Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 199

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Reliability of Inspiratory Capacity for Estimating End-expiratory Lung Volume Changes during Exercise in Patients with Chronic Obstructive Pulmonary Disease

YAN, SHENG, KAMINSKI, DARIUSZ, SLIWINSKI, PAWEL·1997·American Journal of Respiratory and Critical Care Medicine

Abstract

The inspiratory capacity (IC) maneuver is increasingly used to monitor exercise-induced dynamic hyperinflation in patients with COPD. However, the reliability of this method in patients with COPD exercising to symptom limitation has not been systematically studied and presented. The purpose of the present study was therefore to evaluate the reliability of the IC maneuver in assessing changes in end-expiratory lung volume (EELV) by assessing the pressure developed during IC maneuvers, in patients with COPD during incremental bicycle exercise to exhaustion. Fifteen patients with stable COPD performed bicycle exercise to symptom limitation. During the experiment, the patients performed IC efforts during resting breathing and at the end of each exercise work load. Esophageal pressure (Pes) measured at peak inspired volume plateau (zero flow) was -13.5 +/- 1.9 and -13.4 +/- 1.9 cm H2O (p = 0.79) during IC maneuvers at resting breathing and during the final exercise work load, respectively. When the Pes values at the peak inspired volume plateau during IC efforts at each exercise level were expressed as a percentage of those during resting breathing, the great majority of the ratios were above 90% with the lowest at 84%, and these ratios were independent of exercise intensity. Despite a constant Pes during IC, there was a progressive decrease in IC with increasing exercise work load in most patients, suggesting an increase in EELV. At the highest exercise work load achieved, delta EELV calculated as the decrease in IC was 0.26 +/- 0.06 L (p < 0.001). We conclude that repeated IC maneuver is a simple and reliable method for estimating EELV changes during exercise to exhaustion in patients with COPD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.156.1.9608113

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 199

Metadata

Authors
YAN, S., KAMINSKI, D., & SLIWINSKI, P.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1997-07-01
Volume
156
Issue
1
Pages
55-59
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2083926687
Cited by
199
References
5
FWCI
4.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of Inspiratory Capacity for Estimating End-expiratory Lung Volume Changes during Exercise in Patients with Chronic Obstructive Pulmonary Disease. https://app.cochat.ai/papers/10.1164/ajrccm.156.1.9608113
The paper
YAN, S., KAMINSKI, D., & SLIWINSKI, P. (1997). Reliability of Inspiratory Capacity for Estimating End-expiratory Lung Volume Changes during Exercise in Patients with Chronic Obstructive Pulmonary Disease. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.156.1.9608113

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.