The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Elevated nitric oxide concentrations in isolated lower airway gas of asthmatic subjects.
Abstract
Previous studies have raised the possibility that the measurement of nitric oxide (NO.) concentrations in expired air may represent a noninvasive measure of lower airway inflammation. To address the question of whether the elevated NO. recovered in mixed expired air from asthmatic subjects is a reflection of the pulmonary airway microenvironment or merely nasopharyngeal contamination, mixed expired NO. determinations were performed in five normal and five asthmatic subjects before and after orotracheal intubation (thereby isolating the lower airway gas from ambient air contamination or gas conditioned in the nasopharynx). The mixed expired NO. concentrations determined in patients with asthma were significantly elevated (p < 0.05 or less) above those of normal subjects in both the pre- and postintubation samples. After intubation, mixed expired NO. levels were 4.7 +/- 1.3 ppb and 13.2 +/- 2.0 ppb in normal and asthmatic individuals, respectively; the difference in these values was statistically significant (p < 0.01). Lower airway gas, sampled through the bronchoscope during a breathhold, was found to contain NO. concentrations of 7.0 +/- 1.2 ppb and 40.5 +/- 5.6 ppb at the tracheal carina of normal and asthmatic individuals, respectively. The asthmatic values were significantly (p < 0.01) elevated above those found in normal subjects. These findings indicate that the difference in mixed expired NO. of normal subjects and asthmatics reflects a difference in NO. concentration present in the lower airway.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Endogenous nitric oxide is present in the exhaled air of rabbits, guinea pigs and humans
Gustafsson, L. E., Leone, A. M., Persson, M. G., Wiklund, N. P., & Moncada, S. (1991) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(91)91268-h · Cited by 964
The biology of nitrogen oxides in the airways
Gaston, B., Drazen, J. M., Loscalzo, J., & Stamler, J. S. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.2.7508323 · Cited by 918
Self-citation
Cited by
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Glucocorticoid resistance in inflammatory diseases
Barnes, P. J., & Adcock, I. M. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60326-3 · Cited by 983
Nitric oxide in health and disease of the respiratory system
Ricciardolo, F. L. M., Sterk, P. J., Gaston, B., & Folkerts, G. (2004) · Physiological Reviews · doi:10.1152/physrev.00034.2003 · Cited by 903
Exhaled Markers of Pulmonary Disease
KHARITONOV, S. A., & BARNES, P. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2009041 · Cited by 844
(1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.6.ats8-99 · Cited by 771
Metadata
- Authors
- Massaro, A. F., Mehta, S., Lilly, C. M., Kobzik, L., Reilly, J. J., & Drazen, J. M.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-05
- Volume
- 153
- Issue
- 5
- Pages
- 1510-1514
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2005870537
- Cited by
- 189
- References
- 2
- FWCI
- 13.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Elevated nitric oxide concentrations in isolated lower airway gas of asthmatic subjects. https://app.cochat.ai/papers/10.1164/ajrccm.153.5.8630594
- The paper
- Massaro, A. F., Mehta, S., Lilly, C. M., Kobzik, L., Reilly, J. J., & Drazen, J. M. (1996). Elevated nitric oxide concentrations in isolated lower airway gas of asthmatic subjects. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.153.5.8630594
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.