The DOI matches its Crossref record.
Etiology of extubation failure and the predictive value of the rapid shallow breathing index.
Abstract
Failure of weaning from mechanical ventilation is thought to result from an imbalance between respiratory muscle capacity and respiratory demand. The ratio of respiratory rate to tidal volume (f/VT, rapid shallow breathing index) during spontaneous unsupported respiration increases when this imbalance exists, and may predict the success or failure of weaning from mechanical ventilation. Using f/VT, Yang and Tobin demonstrated a positive predictive value (PPV) of 0.78 (f/VT < or = 105 and weaning success) (1). To define the etiology of the 20% false-positive rate (FPR, f/VT < or = 105 and weaning failure), 94 patients who had an f/VT determined prior to extubation were studied prospectively. Of 84 patients with an f/VT < 100, 14 required reintubation within 72 h of extubation (FPR = 0.17, PPV = 0.83). Extubation in 13 of these 14 cases failed because of congestive heart failure, upper airway obstruction, aspiration, encephalopathy, or the development of a new pulmonary process. Only one patient needed reintubation solely because of the original respiratory process. Of 10 patients extubated with an f/VT > or = 100, four required reintubation, all because of the underlying respiratory process. This study confirms the high PPV for an f/VT < 100. The FPR of approximately 0.20 is best explained by extubation failure caused by processes for which f/VT is physiologically or temporally unlikely to predict success or failure. The negative predictive value (f/VT > or = 100 but extubation success) for f/VT may be lower than previously reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ely, E. W., Baker, A. M., Dunagan, D. P., Burke, H. L., Smith, A. C., Kelly, P. T., Johnson, M. M., Browder, R. W., Bowton, D. L., & Haponik, E. F. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612193352502 · Cited by 1,346
Evidence-Based Guidelines for Weaning and Discontinuing Ventilatory Support
MacIntyre, N. R. (2001) · Chest · doi:10.1378/chest.120.6_suppl.375s · Cited by 1,240
VALLVERDÚ, I., CALAF, N., SUBIRANA, M., NET, A., BENITO, S., & MANCEBO, J. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.6.9712135 · Cited by 480
Predictors of Successful Extubation in Neurosurgical Patients
NAMEN, A. M., WESLEY ELY, E., TATTER, S. B., DOUGLAS CASE, L., LUCIA, M. A., SMITH, A., LANDRY, S., WILSON, J. A., GLAZIER, S. S., BRANCH, C. L., et al. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2003060 · Cited by 355
Diaphragm ultrasound as a new index of discontinuation from mechanical ventilation
Ferrari, G., De Filippi, G., Elia, F., Panero, F., Volpicelli, G., & Aprà, F. (2014) · Critical Ultrasound Journal · doi:10.1186/2036-7902-6-8 · Cited by 306
Metadata
- Authors
- Epstein, S. K.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1995-08
- Volume
- 152
- Issue
- 2
- Pages
- 545-549
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2108954387
- Cited by
- 252
- References
- 0
- FWCI
- 9.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Etiology of extubation failure and the predictive value of the rapid shallow breathing index. https://app.cochat.ai/papers/10.1164/ajrccm.152.2.7633705
- The paper
- Epstein, S. K. (1995). Etiology of extubation failure and the predictive value of the rapid shallow breathing index. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.152.2.7633705
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.