The DOI matches its Crossref record.
Response of Ventilator-dependent Patients to Different Levels of Pressure Support and Proportional Assist
Abstract
The ventilator's response to the patient's effort is quite different in proportional assist ventilation (PAV) and pressure support ventilation (PSV). We wished to determine whether this results in different ventilatory and breathing pattern responses to alterations in level of support and, if so, whether there are any gas exchange consequences. Fourteen patients were studied. Average elastance (E) was 22.8 (range, 14 -36) cm H2O/L and average resistance (R) was 15. 7 (range, 9-21) cm H2O/L/s. The highest PSV support (PSVmax) was that associated with a tidal volume (VT) of 10 ml/kg (20.4 +/- 3.2 cm H2O), and the highest level of PAV assist (PAVmax) was 78 +/- 7% of E and 76 +/- 7% of R. Level of assist was decreased in steps to the lowest tolerable level (PSVmin, PAVmin). Minute ventilation, VT, ventilator rate (RRvent), and arterial gas tensions were measured at each level. We also determined the patient's respiratory rate (RRpat) by adding the number of ineffective efforts (DeltaRR) to RRvent. There was no difference between PSVmin and PAVmin in any of the variables. At PSVmax, VT was significantly higher (0.90 +/- 0.30 versus 0.51 +/- 0.16 L) and RRvent was significantly lower (13.2 +/- 3.9 versus 27.6 +/- 10.5 min-1) than at PAVmax. The difference in RRvent was largely related to a progressive increase in ineffective efforts on PSV as level increased (DeltaRR 12.1 +/- 10.1 vs 1.4 +/- 2.1 with PAVmax); there was no significant difference in RRpat. The differences in breathing pattern had no consequence on arterial blood gas tensions. We conclude that substantial differences in breathing pattern may occur between PSV and PAV and that these are largely artifactual and related to different patient-ventilator interactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Patient-ventilator asynchrony during assisted mechanical ventilation
Thille, A. W., Rodriguez, P., Cabello, B., Lellouche, F., & Brochard, L. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0301-8 · Cited by 930
The Application of Esophageal Pressure Measurement in Patients with Respiratory Failure
Akoumianaki, E., Maggiore, S. M., Valenza, F., Bellani, G., Jubran, A., Loring, S. H., Pelosi, P., Talmor, D., Grasso, S., Chiumello, D., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201312-2193ci · Cited by 635
Advances in Mechanical Ventilation
Tobin, M. J. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106283442606 · Cited by 475
Chemical Control Stability in Patients with Obstructive Sleep Apnea
YOUNES, M., OSTROWSKI, M., THOMPSON, W., LESLIE, C., & SHEWCHUK, W. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.5.2007013 · Cited by 439
Self-citationThille, A. W., Cabello, B., Galia, F., Lyazidi, A., & Brochard, L. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1121-9 · Cited by 288
Metadata
- Authors
- GIANNOULI, E., WEBSTER, K., ROBERTS, D., & YOUNES, M.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-06-01
- Volume
- 159
- Issue
- 6
- Pages
- 1716-1725
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2158640408
- Cited by
- 181
- References
- 0
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Response of Ventilator-dependent Patients to Different Levels of Pressure Support and Proportional Assist. https://app.cochat.ai/papers/10.1164/ajrccm.159.6.9704025
- The paper
- GIANNOULI, E., WEBSTER, K., ROBERTS, D., & YOUNES, M. (1999). Response of Ventilator-dependent Patients to Different Levels of Pressure Support and Proportional Assist. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.159.6.9704025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.