FEV 6 Is an Acceptable Surrogate for FVC in the Spirometric Diagnosis of Airway Obstruction and Restriction
The DOI matches its Crossref record.
Abstract
We analyzed the FEV(1)/FEV(6) and FEV(1)/FVC results of 502 consecutive patients in the spirometric diagnosis of airway obstruction. We also examined the agreement between FEV(6) and FVC in the spirometric diagnosis of restriction. Technically acceptable test results were obtained from 337 subjects (67%). The sensitivity of FEV(1)/FEV(6) for diagnosing airway obstruction as defined by FEV(1)/ FVC was 95.0%; the specificity was 97.4%. When interpretations differed, the measured values were all close to the lower limits of the reference ranges. When analysis included +/- 100-ml variability in FEV(1) and FEV(6), the sensitivity increased to 99.5% and the specificity to 100%. The reproducibility of FEV(6) was superior to that of FVC. These results suggest that FEV(6) is an accurate, reliable alternative to FVC for diagnosing airway obstruction and that FEV(6) is reasonably comparable to FVC for the spirometric diagnosis of restriction. FEV(6) is more reproducible and less physically demanding for patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034805 · Cited by 15,627
Self-citationQuanjer, P. H., Stanojevic, S., Cole, T. J., Baur, X., Hall, G. L., Culver, B. H., Enright, P. L., Hankinson, J. L., Ip, M. S. M., Zheng, J., et al. (2012) · European Respiratory Journal · doi:10.1183/09031936.00080312 · Cited by 5,919
Graham, B. L., Steenbruggen, I., Miller, M. R., Barjaktarevic, I. Z., Cooper, B. G., Hall, G. L., Hallstrand, T. S., Kaminsky, D. A., McCarthy, K., McCormack, M. C., et al. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201908-1590st · Cited by 4,305
Self-citationGeneral considerations for lung function testing
Miller, M. R., Crapo, R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Enright, P., Grinten, C. P. M. V. D., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034505 · Cited by 2,026
Self-citationBurden and clinical features of chronic obstructive pulmonary disease (COPD)
Pauwels, R. A., & Rabe, K. F. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16855-4 · Cited by 1,004
Outcomes for COPD pharmacological trials: from lung function to biomarkers
Cazzola, M., MacNee, W., Martinez, F. J., Rabe, K. F., Franciosi, L. G., Barnes, P. J., Brusasco, V., Burge, P. S., Calverley, P. M. A., Celli, B. R., et al. (2008) · European Respiratory Journal · doi:10.1183/09031936.00099306 · Cited by 858
Minimal Clinically Important Differences in COPD Lung Function
Donohue, J. F. (2005) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1081/copd-200053377 · Cited by 529
Rabe, K. F., Bateman, E. D., O'Donnell, D., Witte, S., Bredenbröker, D., & Bethke, T. D. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67100-0 · Cited by 475
The Burden of Obstructive Lung Disease Initiative (BOLD): Rationale and Design
Buist, A. S., Vollmer, W., Sullivan, S., Weiss, K., Lee, T., Menezes, A., Crapo, R., Jensen, R., & Burney, P. (2005) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1081/copd-200057610 · Cited by 327
Self-citationEffect of 1-Year Treatment with Roflumilast in Severe Chronic Obstructive Pulmonary Disease
Calverley, P. M. A., Sanchez-Toril, F., McIvor, A., Teichmann, P., Bredenbroeker, D., & Fabbri, L. M. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200610-1563oc · Cited by 325
García-Río, F., Calle, M., Burgos, F., Casan, P., del Campo, F., Galdiz, J. B., Giner, J., González-Mangado, N., Ortega, F., & Puente Maestu, L. (2013) · Archivos de Bronconeumología · doi:10.1016/j.arbres.2013.04.001 · Cited by 283
Comparison of spirometry criteria for the diagnosis of COPD: results from the BOLD study
Vollmer, W. M., Gíslason, Þ., Burney, P., Enright, P. L., Gulsvik, A., Kocabas, A., & Buist, A. S. (2009) · European Respiratory Journal · doi:10.1183/09031936.00164608 · Cited by 265
Spirometric Criteria for Airway Obstruction
Hansen, J. E., Sun, X.-G., & Wasserman, K. (2007) · Chest · doi:10.1378/chest.06-1349 · Cited by 239
Standardisation of lung function testing: helpful guidance from the ATS/ERS Task Force
Laszlo, G. (2006) · Thorax · doi:10.1136/thx.2006.061648 · Cited by 223
The Clinical Importance of Dynamic Lung Hyperinflation in COPD
O'Donnell, D. E., & Laveneziana, P. (2006) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550600977478 · Cited by 197
“Measurements of timed vital capacity or forced expiratory volume in 6 seconds (FEV6) appear to be more sensitive than FVC in detecting enhanced lung emptying after pharmacotherapy (72, 73).”
BackgroundVandevoorde, J., Verbanck, S., Schuermans, D., Kartounian, J., & Vincken, W. (2005) · Chest · doi:10.1378/chest.127.5.1560 · Cited by 164
Spirometric reference equations for European females and males aged 65–85 yrs
García-Río, F., Pino, J. M., Dorgham, A., Alonso, A., & Villamor, J. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00088403 · Cited by 128
“Finally, only one previous study [6] provides reference values for elderly subjects for forced expiratory volume in six seconds (FEV6) and FEV1/FEV6 ratio, an acceptable surrogate for FVC for the spirometric diagnosis of obstruction [18].”
Method
Metadata
- Authors
- SWANNEY, M. P., JENSEN, R. L., CRICHTON, D. A., BECKERT, L. E., CARDNO, L. A., & CRAPO, R. O.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-09-01
- Volume
- 162
- Issue
- 3
- Pages
- 917-919
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2162513262
- Cited by
- 196
- References
- 0
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.