical studies.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kalil, A. C., Metersky, M. L., Klompas, M., Muscedere, J., Sweeney, D. A., Palmer, L. B., Napolitano, L. M., O'Grady, N. P., Bartlett, J. G., Carratalà, J., et al. (2016) · Clinical Infectious Diseases · doi:10.1093/cid/ciw353 · Cited by 3,892
Ventilator-associated Pneumonia
Chastre, J., & Fagon, J.-Y. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.7.2105078 · Cited by 2,812
Khaw, K.-T., Wareham, N., Bingham, S., Luben, R., Welch, A., & Day, N. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-141-6-200409210-00006 · Cited by 974
“3) – – 2 (3) Extrapulmonary Sepsis syndrome 125 (44) 194 (43) 1 (6) 2 (3) Shock 18 (6) 77 (17) 6 (35) 20 (33) Pancreatitis 18 (6) 9 (2) – – Several transfusions of blood products 10 (3) 14 (3) 1 (6) 1 (2) Other 7 (2) 9 (2) – –”
BackgroundMethodResultInfluentialDu Rand, I. A., Blaikley, J., Booton, R., Chaudhuri, N., Gupta, V, Khalid, S., Mandal, S., Martin, J., Mills, J., Navani, N., et al. (2013) · Thorax · doi:10.1136/thoraxjnl-2013-203618 · Cited by 920
Fagon, J.-Y., Chastre, J., Wolff, M., Gervais, C., Parer-Aubas, S., Stéphan, F., Similowski, T., Mercat, A., Diehl, J.-L., Sollet, J.-P., et al. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-132-8-200004180-00004 · Cited by 854
HEYLAND, D. K., COOK, D. J., GRIFFITH, L., KEENAN, S. P., & BRUN-BUISSON, C. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9807050 · Cited by 827
The Acute Respiratory Distress Syndrome
Kollef, M. H., & Schuster, D. P. (1995) · New England Journal of Medicine · doi:10.1056/nejm199501053320106 · Cited by 550
Fabregas, N., Ewig, S., Torres, A., El-Ebiary, M., Ramirez, J., de la Bellacasa, J. P., Bauer, T., & Cabello, H. (1999) · Thorax · doi:10.1136/thx.54.10.867 · Cited by 487
Self-citationVentilator-Associated Pneumonia
(2012) · SpringerReference · doi:10.1007/springerreference_225126 · Cited by 406
The Effect of Late-Onset Ventilator-Associated Pneumonia in Determining Patient Mortality
Kollef, M. H., Silver, P., Murphy, D. M., & Trovillion, E. (1995) · Chest · doi:10.1378/chest.108.6.1655 · Cited by 402
SANCHEZ-NIETO, J. M., TORRES, A., GARCIA-CORDOBA, F., EL-EBIARY, M., CARRILLO, A., RUIZ, J., NUÑEZ, M. L., & NIEDERMAN, M. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.2.97-02039 · Cited by 344
Self-citationRUIZ, M., TORRES, A., EWIG, S., MARCOS, M. A., ALCÓN, A., LLEDÓ, R., ASENJO, M. A., & MALDONALDO, A. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9907090 · Cited by 340
Self-citationMembers of the Task Force:, Bouza, E., Brun-Buisson, C., Chastre, J., Ewig, S., Fagon, J.-Y., Marquette, C. H., Muñoz, P., Niederman, M. S., Papazian, L., et al. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.17510340 · Cited by 335
Marquette, C. H., Copin, M. C., Wallet, F., Neviere, R., Saulnier, F., Mathieu, D., Durocher, A., Ramon, P., & Tonnel, A. B. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.151.6.7767535 · Cited by 334
Does This Patient Have Ventilator-Associated Pneumonia?
Klompas, M. (2007) · JAMA · doi:10.1001/jama.297.14.1583 · Cited by 304
Comparison of Clinical Criteria for the Acute Respiratory Distress Syndrome with Autopsy Findings
Esteban, A., Fernández-Segoviano, P., Frutos-Vivar, F., Aramburu, J. A., Nájera, L., Ferguson, N. D., Alía, I., Gordo, F., & Ríos, F. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-141-6-200409210-00009 · Cited by 285
Ibrahim, E. H., Ward, S., Sherman, G., & Kollef, M. H. (2000) · Chest · doi:10.1378/chest.117.5.1434 · Cited by 284
EL-EBIARY, M., TORRES, A., FÁBREGAS, N., de la BELLACASA, J. P., GONZÁLEZ, J., RAMIREZ, J., del BAÑO, D., HERNÁNDEZ, C., & JIMÉNEZ de ANTA, M. T. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.2.9612023 · Cited by 271
Diagnosis of ventilator-associated pneumonia: a systematic review of the literature
Rea-Neto, A., Youssef, N. C. M., Tuche, F., Brunkhorst, F., Ranieri, V. M., Reinhart, K., & Sakr, Y. (2008) · Critical Care · doi:10.1186/cc6877 · Cited by 266
The Diagnosis of Ventilator-Associated Pneumonia
Kirtland, S. H., Corley, D. E., Winterbauer, R. H., Springmeyer, S. C., Casey, K. R., Hampson, N. B., & Dreis, D. F. (1997) · Chest · doi:10.1378/chest.112.2.445 · Cited by 254
Metadata
- Authors
- Torres, A., el-Ebiary, M., Padró, L., Gonzalez, J., de la Bellacasa, J. P., Ramirez, J., Xaubet, A., Ferrer, M., & Rodriguez-Roisin, R.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-02
- Volume
- 149
- Issue
- 2
- Pages
- 324-331
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2029267149
- Cited by
- 303
- References
- 0
- FWCI
- 18.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.