The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Effective Compliance during the First 3 Months of Continuous Positive Airway Pressure: A European Prospective Study of 121 Patients
Abstract
Effective compliance (time spent at the effective pressure) with nasal CPAP in obstructive sleep apnea has been reported to be poor. The aim of our study was to evaluate effective compliance in a large European multicenter study. One hundred twenty-one consecutive newly treated patients (initial apnea-hypopnea index [AHI] = 62.0 +/- 29. 5/h, AHI under CPAP = 6.4 +/- 8.1/h, CPAP pressure = 8.7 +/- 2.6 cm H(2)O, BMI = 33.1 +/- 6.8 kg/m(2)) were randomly allocated to a group with (MC(+)) (n = 58) or without (MC(-)) (n = 63) a control unit measuring effective compliance at 1, 2, and 3 mo, which was compared with the built-in time counter data. MC(+) data were 94 +/- 10, 98 +/- 5, and 96 +/- 9% of counter data at 1, 2, and 3 mo, respectively. Using criteria of regular use already reported in the literature (at least 4 h of nCPAP per day of use and nCPAP administered more than 70% of the days) we found 77, 82, and 79% compliant patients at 1, 2, and 3 mo, respectively, 79% of the patients meeting these criteria each month. Although there were no pulmonary functions or polysomnographic differences between the two subgroups, the compliant patients did report a greater improvement in minor symptoms. We found a close correlation between effective use of CPAP and the machine run time. The main result of our study was a higher effective compliance than previously reported, approximately 80% of the patients being regular users versus 46% in a previously published study. This may result from different technical and medical follow-up.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,376
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339
Engleman, H. M., Martin, S. E., Douglas, N. J., & Deary, I. J. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91522-9 · Cited by 592
Night-To-Night Variability in CPAP Use Over the First Three Months of Treatment
Weaver, T. E., Kribbs, N. B., Pack, A. I., Kline, L. R., Chugh, D. K., Maislin, G., Smith, P. L., Schwartz, A. R., Schubert, N. M., Gillen, K. A., et al. (1997) · Sleep · doi:10.1093/sleep/20.4.278 · Cited by 530
Side Effects of Nasal Continuous Positive Airway Pressure in Sleep Apnea Syndrome
Pépin, J. L., Leger, P., Veale, D., Langevin, B., Robert, D., & Lévy, P. (1995) · Chest · doi:10.1378/chest.107.2.375 · Cited by 422
Self-citationKribbs, N. B., Pack, A. I., Kline, L. R., Getsy, J. E., Schuett, J. S., Henry, J. N., Maislin, G., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.5.1162 · Cited by 395
Compliance with CPAP therapy in patients with the sleep apnoea/hypopnoea syndrome.
Engleman, H. M., Martin, S. E., & Douglas, N. J. (1994) · Thorax · doi:10.1136/thx.49.3.263 · Cited by 358
Nasal CPAP: an objective evaluation of patient compliance.
Reeves-Hoche, M. K., Meck, R., & Zwillich, C. W. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.1.8111574 · Cited by 357
Hoffstein, V., Viner, S., Mateika, S., & Conway, J. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/145.4_pt_1.841 · Cited by 317
(1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.6.7952642 · Cited by 299
Cited by
Obstructive sleep apnoea syndrome
Lévy, P., Kohler, M., McNicholas, W. T., Barbé, F., McEvoy, R. D., Somers, V. K., Lavie, L., & Pépin, J.-L. (2015) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2015.15 · Cited by 1,235
Self-citationEvaluation of Positive Airway Pressure Treatment for Sleep Related Breathing Disorders in Adults
Gay, P., Weaver, T., Loube, D., & Iber, C. (2006) · Sleep · doi:10.1093/sleep/29.3.381 · Cited by 614
Improving CPAP use by patients with the sleep apnoea/hypopnoea syndrome (SAHS)
Engleman, H. M., & Wild, M. R. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2001.0197 · Cited by 473
Long-term Compliance Rates to Continuous Positive Airway Pressure in Obstructive Sleep Apnea
Sin, D. D., Mayers, I., Man, G. C. W., & Pawluk, L. (2002) · Chest · doi:10.1378/chest.121.2.430 · Cited by 379
Wozniak, D. R., Lasserson, T. J., & Smith, I. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007736.pub2 · Cited by 379
Metadata
- Authors
- PÉPIN, J. L., KRIEGER, J., RODENSTEIN, D., CORNETTE, A., SFORZA, E., DELGUSTE, P., DESCHAUX, C., GRILLIER, V., & LÉVY, P.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-10-01
- Volume
- 160
- Issue
- 4
- Pages
- 1124-1129
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2093737681
- Cited by
- 274
- References
- 25
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effective Compliance during the First 3 Months of Continuous Positive Airway Pressure: A European Prospective Study of 121 Patients. https://app.cochat.ai/papers/10.1164/ajrccm.160.4.9802027
- The paper
- PÉPIN, J. L., KRIEGER, J., RODENSTEIN, D., CORNETTE, A., SFORZA, E., DELGUSTE, P., DESCHAUX, C., GRILLIER, V., & LÉVY, P. (1999). Effective Compliance during the First 3 Months of Continuous Positive Airway Pressure: A European Prospective Study of 121 Patients. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.160.4.9802027
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.