Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 210

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Efficacy of a Herbst mandibular advancement device in obstructive sleep apnea.

Eveloff, S E, Rosenberg, C L, Carlisle, C C, Millman, R P·1994·American Journal of Respiratory and Critical Care Medicine

Abstract

Treatment options for obstructive sleep apnea (OSA) may involve potential side effects or discomfort; nasal continuous positive airway pressure (CPAP) may not be tolerated by 25% of patients. We therefore sought to determine the efficacy of mandibular advancement as a treatment for OSA, and to investigate whether clinical and radiographic parameters can predict the response to this treatment. Sixteen male and 3 female subjects with documented OSA who had failed or been unable to tolerate nasal CPAP underwent baseline polysomnography and cephalometry, and were then fitted with a removable Herbst appliance to achieve forward mandibular advancement during sleep. All subjects then underwent a second cephalometric evaluation and polysomnography with the appliance in place. Fourteen of 15 subjects demonstrated significant improvement in the degree of OSA, based on the apnea-hypopnia index (AHI) (34.7 +/- 5.3 to 12.9 +/- 2.4 events/h, p < 0.002). Comparison of pre- and posttreatment cephalometric values revealed no significant change in the posterior airway space (PAS) despite a reduction in mean AHI. There was a significant decrease in the mandible-hyoid distance (MP-H) with treatment for the group as a whole. When the study population was evaluated on the basis of a successful response to mandibular advancement (posttreatment AHI < 10), the baseline MP-H was found to be significantly shorter in the responders than in nonresponders. MP-H after mandibular advancement was likewise shorter in responders than in nonresponders. In addition, the soft palate length (PNS-P) showed a significantly greater shortening in responders after treatment.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.149.4.8143054

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 210

Metadata

Authors
Eveloff, S. E., Rosenberg, C. L., Carlisle, C. C., & Millman, R. P.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1994-04
Volume
149
Issue
4
Pages
905-909
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2162856105
Cited by
210
References
1
FWCI
3.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy of a Herbst mandibular advancement device in obstructive sleep apnea. https://app.cochat.ai/papers/10.1164/ajrccm.149.4.8143054
The paper
Eveloff, S. E., Rosenberg, C. L., Carlisle, C. C., & Millman, R. P. (1994). Efficacy of a Herbst mandibular advancement device in obstructive sleep apnea. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.149.4.8143054

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.