CoChat

Measurements of Exhaled Nitric Oxide with the Single-Breath Technique and Positive Expiratory Pressure in Infants

WILDHABER, JOHANNES H., HALL, GRAHAM L., STICK, STEPHEN M. · 1999 · American Journal of Respiratory and Critical Care Medicine
Cited by 81

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The aim of this study was to adapt the single-breath technique with positive expiratory pressure to measure exhaled nitric oxide (eNO) in infants. We hypothesized that exhaled eNO was greater in wheezy than in healthy infants. We studied 30 infants (16 wheezy and 14 healthy). The forced expiratory volume in 0.5 s (FEV0.5) was determined with the raised volume rapid thoracic compression technique, and eNO was measured during constant expiratory flow with a rapid-response chemiluminescence analyzer. After passive inflation to a preset pressure of 20 cm H2O, thoracic compression with an inflatable jacket caused forced expiration to occur through a face-mask with an expiratory flow resistor attached. During the forced expiration, the jacket pressure was increased to maintain a constant driving mouth pressure and hence a constant expiratory flow (50 ml/s). The mean level of eNO in the wheezy infants (31.8 ppb) was significantly higher than the level in healthy infants (18.8 ppb) (p = 0.03). A family history of atopy in parents was associated with increased eNO levels (p < 0.001) independent of age, sex, weight, length, wheezing, and FEV0.5. We conclude that the single-breath technique with positive expiratory pressure is a feasible method for measuring eNO in infants. Levels of eNO were significantly higher in wheezy infants and in those with a family history of atopy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.159.1.9805021

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 81

Metadata

Authors
WILDHABER, J. H., HALL, G. L., & STICK, S. M.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1999-01-01
Volume
159
Issue
1
Pages
74-78
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2144568609
Cited by
81
References
1
FWCI
2.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurements of Exhaled Nitric Oxide with the Single-Breath Technique and Positive Expiratory Pressure in Infants. https://app.cochat.ai/papers/10.1164/ajrccm.159.1.9805021
The paper
WILDHABER, J. H., HALL, G. L., & STICK, S. M. (1999). Measurements of Exhaled Nitric Oxide with the Single-Breath Technique and Positive Expiratory Pressure in Infants. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.159.1.9805021

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.