Twitch potentiation following voluntary diaphragmatic contraction.
The DOI matches its Crossref record.
Abstract
The purpose of this study was to determine whether twitch potentiation (a transient augmentation of twitch tension following vigorous muscular contraction) occurs in the human diaphragm in vivo. Six healthy subjects were studied. To determine whether twitch potentiation occurs, the subjects attempted to maximally activate their diaphragm by performing the combined Mueller-expulsive maneuver with visual feedback (Pdi max maneuver). Twitches were obtained before, at 10 s after the transdiaphragmatic pressure (Pdi) maneuver, and at intervals over the ensuing 10 min. We also determined whether twitch potentiation would occur following submaximal voluntary diaphragmatic contractions (33 and 66% of Pdi max). In addition, we examined whether repeated voluntary contractions would result in greater twitch potentiation compared with that observed after a single voluntary contraction. Twitch potentiation was observed in every subject. The number of maximal voluntary contractions (MVC) (one, two, or four) had no significant effect on the degree of twitch potentiation. The increase in twitch amplitude (expressed as a percentage of the control value) averaged 63 +/- 35% (SD)(pooled data from one, two, and four contraction trials). Twitch potentiation decayed in a monoexponential fashion (r = 0.99) with a time constant of 125 s (95% Cl = 100 to 160 s). Twitch potentiation was also observed after submaximal voluntary diaphragmatic contractions. Again, the number of voluntary contractions (one or four) had no significant effect on the degree of twitch potentiation. After submaximal diaphragmatic contractions of 66% of Pdi max, the degree of twitch potentiation was not significantly different, 61 +/- 36% (pooled data from one and four contraction trials) from that observed following the maximal voluntary contraction maneuvers.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Is Weaning Failure Caused by Low-Frequency Fatigue of the Diaphragm?
Laghi, F., Cattapan, S. E., Jubran, A., Parthasarathy, S., Warshawsky, P., Choi, Y.-S. A., & Tobin, M. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200210-1246oc · Cited by 359
Exercise-induced respiratory muscle fatigue: implications for performance
Romer, L. M., & Polkey, M. I. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01157.2007 · Cited by 352
Measurement of respiratory muscle strength.
Polkey, M. I., Green, M., & Moxham, J. (1995) · Thorax · doi:10.1136/thx.50.11.1131 · Cited by 251
Bilateral magnetic stimulation of the phrenic nerves from an anterolateral approach.
Mills, G. H., Kyroussis, D., Hamnegard, C. H., Polkey, M. I., Green, M., & Moxham, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.4.8887614 · Cited by 183
Endurance and Strength Training in Patients With COPD
Mador, M. J., Bozkanat, E., Aggarwal, A., Shaffer, M., & Kufel, T. J. (2004) · Chest · doi:10.1378/chest.125.6.2036 · Cited by 174
Self-citationComparison of electrical and magnetic stimulations to assess quadriceps muscle function
Verges, S., Maffiuletti, N. A., Kerherve, H., Decorte, N., Wuyam, B., & Millet, G. Y. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01051.2007 · Cited by 168
JEFFERY MADOR, M., KUFEL, T. J., PINEDA, L. A., & SHARMA, G. K. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.1.9903010 · Cited by 133
Self-citation
Metadata
- Authors
- Mador, M. J., Magalang, U. J., & Kufel, T. J.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-03
- Volume
- 149
- Issue
- 3
- Pages
- 739-743
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2169447486
- Cited by
- 98
- References
- 0
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.