The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effects of Decreased Respiratory Frequency on Ventilator-induced Lung Injury
Abstract
To determine if decreased respiratory frequency (ventilatory rate) improves indices of lung damage, 17 sets of isolated, perfused rabbit lungs were ventilated with a peak static airway pressure of 30 cm H(2)O. All lungs were randomized to one of three frequency/peak pulmonary artery pressure combinations: F20P35 (n = 6): ventilatory frequency, 20 breaths/min, and peak pulmonary artery pressure, 35 mm Hg; F3P35 (n = 6), ventilatory frequency, 3 breaths/min, and peak pulmonary artery pressure of 35 mm Hg; or F20P20 (n = 5), ventilatory frequency, 20 breaths/min, and peak pulmonary artery pressure, 20 mm Hg. Mean airway pressure and tidal volume were matched between groups. Mean pulmonary artery pressure and vascular flow were matched between groups F20P35 and F3P35. The F20P35 group showed at least a 4.5-fold greater mean weight gain and a 3-fold greater mean incidence of perivascular hemorrhage than did the comparison groups, all p </= 0.05. F20P35 lungs also displayed more alveolar hemorrhage than did F20P20 lungs (p </= 0.05). We conclude that decreasing respiratory frequency can improve these indices of lung damage, and that limitation of peak pulmonary artery pressure and flow may diminish lung damage for a given ventilatory pattern.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In Vitro fatigue of Human Tendons
Schechtman, H., & Bader, D. L. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00033-x · Cited by 218
Cited by
Ventilator-related causes of lung injury: the mechanical power
Gattinoni, L., Tonetti, T., Cressoni, M., Cadringher, P., Herrmann, P., Moerer, O., Protti, A., Gotti, M., Chiurazzi, C., Carlesso, E., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4505-2 · Cited by 1,055
Gajic, O., Dara, S. I., Mendez, J. L., Adesanya, A. O., Festic, E., Caples, S. M., Rana, R., St. Sauver, J. L., Lymp, J. F., Afessa, B., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000133019.52531.30 · Cited by 739
PUTENSEN, C., ZECH, S., WRIGGE, H., ZINSERLING, J., STÜBER, F., VON SPIEGEL, T., & MUTZ, N. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.1.2001078 · Cited by 638
Asynchronies during mechanical ventilation are associated with mortality
Blanch, L., Villagra, A., Sales, B., Montanya, J., Lucangelo, U., Luján, M., García-Esquirol, O., Chacón, E., Estruga, A., Oliva, J. C., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3692-6 · Cited by 539
Self-citationMechanical Power and Development of Ventilator-induced Lung Injury
Cressoni, M., Gotti, M., Chiurazzi, C., Massari, D., Algieri, I., Amini, M., Cammaroto, A., Brioni, M., Montaruli, C., Nikolla, K., et al. (2016) · Anesthesiology · doi:10.1097/aln.0000000000001056 · Cited by 483
Metadata
- Authors
- HOTCHKISS, J. R., BLANCH, L., MURIAS, G., ADAMS, A. B., OLSON, D. A., WANGENSTEEN, O. D., LEO, P. H., & MARINI, J. J.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-02-01
- Volume
- 161
- Issue
- 2
- Pages
- 463-468
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2165560736
- Cited by
- 249
- References
- 1
- FWCI
- 7.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Decreased Respiratory Frequency on Ventilator-induced Lung Injury. https://app.cochat.ai/papers/10.1164/ajrccm.161.2.9811008
- The paper
- HOTCHKISS, J. R., BLANCH, L., MURIAS, G., ADAMS, A. B., OLSON, D. A., WANGENSTEEN, O. D., LEO, P. H., & MARINI, J. J. (2000). Effects of Decreased Respiratory Frequency on Ventilator-induced Lung Injury. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.161.2.9811008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.