Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 177

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Efficacy of auto-CPAP in the treatment of obstructive sleep apnea/hypopnea syndrome.

Meurice, J C, Marc, I, Sériès, F · 1996 · American Journal of Respiratory and Critical Care Medicine

Abstract

The auto-CPAP (Morphée Plus) is characterized by its ability to modify the positive-pressure level applied during the night for the presence or absence of sleep-induced respiratory disorders. The aim of the study was to compare the efficacy of this new mode of CPAP therapy with that of conventional constant-CPAP in the treatment of sleep apnea/hypopnea syndrome (SAHS). Sixteen patients with SAHS were randomly allocated to two groups that were paired for age, apnea/hypopnea index, and mean sleep latency. In the auto-CPAP group, the pressure level could change within fixed limits in both directions (+2 to -4 cm H2O) of the previously determined effective pressure level (Peff). In the constant-CPAP group, patients used the same apparatus (Morphée Plus) in a constant mode at Peff level. At the beginning of the study, the Peff level was determined during a polysomnographic recording. Day-time vigilance was measured subjectively by a standardized questionnaire and objectively by the maintenance of wakefulness test (MWT); Trailmaking tests (TMT) were used to evaluate cognitive functions. After 3 wk of home CPAP therapy, a control sleep study was done with the CPAP machine used in the protocol, and daytime vigilance and cognitive function tests were obtained. Baseline sleep and nocturnal breathing disorders characteristics did not differ between the two groups, and daytime vigilance and cognitive function abnormalities were similarily altered. In both groups, the apnea/hypopnea index was within normal range at the final CPAP sleep study. In the auto-CPAP group, 49.3 +/- 14.9% (mean +/- SD) of home treatment time was spent at a pressure < or = Peff. Home amount of use estimated by the number of sleeping hours with a positive pressure applied was 6.5 +/- 1.0 h in the auto-CPAP group and 5.1 +/- 1.1 h in the constant-CPAP group (p = 0.02). During the control CPAP sleep study, the positive pressure level was significantly lower during Stage III-IV than during the other sleep stages (p = 0.004). The improvement in the MWT and the TMT observed with CPAP therapy was identical in both groups. We conclude that (1) the amount of use during CPAP treatment is higher with auto-CPAP than with constant-CPAP, and (2) Morphée+auto-CPAP is an efficient as conventional CPAP in correcting nocturnal breathing disorders, daytime sleepiness, and cognitive impairment in SAHS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.153.2.8564134

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 177

Metadata

Authors
Meurice, J. C., Marc, I., & Sériès, F.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1996-02
Volume
153
Issue
2
Pages
794-798
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2003372031
Cited by
177
References
4
FWCI
2.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy of auto-CPAP in the treatment of obstructive sleep apnea/hypopnea syndrome. https://app.cochat.ai/papers/10.1164/ajrccm.153.2.8564134
The paper
Meurice, J. C., Marc, I., & Sériès, F. (1996). Efficacy of auto-CPAP in the treatment of obstructive sleep apnea/hypopnea syndrome. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.153.2.8564134

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.