The DOI matches its Crossref record.
CO2 rebreathing during BiPAP ventilatory assistance.
Abstract
BiPAP ventilatory assistance can increase minute ventilation and reduce respiratory effort, but does not always reduce PaCO2. We studied the effects of BiPAP ventilatory assistance on PaCO2 and examined specific mechanisms whereby BiPAP ventilatory assistance may not lower PaCO2. BiPAP ventilatory assistance using a non-rebreather valve and volume cycled ventilation at similar settings produced significantly lower PaCO2 than BiPAP ventilatory assistance using a standard exhalation device. The failure of PaCO2 to fall with the standard exhalation device was due to exhalation past the exhalation device into the ventilator tubing, subsequent rebreathing of the exhaled gases, and an increase in dead space ventilation. Use of other fixed-resistance exhalation devices also resulted in exhalation back into the ventilator tubing. Use of a new plateau exhalation device or a non-rebreather valve eliminated CO2 rebreathing and its effect on dead space ventilation. Changing exhalation devices had no significant effect on BiPAP pressure generation or sensing capabilities. Our results indicate that the use of a standard exhalation device during BiPAP ventilatory assistance causes CO2 rebreathing, which can blunt any effect of BiPAP on PaCO2. Use of an appropriate alternative exhalation device can eliminate this problem.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Non-invasive ventilation in acute respiratory failure
(2002) · Thorax · doi:10.1136/thorax.57.3.192 · Cited by 652
Pulmonary Complications of Obesity
Koenig, S. M. (2001) · The American Journal of the Medical Sciences · doi:10.1097/00000441-200104000-00006 · Cited by 530
Clini, E., Sturani, C., Rossi, A., Viaggi, S., Corrado, A., Donner, C. F., & Ambrosino, N. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.02162001 · Cited by 447
BTS/ICS guideline for the ventilatory management of acute hypercapnic respiratory failure in adults
Davidson, A. C., Banham, S., Elliott, M., Kennedy, D., Gelder, C., Glossop, A., Church, A. C., Creagh-Brown, B., Dodd, J. W., Felton, T., et al. (2016) · Thorax · doi:10.1136/thoraxjnl-2015-208209 · Cited by 426
Navalesi, P., Fanfulla, F., Frigerio, P., Gregoretti, C., & Nava, S. (2000) · Critical Care Medicine · doi:10.1097/00003246-200006000-00015 · Cited by 316
Metadata
- Authors
- Ferguson, G. T., & Gilmartin, M.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1995-04
- Volume
- 151
- Issue
- 4
- Pages
- 1126-1135
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2150708384
- Cited by
- 188
- References
- 0
- FWCI
- 9.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CO2 rebreathing during BiPAP ventilatory assistance. https://app.cochat.ai/papers/10.1164/ajrccm.151.4.7697242
- The paper
- Ferguson, G. T., & Gilmartin, M. (1995). CO2 rebreathing during BiPAP ventilatory assistance. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.151.4.7697242
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.