Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 306

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Diaphragm ultrasound as a new index of discontinuation from mechanical ventilation

Open access
Ferrari, Giovanni, De Filippi, Giovanna, Elia, Fabrizio, Panero, Francesco, Volpicelli, Giovanni, Aprà, Franco·2014·Critical Ultrasound Journal

Abstract

BACKGROUND: Predictive indexes of weaning from mechanical ventilation are often inaccurate. Among the many indexes used in clinical practice, the rapid shallow breathing index is one of the most accurate. We evaluated a new weaning index consisting in the diaphragm thickening fraction (DTF) assessed by ultrasound. METHODS: Forty-six patients were prospectively enrolled. All patients were ventilated in pressure support through a tracheostomy tube. Patients underwent a spontaneous breathing trial (SBT) when they met all the following criteria: FiO2 < 0.5, PEEP ≤5 cmH2O, PaO2/FiO2 > 200, respiratory rate <30 breaths per minute, absence of fever, alert and cooperative, and hemodynamic stability without vaso-active therapy support. During the trial, the right hemi-diaphragm was visualized in the zone of apposition using a 10-MHz linear ultrasound probe. The patient was then instructed to perform breathing to total lung capacity (TLC) and then exhaling to residual volume (RV). Diaphragm thickness was recorded at TLC and RV, and the DTF was calculated as percentage from the following formula: Thickness at end inspiration - Thickness at end expiration / Thickness at end expiration. Also, the rapid shallow breathing index (RSBI) was calculated. Weaning failure was defined as the inability to maintain spontaneous breathing for at least 48 h, without any form of ventilatory support. RESULTS: A significant difference between diaphragm thickness at TLC and RV was observed both in patients who succeeded SBT and patients who failed. DTF was significantly different between patients who failed and patients who succeeded SBT. A cutoff value of a DTF >36% was associated with a successful SBT with a sensitivity of 0.82, a specificity of 0.88, a positive predictive value (PPV) of 0.92, and a negative predictive value (NPV) of 0.75. By comparison, RSBI <105 had a sensitivity of 0.93, a specificity of 0.88, a PPV of 0.93, and a NPV of 0.88 for determining SBT success. CONCLUSIONS: This study shows that in our cohort of patients, the assessment of DTF by diaphragm ultrasound may perform similarly to other weaning indexes. If validated by other studies, this method may be used in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/2036-7902-6-8

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 306

Metadata

Authors
Ferrari, G., De Filippi, G., Elia, F., Panero, F., Volpicelli, G., & Aprà, F.
Venue
Critical Ultrasound Journal
Published
2014-06-07
Volume
6
Issue
1
Pages
8-8
ISSN
  • 2036-3176 (ISSN-L)
  • 2036-7902
OpenAlex
W2126880371
Cited by
306
References
19
FWCI
13.57
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diaphragm ultrasound as a new index of discontinuation from mechanical ventilation. https://app.cochat.ai/papers/10.1186/2036-7902-6-8
The paper
Ferrari, G., De Filippi, G., Elia, F., Panero, F., Volpicelli, G., & Aprà, F. (2014). Diaphragm ultrasound as a new index of discontinuation from mechanical ventilation. Critical Ultrasound Journal. https://doi.org/10.1186/2036-7902-6-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.