Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

A comparison of the Twin Block and Herbst mandibular advancement splints in the treatment of patients with obstructive sleep apnoea: a prospective study

Lawton, H. M. · 2005 · The European Journal of Orthodontics

Abstract

This prospective, randomized, crossover study of 16 patients with obstructive sleep apnoea (OSA) [12 males, four females; median body mass index (BMI) 29.2 kg/m(2) (range 23.8-51.1); median age 44.8 years (range 24.0-68.4)] analysed the efficacy of the Twin Block (TB) in relation to the Herbst appliance as a mandibular advancement splint (MAS). Each subject was fitted with a TB and Herbst MAS in a random order with a washout period of 2 weeks between appliances. Once each patient was subjectively happy with the performance of each appliance, questionnaires and a visual analogue scale (VAS) were used to determine differences in snoring, daytime sleepiness, quality of life, side-effects of the appliances and patient preference. All patients underwent overnight domiciliary sleep recordings prior to and after fitting each appliance in order to objectively assess sleep quality in terms of the apnoea-hypopnoea index (AHI), snoring frequency and arterial oxygen saturation. The results suggested that there was no difference in the treatment performance of the TB and Herbst MAS for AHI (P = 0.71), snoring frequency (P = 0.49), arterial blood oxygen saturation (P = 0.97), quality of life and side-effects. The Herbst MAS proved to be the more effective appliance for reducing daytime sleepiness (P = 0.04) and was the more popular appliance among the patients. Side-effects with both appliances were minor and improved in the longer term. The TB MAS represents a viable alternative to the Herbst MAS in the treatment of patients with OSA.

Overview

Integrity signals

Registry

Crossref · 10.1093/ejo/cjh067

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 32 references

Cited by

See all 127

Metadata

Authors
Lawton, H. M.
Affiliations
Royal London Hospital (GB)
Corresponding author
Lawton, H. M.
Venue
The European Journal of Orthodontics
Published
2005-02-01
Volume
27
Issue
1
Pages
82-90
ISSN
  • 0141-5387 (ISSN-L)
  • 1460-2210
OpenAlex
W2141345969
Cited by
127
References
32
Citations by year
2026: 4 · 2025: 3 · 2024: 2 · 2023: 5 · 2022: 3 · 2021: 5 · 2020: 5 · 2019: 3 · 2018: 4 · 2017: 9 · 2016: 6 · 2015: 22 · 2014: 18 · 2013: 8 · 2012: 3
FWCI
2.40
Type
journal article
Language
en
Open access
closed
Locations
  • European Journal of Orthodontics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Dentistry › Orthodontics › Orthodontics and Dentofacial Orthopedics
  • Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
Keywords
obstructive sleep apnea, mandibular advancement device, Twin Block appliance, Herbst appliance, snoring, daytime sleepiness, apnea-hypopnea index, oxygen saturation, quality of life, patient preferences
MeSH terms
Adult, Aged, Female, Humans, Male, Middle Aged, Oxygen, Prospective Studies, Quality of Life, Sleep, Sleep Stages, Snoring, Body Mass Index, Treatment Outcome, Patient Satisfaction, Orthodontic Appliances, Functional, Cross-Over Studies, Mandibular Advancement, Sleep Apnea, Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparison of the Twin Block and Herbst mandibular advancement splints in the treatment of patients with obstructive sleep apnoea: a prospective study. https://app.cochat.ai/papers/10.1093/ejo/cjh067
The paper
Lawton, H. M. (2005). A comparison of the Twin Block and Herbst mandibular advancement splints in the treatment of patients with obstructive sleep apnoea: a prospective study. The European Journal of Orthodontics. https://doi.org/10.1093/ejo/cjh067

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.