Clinical Evaluation of a Computer-controlled Pressure Support Mode
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
We have designed a computerized system providing closed-loop control of the level of pressure support ventilation (PSV). The system sets itself at the lowest level of PSV that maintains respiratory rate (RR), tidal volume (VT), and end-tidal CO(2) pressure (PET(CO(2))) within predetermined ranges defining acceptable ventilation (i.e., 12 < RR < 28 cycles/min, VT > 300 ml [> 250 if weight < 55 kg], and PET(CO(2)) < 55 mm Hg [< 65 mm Hg if chronic CO(2) retention]). Ten patients received computer-controlled (automatic) PSV and physician-controlled (standard) PSV, in random order, during 24 h for each mode. An estimation of occlusion pressure (P(0.1)) was recorded continuously. The average time spent with acceptable ventilation as previously defined was 66 +/- 24% of the total ventilation time with standard PSV versus 93 +/- 8% with automatic PSV (p < 0.05), whereas the level of PSV was similar during the two periods (17 +/- 4 cm H(2)O versus 19 +/- 6 cm H(2)O). The time spent with an estimated P(0.1) above 4 cm H(2)O was 34 +/- 35% of the standard PSV time versus only 11 +/- 17% of the automatic PSV time (p < 0.01). Automatic PSV increased the time spent within desired ventilation parameter ranges and apparently reduced periods of excessive workload.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A simplified acute physiology score for ICU patients
GALL, J.-R. L., LOIRAT, P., ALPEROVITCH, A., GLASER, P., GRANTHIL, C., MATHIEU, D., MERCIER, P., THOMAS, R., & VILLERS, D. (1984) · Critical Care Medicine · doi:10.1097/00003246-198411000-00012 · Cited by 1,251
Occlusion pressure as a measure of respiratory center output cm conscious man
Whitelaw, W. A., Derenne, J.-P., & Milic-Emili, J. (1975) · Respiration Physiology · doi:10.1016/0034-5687(75)90059-6 · Cited by 740
Brochard, L., Harf, A., Lorino, H., & Lemaire, F. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/139.2.513 · Cited by 630
Self-citationPRINCIPLES AND PRACTICE OF MECHANICAL VENTILATION
Tobin, M. J. (1996) · Shock · doi:10.1097/00024382-199601000-00018 · Cited by 562
Respiratory Function during Pressure Support Ventilation
MacIntyre, N. R. (1986) · Chest · doi:10.1378/chest.89.5.677 · Cited by 415 · cited 1×
“2 Pressure support ventilation (PSV) is a mode of partial respiratory support that is widely used to assist patients, especially during gradual withdrawal from mechanical ventilation (1, 2, 3, 4).”
BackgroundTobin, M. J., Perez, W., Guenther, S. M., Semmes, B. J., Mador, M. J., Allen, S. J., Lodato, R. F., & Dantzker, D. R. (1986) · PubMed · doi:10.1164/arrd.1986.134.5.1111 · Cited by 415 · cited 1×
“RR, which seems to reflect how well the respiratory muscles adapt to the workload (14), is the main parameter, while V T and P ETCO2 are used to improve safety.”
Method(1987) · Journal of Critical Care · doi:10.1016/0883-9441(87)90022-0 · Cited by 335
Pattern of recovery from diaphragmatic fatigue over 24 hours
Laghi, F., D'Alfonso, N., & Tobin, M. J. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.2.539 · Cited by 201 · cited 1×
“This may have important implications for facilitating recovery from or avoiding respiratory muscle fatigue (15).”
BackgroundP0.1 is a useful parameter in setting the level of pressure support ventilation
Alberti, A., Gallo, F., Fongaro, A., Valenti, S., & Rossi, A. (1995) · Intensive Care Medicine · doi:10.1007/bf01700158 · Cited by 164
Brochard, L. J. (1991) · Update in intensive care and emergency medicine · doi:10.1007/978-3-642-84554-3_22 · Cited by 125 · cited 1×
“2 Pressure support ventilation (PSV) is a mode of partial respiratory support that is widely used to assist patients, especially during gradual withdrawal from mechanical ventilation (1, 2, 3, 4).”
BackgroundSelf-citationMiksch, S., Horn, W., Popow, C., & Paky, F. (1996) · Artificial Intelligence in Medicine · doi:10.1016/s0933-3657(96)00355-7 · Cited by 116 · cited 1×
“They deal in general with complex problems such as ventilation of newborn infants (21) or design of general architectures for intensive-care monitoring (22, 23) and explore sophisticated techniques coming from Artificial Intelligence.”
BackgroundA Computer-controlled Ventilator Weaning System
Strickland, J. H., & Hasson, J. H. (1993) · CHEST Journal · doi:10.1378/chest.103.4.1220 · Cited by 105 · cited 3×
“Our work is similar to that by Strickland and Hasson (26, 27), who developed a closed-loop system that modifies the setting of synchronized intermittent mandatory ventilation and of PSV for intervening breaths based on RR, VT, and pulse oximeter oxygen saturation measurements.”
ResultInfluentialNéoGanesh: a working system for the automated control of assisted ventilation in ICUs
Dojat, M., Pachet, F., Guessoum, Z., Touchard, D., Harf, A., & Brochard, L. (1997) · Artificial Intelligence in Medicine · doi:10.1016/s0933-3657(97)00025-0 · Cited by 70
Self-citationEstimation of Occlusion Pressure During Assisted Ventilation in Patients With Intrinsic PEEP
Conti, G., Cinnella, G., Barboni, E., Lemaire, F., HARF, A., & Brochard, L. J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.4.8887584 · Cited by 61 · cited 1×
“1 can be estimated from the negative Paw generated by the patient’s inspiratory effort during this pause (11, 12).”
BackgroundSelf-citationWork of Breathing and Airway Occlusion Pressure during Assist-Mode Mechanical Ventilation
Sassoon, C. S. H., Mahutte, C. K., Te, T. T., Simmons, D. H., & Light, R. W. (1988) · CHEST Journal · doi:10.1378/chest.93.3.571 · Cited by 54
Evaluation of a medical diagnosis system using simulator test scenarios
Larsson, J. E., Hayes‐Roth, B., Gaba, D. M., et al. (1997) · Artificial Intelligence in Medicine · doi:10.1016/s0933-3657(97)00027-4 · Cited by 31 · cited 1×
“They usually deal with complex problems—such as the ventilation of neonates (21) or the design of general architectures for intensive care monitoring (22, 23)—and explore sophisticated techniques coming from the area of artificial intelligence.”
Background
Cited by
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Evidence-Based Guidelines for Weaning and Discontinuing Ventilatory Support
MacIntyre, N. R. (2001) · Chest · doi:10.1378/chest.120.6_suppl.375s · Cited by 1,240
A Multicenter Randomized Trial of Computer-driven Protocolized Weaning from Mechanical Ventilation
Lellouche, F., Mancebo, J., Jolliet, P., Roeseler, J., Schortgen, F., Dojat, M., Cabello, B., Bouadma, L., Rodriguez, P., Maggiore, S., et al. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200511-1780oc · Cited by 406
Self-citationMechanical Ventilator Weaning Protocols Driven by Nonphysician Health-Care Professionals
Ely, E. W., Meade, M. O., Haponik, E. F., Kollef, M. H., Cook, D. J., Guyatt, G. H., & Stoller, J. K. (2001) · Chest · doi:10.1378/chest.120.6_suppl.454s · Cited by 288
Thille, A. W., Cabello, B., Galia, F., Lyazidi, A., & Brochard, L. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1121-9 · Cited by 288
Self-citation
Metadata
- Authors
- DOJAT, M., HARF, A., TOUCHARD, D., LEMAIRE, F., & BROCHARD, L.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-04-01
- Volume
- 161
- Issue
- 4
- Pages
- 1161-1166
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2170278755
- Cited by
- 159
- References
- 16
- FWCI
- 6.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.