Determinants of the Exercise Endurance Capacity in Patients with Chronic Obstructive Pulmonary Disease: The Power–Duration Relationship
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
To characterize the determinants of the power-duration (W-t) relationship in patients with chronic obstructive pulmonary disease (COPD), we evaluated 8 nonhypoxemic patients (FEV(1) = 1.27 +/- 0.26 L) and 10 healthy controls. After an initial maximum-incremental exercise test on cycle ergometer (peak), the subjects underwent four high-intensity constant-load tests to the limit of tolerance (t), each on different days. The W-t relationship was found to be hyperbolic in both groups. Absolute values of both the critical power asymptote (theta(F)) and the curvature constant (W') were lower in patients than in control subjects. However, when expressed as percentage of peak work rate theta(F) was significantly higher in patients compared with control subjects (81.8 +/- 3.3% versus 67.5 +/- 3.7%, respectively, p < 0.01). There were severe reductions in t in the patients that were consistently associated with higher breathlessness scores and V E/MVV ratios. Interestingly, all patients were able to sustain exercise at theta(F) for 20 min despite near-maximum physiological and subjective stresses. We conclude that the reductions of both parameters of the hyperbolic W-t relationship (theta(F) and W') in patients with COPD were due to the ventilatory constraints and their sensory consequences. Importantly, theta(F) separated a "sustainable" from a "nonsustainable" exercise-intensity domain: this parameter consistently occurred closer to peak work rate in patients than the healthy control subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Self-citationChanges in the normal maximal expiratory flow-volume curve with growth and aging.
Knudson, R. J., Lebowitz, M. D., Holberg, C. J., & Burrows, B. A. (1983) · PubMed · doi:10.1164/arrd.1983.127.6.725 · Cited by 1,907
Ries, A. L., Kaplan, R. M., Limberg, T. M., & Prewitt, L. M. (1995) · Annals of Internal Medicine · doi:10.7326/0003-4819-122-11-199506010-00003 · Cited by 903
Lean body mass estimation by bioelectrical impedance analysis: a four-site cross-validation study
Segal, K., Van Loan, M., Fitzgerald, P., Hodgdon, A., & Van Itallie, T. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/47.1.7 · Cited by 881
O'Donnell, D. E., & Webb, K. A. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.5.1351 · Cited by 543
Schols, A., Wouters, E., Soeters, P., & Westerterp, K. (1991) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/53.2.421 · Cited by 246
Cited by
Maltais, F., Decramer, M., Casaburi, R., Barreiro, E., Burelle, Y., Debigaré, R., Dekhuijzen, P. N. R., Franssen, F., Gayan-Ramirez, G., Gea, J., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201402-0373st · Cited by 1,090
Dynamic Hyperinflation and Exercise Intolerance in Chronic Obstructive Pulmonary Disease
O'DONNELL, D. E., REVILL, S. M., & WEBB, K. A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.5.2012122 · Cited by 1,076
Recommendations on the use of exercise testing in clinical practice
Palange, P., Ward, S. A., Carlsen, K.-H., Casaburi, R., Gallagher, C. G., Gosselink, R., O'Donnell, D. E., Puente-Maestu, L., Schols, A. M., Singh, S., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00046906 · Cited by 718
Self-citationPulmonary Rehabilitation in Chronic Obstructive Pulmonary Disease
Troosters, T., Casaburi, R., Gosselink, R., & Decramer, M. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200408-1109so · Cited by 649
Critical Power: Implications for Determination of V˙O2max and Exercise Tolerance
JONES, A. M., VANHATALO, A., BURNLEY, M., MORTON, R. H., & POOLE, D. C. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d9cf7f · Cited by 549
Critical Power: An Important Fatigue Threshold in Exercise Physiology
POOLE, D. C., BURNLEY, M., VANHATALO, A., ROSSITER, H. B., & JONES, A. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000939 · Cited by 535
Use of exercise testing in the evaluation of interventional efficacy: an official ERS statement
Puente-Maestu, L., Palange, P., Casaburi, R., Laveneziana, P., Maltais, F., Neder, J. A., O'Donnell, D. E., Onorati, P., Porszasz, J., Rabinovich, R., et al. (2016) · European Respiratory Journal · doi:10.1183/13993003.00745-2015 · Cited by 412
Self-citationThe anaerobic threshold: 50+ years of controversy
Poole, D. C., Rossiter, H. B., Brooks, G. A., & Gladden, L. B. (2021) · The Journal of Physiology · doi:10.1113/jp279963 · Cited by 312
“…specifically, running (Hughson et al. 1984; Fukuba & Whipp, 1999; Fukuba et al. 2003; Broxterman et al. 2013), cycling (Poole et al. 1988, 1990;Hill, 1993;Neder et al. 2000a,b ; Pringle& Jones, 2002; Hill, 2004; Vanhatalo et al. 2007), swimming (Wakayoshi et al. 1993) and rowing (Hill et al. 2003).”
Neder, J. A. (2002) · Thorax · doi:10.1136/thorax.57.4.333 · Cited by 307
Self-citationMaltais, F., Hamilton, A., Marciniuk, D., Hernandez, P., Sciurba, F. C., Richter, K., Kesten, S., & O’Donnell, D. (2005) · Chest · doi:10.1378/chest.128.3.1168 · Cited by 305
Interval training as an alternative modality to continuous exercise in patients with COPD
Vogiatzis, I., Nanas, S., & Roussos, C. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.01152001 · Cited by 277
Porszasz, J., Emtner, M., Goto, S., Somfay, A., Whipp, B. J., & Casaburi, R. (2005) · Chest · doi:10.1378/chest.128.4.2025 · Cited by 262
Self-citationPalange, P., Valli, G., Onorati, P., Antonucci, R., Paoletti, P., Rosato, A., Manfredi, F., & Serra, P. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01207.2003 · Cited by 162
Chiappa, G. R., Queiroga, F., Meda, E., Ferreira, L. F., Diefenthaeler, F., Nunes, M., Vaz, M. A., Machado, M. C. L., Nery, L. E., & Neder, J. A. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200811-1793oc · Cited by 122
“, the closer the work rate to critical power, the larger the potential for improvement after any intervention) (33).”
BackgroundSelf-citationReliability of ventilatory parameters during cycle ergometry in multicentre trials in COPD
O’Donnell, D. E., Travers, J., Webb, K. A., He, Z., Lam, Y.-M., Hamilton, A., Kesten, S., Maltais, F., & Magnussen, H. (2009) · European Respiratory Journal · doi:10.1183/09031936.00168708 · Cited by 113
Casaburi, R. (2005) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1081/copd-200050576 · Cited by 87
Factors Limiting Exercise Tolerance in Chronic Lung Diseases
Vogiatzis, I., & Zakynthinos, S. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c110015 · Cited by 77
“Exercise tolerance during constant-load cycle ergometer testing has been documented to largely depend on the imposed workload as the time to the limit of tolerance in COPD decreases (similarly to normal subjects) hyperbolically as a function of power output (206) (Fig.”
Collins, E. G., Langbein, W. E., Fehr, L., O'Connell, S., Jelinek, C., Hagarty, E., Edwards, L., Reda, D., Tobin, M. J., & Laghi, F. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200703-477oc · Cited by 63
Effects of formoterol on exercise tolerance in severely disabled patients with COPD
Neder, J. A., Fuld, J. P., Overend, T., Thirlwell, J., Carter, R., Stevenson, R., & Ward, S. A. (2007) · Respiratory Medicine · doi:10.1016/j.rmed.2007.06.006 · Cited by 47
“0 [25–170]W.”
Self-citationPerformance During Constant Workrate Cycling Exercise in Women with COPD and Hyperinflation
Laviolette, L., O'Donnell, D. E., Webb, K. A., Hamilton, A. L., Kesten, S., & Maltais, F. (2009) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550903140873 · Cited by 15
Exercise tolerance with helium-hyperoxia versus hyperoxia in hypoxaemic patients with COPD
Queiroga, F., Nunes, M., Meda, E., Chiappa, G., Machado, M. C., Nery, L. E., & Neder, J. A. (2013) · European Respiratory Journal · doi:10.1183/09031936.00087812 · Cited by 14
Self-citation
Metadata
- Authors
- NEDER, J. A., JONES, P. W., NERY, L. E., & WHIPP, B. J.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-08-01
- Volume
- 162
- Issue
- 2
- Pages
- 497-504
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2155592471
- Cited by
- 158
- References
- 6
- FWCI
- 8.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.