Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 327

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Titration of tidal volume and induced hypercapnia in acute respiratory distress syndrome.

Roupie, E, Dambrosio, M, Servillo, G, Mentec, H, el Atrous, S, Beydon, L, Brun-Buisson, C, Lemaire, F, Brochard, L·1995·American Journal of Respiratory and Critical Care Medicine

Abstract

Mechanical ventilation may promote overdistension-induced pulmonary lesions in patients with acute respiratory distress syndrome (ARDS). The static pressure-volume (P-V) curve of the respiratory system can be used to determine the lung volume and corresponding static airway pressure at which lung compliance begins to diminish (the upper inflection point, or UIP). This fall in compliance may indicate overdistension of lung units. We prospectively studied 42 patients receiving mechanical ventilation with an FIO2 of 0.5 or more for at least 24 h. According to the Lung Injury Score (LIS), 25 patients were classified as having ARDS (LIS > 2.5), while 17 patients constituted a non-ARDS control group. The P-V curve was obtained every 2 d. Mechanical ventilation initially used standard settings (volume-control mode, a positive end-expiratory pressure [PEEP] adjusted to the lower inflection point on the P-V curve, and a tidal volume [VT] of 10 ml/kg). The end-inspiratory plateau pressure (Pplat) was compared to the UIP, and VT was lowered when the Pplat was above the UIP. In the range of lung volume studied on the P-V curves (up to 1600 ml), a UIP could be shown in only one control patient (at 23 cm H2O). By contrast, a UIP was present on the P-V curve obtained from all patients with ARDS, corresponding to a mean airway pressure of 26 +/- 6 cm H2O, a lung volume of 850 +/- 200 ml above functional residual capacity and 610 +/- 235 ml above PEEP.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.152.1.7599810

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 327

Metadata

Authors
Roupie, E., Dambrosio, M., Servillo, G., Mentec, H., el Atrous, S., Beydon, L., Brun-Buisson, C., Lemaire, F., & Brochard, L.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1995-07
Volume
152
Issue
1
Pages
121-128
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W1984842364
Cited by
327
References
24
FWCI
24.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Titration of tidal volume and induced hypercapnia in acute respiratory distress syndrome. https://app.cochat.ai/papers/10.1164/ajrccm.152.1.7599810
The paper
Roupie, E., Dambrosio, M., Servillo, G., Mentec, H., el Atrous, S., Beydon, L., Brun-Buisson, C., Lemaire, F., & Brochard, L. (1995). Titration of tidal volume and induced hypercapnia in acute respiratory distress syndrome. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.152.1.7599810

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.