The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Ventilatory and hemodynamic effects of continuous positive airway pressure in left heart failure.
Abstract
The ventilatory and hemodynamic effects of continuous positive airway pressure (CPAP) delivered via a face mask (at 0, 5, and 10 cm H2O, and after a return to 0 cm H2O) were studied in nine patients with acute left heart failure (pulmonary artery occlusion pressure [PAOP] > or = 18 mm Hg, and cardiac index [CI] < or = 2.8 L/min/m2). CPAP at 10 cm H2O induced an improvement in lung compliance (60 +/- 10 ml/cm H2O to 87 +/- 20 ml/cm H2O, p < 0.05) and in lung and airway resistance (5.7 +/- 1.0 cm H2O/L/s to 3.4 +/- 1.0 cm H2O/L/s, p < 0.05), a reduction in work of breathing (18 +/- 3 J/min to 12 +/- 2 J/min, p < 0.05), and in the pressure-time index of the respiratory muscles (279 +/- 22 cm H2O/s/min to 174 +/- 25 cm H2O/s/min, p < 0.05), without significant changes in breathing pattern. Despite a significant reduction in the negative swings in intrathoracic pressure (15.2 +/- 1.9 cm H2O to 10.8 +/- 1.8 cm H2O, p < 0.001), no significant change was observed in CI or stroke volume during CPAP. However, mean transmural filling pressures decreased significantly with CPAP, suggesting a better cardiac performance. Neither the level of stroke volume nor of PAOP, was predictive of changes in CI or in stroke volume. In patients with respiratory insufficiency caused by congestive heart failure (CHF), CPAP reduces respiratory muscle effort without altering cardiac output. The slight decrease in mean transmural left and right atrial pressures suggests an improvement in cardiac performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of Intrathoracic Pressure on Left Ventricular Performance
Buda, A. J., Pinsky, M. R., Ingels, N. B., Daughters, G. T., Stinson, E. B., & Alderman, E. L. (1979) · New England Journal of Medicine · doi:10.1056/nejm197908303010901 · Cited by 823
Circulatory Physiology: Cardiac Output and Its Regulation
Guyton, A. C. (1965) · The American Journal of the Medical Sciences · doi:10.1097/00000441-196501000-00051 · Cited by 634
Brochard, L., Harf, A., Lorino, H., & Lemaire, F. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/139.2.513 · Cited by 630
Self-citationPetrof, B. J., Legaré, M., Goldberg, P., Milic-Emili, J., & Gottfried, S. B. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/141.2.281 · Cited by 486
Cardiac Output Response to Continuous Positive Airway Pressure in Congestive Heart Failure
Bradley, T. D., Holloway, R. M., McLaughlin, P. R., Ross, B. L., Walters, J., & Liu, P. P. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/145.2_pt_1.377 · Cited by 378
The oxygen cost of breathing in patients with cardiorespiratory disease.
Field, S. K., Kelly, S. M., & Macklem, P. T. (1982) · PubMed · doi:10.1164/arrd.1982.126.1.9 · Cited by 238
Sassoon, C. S. H., Light, R. W., Lodia, R., Sieck, G. C., & Mahutte, C. K. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.3.469 · Cited by 238
Cardiac performance in response to PEEP in patients with cardiac dysfunction
GRACE, M. P., & GREENBAUM, D. M. (1982) · Critical Care Medicine · doi:10.1097/00003246-198206000-00002 · Cited by 175
Effectiveness of CPAP by mask for pulmonary edema associated with hypercarbia
Perel, A., Williamson, D. C., & Modell, J. H. (1983) · Intensive Care Medicine · doi:10.1007/bf01693700 · Cited by 40
Effects of CPAP on Cardiac Output in Pigs With Pacing-Induced Congestive Heart Failure
Genovese, J. P., Huberfeld, S. I., Tarasiuk, A., Moskowitz, M., & Scharf, S. M. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.6.8520745 · Cited by 36
Cited by
Ventilator-induced Lung Injury: Lessons from Experimental Studies
DREYFUSS, D., & SAUMON, G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.9604014 · Cited by 2,297
Official ERS/ATS clinical practice guidelines: noninvasive ventilation for acute respiratory failure
Rochwerg, B., Brochard, L., Elliott, M. W., Hess, D., Hill, N. S., Nava, S., Navalesi, P., Antonelli, M., Brozek, J., Conti, G., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.02426-2016 · Cited by 1,668
Self-citationAdaptive Servo-Ventilation for Central Sleep Apnea in Systolic Heart Failure
Cowie, M. R., Woehrle, H., Wegscheider, K., Angermann, C., d’Ortho, M.-P., Erdmann, E., Levy, P., Simonds, A. K., Somers, V. K., Zannad, F., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1506459 · Cited by 1,107
Multiple System Organ Failure: Is Mechanical Ventilation a Contributing Factor?
SLUTSKY, A. S., & TREMBLAY, L. N. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.6.9709092 · Cited by 836
Noninvasive Ventilation in Acute Cardiogenic Pulmonary Edema
Gray, A., Goodacre, S., Newby, D. E., Masson, M., Sampson, F., & Nicholl, J. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0707992 · Cited by 699
Metadata
- Authors
- Lenique, F., Habis, M., Lofaso, F., Dubois-Randé, J. L., Harf, A., & Brochard, L.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-02
- Volume
- 155
- Issue
- 2
- Pages
- 500-505
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2171695607
- Cited by
- 331
- References
- 10
- FWCI
- 12.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ventilatory and hemodynamic effects of continuous positive airway pressure in left heart failure. https://app.cochat.ai/papers/10.1164/ajrccm.155.2.9032185
- The paper
- Lenique, F., Habis, M., Lofaso, F., Dubois-Randé, J. L., Harf, A., & Brochard, L. (1997). Ventilatory and hemodynamic effects of continuous positive airway pressure in left heart failure. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.155.2.9032185
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.