The DOI matches its Crossref record.
Inhaled Bronchodilator Therapy in Mechanically Ventilated Patients
Abstract
Therapeutic aerosols are commonly used in mechanically ventilated patients, mainly to deliver bronchodilator drugs. Because ventilator-supported patients often receive several different classes of medications parenterally, the inhaled route of administration is particularly useful as an alternate route for drug delivery. Both nebulizers and metered-dose inhalers (MDIs) can be adapted for use in ventilator circuits. Traditionally, nebulizers have been used to deliver bronchodilators, antibiotics, and surfactant in mechanically ventilated patients, whereas MDIs chiefly have been used to deliver beta-adrenergic and anticholinergic bronchodilators (1). In the past, the combination of an MDI with an elbow adapter was considered to be ineffective (2) due to aerosol impaction in the ventilator circuit and endotracheal tube (3). However, recent studies (4‐6) have clearly established the efficacy of MDIs for delivering bronchodilators in mechanically ventilated patients, with the caveat that the technique needs to be carefully executed. With a better understanding of the many factors influencing aerosol delivery and deposition in mechanically ventilated patients, it is possible to provide a scientific basis for inhaled bronchodilator therapy in these patients. FACTORS INFLUENCING LOWER RESPIRATORY TRACT DEPOSITION OF AEROSOL In mechanically ventilated patients, the efficiency of aerosol delivery to the lower respiratory tract depends on several factors that are not concerns in ambulatory patients (7). Important determinants of aerosol deposition in ventilator-supported patients include the delivery system, particle size, characteristics of the ventilator circuit, ventilator mode, and patient-related factors. The effect of each factor on aerosol delivery is difficult to elucidate because of the large number of variables involved. Therefore, several investigators have conducted in vitro studies to define each variable’s influence on aerosol delivery with mechanical ventilators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Device Selection and Outcomes of Aerosol Therapy: Evidence-Based Guidelines
Dolovich, M. B., Ahrens, R. C., Hess, D. R., Anderson, P., Dhand, R., Rau, J. L., Smaldone, G. C., & Guyatt, G. (2005) · Chest · doi:10.1378/chest.127.1.335 · Cited by 794
Self-citationRodrigo, G. J., Rodrigo, C., & Hall, J. B. (2004) · Chest · doi:10.1378/chest.125.3.1081 · Cited by 290
RISK FACTORS FOR NOSOCOMIAL PNEUMONIA
Fleming, C. A., Balaguera, H. U., & Craven, D. E. (2001) · Medical Clinics of North America · doi:10.1016/s0025-7125(05)70395-3 · Cited by 46
Metadata
- Authors
- DHAND, R., & TOBIN, M. J.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-07-01
- Volume
- 156
- Issue
- 1
- Pages
- 3-10
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2122744323
- Cited by
- 215
- References
- 0
- FWCI
- 10.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inhaled Bronchodilator Therapy in Mechanically Ventilated Patients. https://app.cochat.ai/papers/10.1164/ajrccm.156.1.9610025
- The paper
- DHAND, R., & TOBIN, M. J. (1997). Inhaled Bronchodilator Therapy in Mechanically Ventilated Patients. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.156.1.9610025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.