A Randomized, Controlled Crossover Trial of Two Oral Appliances for Sleep Apnea Treatment
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Our purpose was to compare the effectiveness and side effects of a novel, single-piece mandibular advancement device (OSA-Monobloc) for sleep apnea therapy with those of a two-piece appliance with lateral Herbst attachments (OSA-Herbst) as used in previous studies. An OSA-Monobloc and an OSA-Herbst with equal protrusion were fitted in 24 obstructive sleep apnea patients unable to use continuous positive airway pressure (CPAP) therapy. After an adaptation period of 156 ± 14 d (mean ± SE), patients used the OSA-Monobloc, the OSA-Herbst, and no appliance in random order, using each appliance for 1 wk. Symptom scores were recorded and sleep studies were done at the end of each week. Several symptom scores were significantly improved with both appliances, but to a greater degree with the OSA-Monobloc. Epworth Sleepiness Scale scores were 8.8 ± 0.7 with the OSA-Herbst, and 8.6 ± 0.8 with the OSA-Monobloc devices, and 13.1 ± 0.9 without therapy (p < 0.05 versus both appliances). The apnea/hypopnea index was 8.7 ± 1.5/h with the OSA-Herbst and 7.9 ± 1.6/h with the OSA-Monobloc device, and 22.6 ± 3.1/h without therapy (p < 0.05 versus both appliances). Side effects were mild and of equal prevalence with both appliances. Fifteen patients preferred the OSA-Monobloc, eight patients had no preference, and one patient preferred the OSA-Herbst device (p < 0.008 versus OSA-Monobloc). We conclude that both the OSA-Herbst and the OSA-Monobloc are effective therapeutic devices for sleep apnea. The OSA-Monobloc relieved symptoms to a greater extent than the OSA-Herbst, and was preferred by the majority of patients on the basis of its simple application.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Comparison between device designs indicated that there are only minor differences in treatment effects between custom-made devices 78, 80, 83, 84, while a prefabricated device was less effective 85.”
From Non-CPAP therapies in obstructive sleep apnoea (2011) · cites this paper as [78]
In the citing paper
“Initial side-effects, such as jaw discomfort, tooth tenderness, excessive salivation and/or temporary occlusal changes, were reported in slightly more than half of the patients 63, 65, 69, 71–74, 78, and more frequently from MAD than from a control plate 64.”
From Non-CPAP therapies in obstructive sleep apnoea (2011) · cites this paper as [78]
Citations
Cites
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,637
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339
Jenkinson, C., Davies, R. J., Mullins, R., & Stradling, J. R. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10532-9 · Cited by 826
The Sleep Disorders Questionnaire I: Creation and Multivariate Structure of SDQ
Douglass, A. B., Bomstein, R., Nino-Murcia, G., Keenan, S., Miles, L., Zarcone, V. P., Guilleminault, C., & Dement, W. C. (1994) · Sleep · doi:10.1093/sleep/17.2.160 · Cited by 559
ENGLEMAN, H. M., KINGSHOTT, R. N., WRAITH, P. K., MACKAY, T. W., DEARY, I. J., & DOUGLAS, N. J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.2.9803121 · Cited by 558
Ferguson, K. A., Ono, T., Lowe, A. A., Keenan, S. P., & Fleetham, J. A. (1996) · Chest · doi:10.1378/chest.109.5.1269 · Cited by 495
Ferguson, K. A., Ono, T., Lowe, A. A., al-Majed, S., Love, L. L., & Fleetham, J. A. (1997) · Thorax · doi:10.1136/thx.52.4.362 · Cited by 391
BALLESTER, E., BADIA, J. R., HERNÁNDEZ, L., CARRASCO, E., de PABLO, J., FORNAS, C., RODRIGUEZ-ROISIN, R., & MONTSERRAT, J. M. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.2.9804061 · Cited by 349
The effect of sleep fragmentation on daytime function.
Martin, S. E., Engleman, H. M., Deary, I. J., & Douglas, N. J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.153.4.8616562 · Cited by 327
Research works printed but not linked: 2
- Kaplan, 1996, Compliance mit nasaler Ueberdruckbehandlung (CPAP) bei obstruktivem Schlafapnoe Syndrom., Schweiz. Med. Wochenschr., 130, 15
- Sleep Disorders Atlas Task Force of the American Sleep Disorders Association, 1992, EEG arousals: scoring rules and examples., Sleep, 15, 174
Cited by
Ramar, K., Dort, L. C., Katz, S. G., Lettieri, C. J., Harrod, C. G., Thomas, S. M., & Chervin, R. D. (2015) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.4858 · Cited by 915
Oral Appliances for Snoring and Obstructive Sleep Apnea: A Review
Ferguson, K. A., Cartwright, R., Rogers, R., & Schmidt-Nowara, W. (2006) · Sleep · doi:10.1093/sleep/29.2.244 · Cited by 687
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Oral Appliance Treatment for Obstructive Sleep Apnea: An Update
Sutherland, K., Vanderveken, O. M., Tsuda, H., Marklund, M., Gagnadoux, F., Kushida, C. A., Cistulli, P. A., & on behalf of the ORANGE-Registry (Oral Appliance Network on Global Effectiveness) (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3460 · Cited by 515
Mechanisms of vascular damage in obstructive sleep apnea
Kohler, M., & Stradling, J. R. (2010) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2010.145 · Cited by 513
Metadata
- Authors
- BLOCH, K. E., ISELI, A., ZHANG, J. N., XIE, X., KAPLAN, V., STOECKLI, P. W., & RUSSI, E. W.
- Affiliations
- University of Zurich (CH)
- Department of Internal Medicine, University Hospital of Zürich, and Department of Orthodontics and Dentofacial Orthopedics, University of Zürich, Zürich, Switzerland
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-07-01
- Volume
- 162
- Issue
- 1
- Pages
- 246-251
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2101791017
- Cited by
- 223
- References
- 27
- Citations by year
- 2026: 1 · 2025: 6 · 2024: 3 · 2023: 4 · 2022: 10 · 2021: 6 · 2020: 9 · 2019: 10 · 2018: 8 · 2017: 13 · 2016: 13 · 2015: 12 · 2014: 14 · 2013: 8 · 2012: 11
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Respiratory and Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
- Health Sciences › Dentistry › Orthodontics › Orthodontics and Dentofacial Orthopedics
- Keywords
- obstructive sleep apnea, mandibular advancement device, oral appliances, apnea-hypopnea index, daytime sleepiness, patient preferences
- MeSH terms
- Equipment Design, Follow-Up Studies, Humans, Middle Aged, Orthodontic Appliances, Removable, Prospective Studies, Cross-Over Studies, Sleep Apnea, Obstructive
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Randomized, Controlled Crossover Trial of Two Oral Appliances for Sleep Apnea Treatment. https://app.cochat.ai/papers/10.1164/ajrccm.162.1.9908112
- The paper
- BLOCH, K. E., ISELI, A., ZHANG, J. N., XIE, X., KAPLAN, V., STOECKLI, P. W., & RUSSI, E. W. (2000). A Randomized, Controlled Crossover Trial of Two Oral Appliances for Sleep Apnea Treatment. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.162.1.9908112
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.