Reliability of Inspiratory Capacity for Estimating End-expiratory Lung Volume Changes during Exercise in Patients with Chronic Obstructive Pulmonary Disease
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The inspiratory capacity (IC) maneuver is increasingly used to monitor exercise-induced dynamic hyperinflation in patients with COPD. However, the reliability of this method in patients with COPD exercising to symptom limitation has not been systematically studied and presented. The purpose of the present study was therefore to evaluate the reliability of the IC maneuver in assessing changes in end-expiratory lung volume (EELV) by assessing the pressure developed during IC maneuvers, in patients with COPD during incremental bicycle exercise to exhaustion. Fifteen patients with stable COPD performed bicycle exercise to symptom limitation. During the experiment, the patients performed IC efforts during resting breathing and at the end of each exercise work load. Esophageal pressure (Pes) measured at peak inspired volume plateau (zero flow) was -13.5 +/- 1.9 and -13.4 +/- 1.9 cm H2O (p = 0.79) during IC maneuvers at resting breathing and during the final exercise work load, respectively. When the Pes values at the peak inspired volume plateau during IC efforts at each exercise level were expressed as a percentage of those during resting breathing, the great majority of the ratios were above 90% with the lowest at 84%, and these ratios were independent of exercise intensity. Despite a constant Pes during IC, there was a progressive decrease in IC with increasing exercise work load in most patients, suggesting an increase in EELV. At the highest exercise work load achieved, delta EELV calculated as the decrease in IC was 0.26 +/- 0.06 L (p < 0.001). We conclude that repeated IC maneuver is a simple and reliable method for estimating EELV changes during exercise to exhaustion in patients with COPD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O'Donnell, D. E., & Webb, K. A. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.5.1351 · Cited by 543
Contractile Properties of the Human Diaphragm during Chronic Hyperinflation
Similowski, T., Yan, S., Gauthier, A. P., Macklem, P. T., & Bellemare, F. (1991) · New England Journal of Medicine · doi:10.1056/nejm199109263251304 · Cited by 473 · cited 1×
“These results are consistent with the previous findings that ( 1 ) patients with stable COPD are able to nearly maximally activate their inspiratory muscles (diaphragm) during maximal inspiratory efforts ( 16 , 17), and ( 2 ) severe inspiratory muscle fatigue leading to detectable reduction in the ability to generate…”
ResultSelf-citationBelman, M. J., Botnick, W. C., & Shin, J. W. (1996) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.153.3.8630581 · Cited by 402
Pulmonary mechanics during exercise in subjects with chronic airflow obstruction
Stubbing, D. G., Pengelly, L. D., Morse, J. L., & Jones, N. L. (1980) · Journal of Applied Physiology · doi:10.1152/jappl.1980.49.3.511 · Cited by 314
Johnson, B. D., Reddan, W. G., Pegelow, D. F., Seow, K. C., & Dempsey, J. A. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.5_pt_1.960 · Cited by 168
O'donnell, D. E., Sanii, R., & Younes, M. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.6.1510 · Cited by 131
Lung volumes during low-intensity steady-state cycling
Babb, T. G., & Rodarte, J. R. (1991) · Journal of Applied Physiology · doi:10.1152/jappl.1991.70.2.934 · Cited by 26
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Dynamic Hyperinflation and Exercise Intolerance in Chronic Obstructive Pulmonary Disease
O'DONNELL, D. E., REVILL, S. M., & WEBB, K. A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.5.2012122 · Cited by 1,076
Outcomes for COPD pharmacological trials: from lung function to biomarkers
Cazzola, M., MacNee, W., Martinez, F. J., Rabe, K. F., Franciosi, L. G., Barnes, P. J., Brusasco, V., Burge, P. S., Calverley, P. M. A., Celli, B. R., et al. (2008) · European Respiratory Journal · doi:10.1183/09031936.00099306 · Cited by 858
Recommendations on the use of exercise testing in clinical practice
Palange, P., Ward, S. A., Carlsen, K.-H., Casaburi, R., Gallagher, C. G., Gosselink, R., O'Donnell, D. E., Puente-Maestu, L., Schols, A. M., Singh, S., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00046906 · Cited by 718
O'DONNELL, D. E., LAM, M., & WEBB, K. A. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.5.9804004 · Cited by 532
Use of exercise testing in the evaluation of interventional efficacy: an official ERS statement
Puente-Maestu, L., Palange, P., Casaburi, R., Laveneziana, P., Maltais, F., Neder, J. A., O'Donnell, D. E., Onorati, P., Porszasz, J., Rabinovich, R., et al. (2016) · European Respiratory Journal · doi:10.1183/13993003.00745-2015 · Cited by 412
MARIN, J. M., CARRIZO, S. J., GASCON, M., SANCHEZ, A., GALLEGO, B., & CELLI, B. R. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.6.2003172 · Cited by 388
Pathophysiology of Dyspnea in Chronic Obstructive Pulmonary Disease: A Roundtable
O'Donnell, D. E., Banzett, R. B., Carrieri-Kohlman, V., Casaburi, R., Davenport, P. W., Gandevia, S. C., Gelb, A. F., Mahler, D. A., & Webb, K. A. (2007) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200611-159cc · Cited by 380
Emerging Concepts in the Evaluation of Ventilatory Limitation During Exercise
Johnson, B. D., Weisman, I. M., Zeballos, R. J., & Beck, K. C. (1999) · Chest · doi:10.1378/chest.116.2.488 · Cited by 363
Somfay, A., Porszasz, J., Lee, S. M., & Casaburi, R. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.00082201 · Cited by 339
O'DONNELL, D. E., D'ARSIGNY, C., & WEBB, K. A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.4.2007026 · Cited by 332
“This has been found to be a reliable and responsive method of tracking acute changes in lung volume (10, 15, 16 ).”
MethodFlow limitation and dynamic hyperinflation: key concepts in modern respiratory physiology
Calverley, P. M. A., & Koulouris, N. G. (2005) · European Respiratory Journal · doi:10.1183/09031936.04.00113204 · Cited by 258
“These studies were made possible by the development of reliable methods of measuring IC during exercise [ 76 ], when TLC appears to be constant [77].”
MethodMechanisms of activity-related dyspnea in pulmonary diseases
O’Donnell, D. E., Ora, J., Webb, K. A., Laveneziana, P., & Jensen, D. (2009) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2009.01.010 · Cited by 235
The major limitation to exercise performance in COPD is dynamic hyperinflation
O'Donnell, D. E., & Webb, K. A. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90336.2008b · Cited by 221
Dyspnea and Activity Limitation in COPD: Mechanical Factors
O'Donnell, D. E., & Laveneziana, P. (2007) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550701480455 · Cited by 220
“(2, 27); (2) resting IC represents the operating limits for tidal volume (VT) expansion during the increased ventilation of exercise (3, 28); and (3) resting IC can predict the peak symptomlimited V’O2 in patients with expiratory flow-limitation at rest (3, 28, 29).”
BackgroundInspiratory Capacity during Exercise: Measurement, Analysis, and Interpretation
Guenette, J. A., Chin, R. C., Cory, J. M., Webb, K. A., & O'Donnell, D. E. (2013) · Pulmonary Medicine · doi:10.1155/2013/956081 · Cited by 203
“[26] determined the reliability of IC measurements in individuals with COPD during incremental cycle exercise by comparing esophageal pressure at peak inspired plateau volume during serial IC efforts.”
BackgroundMethodDiaphragm Activation during Exercise in Chronic Obstructive Pulmonary Disease
SINDERBY, C., SPAHIJA, J., BECK, J., KAMINSKI, D., YAN, S., COMTOIS, N., & SLIWINSKI, P. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2007033 · Cited by 201
Self-citationVentilatory and perceptual responses to cycle exercise in obese women
Ofir, D., Laveneziana, P., Webb, K. A., & O'Donnell, D. E. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00898.2006 · Cited by 176
Does dynamic hyperinflation contribute to dyspnoea during exercise in patients with COPD?
Guenette, J. A., Webb, K. A., & O’Donnell, D. E. (2012) · European Respiratory Journal · doi:10.1183/09031936.00157711 · Cited by 162
Vogiatzis, I. (2005) · Thorax · doi:10.1136/thx.2004.039115 · Cited by 121
Helium-Hyperoxia, Exercise, and Respiratory Mechanics in Chronic Obstructive Pulmonary Disease
Eves, N. D., Petersen, S. R., Haykowsky, M. J., Wong, E. Y., & Jones, R. L. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200509-1533oc · Cited by 120
“This technique has previously been shown to be reliable during exercise in this population ( 20 , 21).”
MethodReliability of ventilatory parameters during cycle ergometry in multicentre trials in COPD
O’Donnell, D. E., Travers, J., Webb, K. A., He, Z., Lam, Y.-M., Hamilton, A., Kesten, S., Maltais, F., & Magnussen, H. (2009) · European Respiratory Journal · doi:10.1183/09031936.00168708 · Cited by 113
Sex differences in the perceived intensity of breathlessness during exercise with advancing age
Ofir, D., Laveneziana, P., Webb, K. A., Lam, Y.-M., & O'Donnell, D. E. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00079.2008 · Cited by 87
Factors Limiting Exercise Tolerance in Chronic Lung Diseases
Vogiatzis, I., & Zakynthinos, S. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c110015 · Cited by 77
“, the product of compliance and resistance) of the respiratory system, the inspired tidal volume, and the expiratory time available (24, 79, 81, 108, 131, 199, 211, 226, 228, 236, 237, 251, 252, 295, 340, 343).”
Puente-Maestu, L., Abad, Y. M., Pedraza, F., Sánchez, G., & Stringer, W. W. (2006) · Lung · doi:10.1007/s00408-005-2576-x · Cited by 45
“maximally [9, 36].”
Ventilatory constraints and dyspnea during exercise in chronic obstructive pulmonary disease
Laveneziana, P., Parker, C. M., & O’Donnell, D. E. (2007) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h07-119 · Cited by 39
Metadata
- Authors
- YAN, S., KAMINSKI, D., & SLIWINSKI, P.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-07-01
- Volume
- 156
- Issue
- 1
- Pages
- 55-59
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2083926687
- Cited by
- 199
- References
- 7
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.