Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 272

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Effect of a nitric oxide synthase inhibitor and a glucocorticosteroid on exhaled nitric oxide.

Yates, D H, Kharitonov, S A, Robbins, R A, Thomas, P S, Barnes, P J · 1995 · American Journal of Respiratory and Critical Care Medicine

Abstract

Nitric oxide (NO) is produced by a variety of cells within the respiratory tract, including inflammatory epithelial cells. NO has been detected in the exhaled air of normal human subjects, and its concentration is raised in asthmatic patients. To study whether exhaled NO arises from the respiratory tract, we administered a NO synthase (NOS) inhibitor, NG-monomethyl-L-arginine (L-NMMA), by inhalation (490 mg) in a double-blind randomized manner in nine normal and six asthmatic subjects. Because exhaled NO may arise from an inducible isoform of NO synthase that may be inhibited by glucocorticosteroids, we also studied the effects of oral prednisolone (30 mg orally for 3 d) in seven normal and six asthmatic subjects in a separate double-blind crossover study with matched placebo. After nebulized L-NMMA, there was a significant fall in peak exhaled NO compared with saline control values, with a mean fall of 43.6 +/- 5.6% in normal subjects (p < 0.01) and of 39.7 +/- 6.5% (p < 0.01) in asthmatic subjects, which persisted for 4 h. There were no effects of L-NMMA inhalation on heart rate, blood pressure, or FEV1 in either normal or asthmatic patients. Administration of oral prednisolone (30 mg) resulted in a fall in exhaled NO concentrations in asthmatic subjects by 21.6 +/- 5.0% at 48 h (p < 0.01) but no significant change in normal subjects. These data suggest that NOS inhibitors may be safely given in normal and asthmatic patients and that the increased exhaled NO seen in asthmatic patients is likely to be caused by induction of inducible NOS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.152.3.7663801

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 272

Metadata

Authors
Yates, D. H., Kharitonov, S. A., Robbins, R. A., Thomas, P. S., & Barnes, P. J.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1995-09
Volume
152
Issue
3
Pages
892-896
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2073791786
Cited by
272
References
15
FWCI
10.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of a nitric oxide synthase inhibitor and a glucocorticosteroid on exhaled nitric oxide. https://app.cochat.ai/papers/10.1164/ajrccm.152.3.7663801
The paper
Yates, D. H., Kharitonov, S. A., Robbins, R. A., Thomas, P. S., & Barnes, P. J. (1995). Effect of a nitric oxide synthase inhibitor and a glucocorticosteroid on exhaled nitric oxide. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.152.3.7663801

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.